The instrument is suitable for various diagnosis, examination and general microscope operation. Due to 

its  flexible  and  stable  structure  and  easy  operation,  the  instrument  can  be  widely  used  for 

micro-operation  in  dental  especially,  and  also  can  be  used  for  micros-operation  in  ophthalmology, 

ear-nose-throat, gynecology and surgery. 

 

The Environment For Use 
 

a) Transport and Storing 
● Ambient Temperature Range: -40

-55

 

● Relative Humidity Range: 10%-80% 
● Barometric Pressure Range: 500 hPa-1060 hPa 
b) Operation 
● Ambient Temperature Range: 5

-40

 

● Relative Humidity Range: 30%-80% 
● Barometric Pressure Range: 700 hPa-1060 hPa2 
 

1. Precautions 

1.1 

After  unpacking  the  carton,  check  the  parts  against  the  packing  list  first.  If  there  is  any 

difference, contact the sales department to protect your benefit. 

1.2 

When carrying and unpacking the carton, pay attention that the arrow on the carton shall be at 

upward position. Handle the instrument with care to prevent it from being damaged.   

1.3 

The instrument shall be used and kept in a clean and dry place with constant temperature in 

order to ensure the lifetime of the component in the instrument. Before using the instrument, 

make sure to step down the brake on the foot wheel to prevent the instrument from sliding to 

avoid accident. When moving the instrument in the room, it is recommended to push it at the 

lower part to prevent the instrument from being upset and damaged.   

1.4 

Do not touch the surface of the lens and prism with hand or hard objects.   

1.5 

When the LED bulb is broken and has to be replaced, make sure that the power is off and the 

bulb is fully cool down in order to prevent your finger from being hurt. Never touch the glass 

surface of the illumination bulb (LED bulb) with your finger directly. If the bulb surface is found 

oily and dirty, it shall be cleaned with flannelette soaked with alcohol before usage.   

1.6 

The counterweight of the base of the instrument is limited. When the arm is stretched, never 

press  the  instrument  with  strong  force.  Otherwise,  the  instrument  can  go  down  to  get  the 

operator or the instrument itself damaged.   

1.7 

Before using the instrument, make sure the connecting parts are fastened or adjusted to right 

position to avoid accident caused by the failure of the parts.   

1.8 

Never move any part of the instrument with strong force. Adjustment shall be done according 

to the instruction, especially for the operation handle, it shall not be turned with over force to 

prevent it from impacting the arm to get the components damaged.   

1.9 

Power  shall  be  switched  off  after  using  the  instrument.  After  use,  the  instrument  shall  be 

cleaned and covered with plastic cover to prevent dust. 

 

2. Main Technical Data 

 

2.1  Input voltage: AC100-240V, frequency: 50HZ-60HZ 

Summary of Contents for A41.1903

Page 1: ...safety and obtain satisfactory performance please study this instruction manual thoroughly before start to use your instrument A41 1903 Operating Microscope One Head 0 180 Manual Step Zoom 4 8x 16x F...

Page 2: ...agnification change Fine focusing can be done by objective fine adjusting lever Two objectives are available for different working distance and magnification The illumination system of the instrument...

Page 3: ...ng to avoid accident When moving the instrument in the room it is recommended to push it at the lower part to prevent the instrument from being upset and damaged 1 4 Do not touch the surface of the le...

Page 4: ...5 Diameter of Spot 57 00 mm 71 00 mm 86 00 mm 113 00 mm Exit Pupil Distance 25 00 mm 2 4 Table of Specification for A41 1903 Operation Microscope Model A41 1903 Binocular Head Tilting 0 180 Main Usag...

Page 5: ...6 Arm assembly 7 0 180 Binocular 8 Eyepiece 9 CCD camera optional 10 Demonstrator optional 11 Beamsplitter optional 12 Magnification changer 13 Video camera adapter optional 4 Working Principle and Fu...

Page 6: ...socket for camera 6 Brightness control knob 7 Power switch Note Non professional maintenance staffs do not open the power supply box 4 3 Arm assembly see Figure 1 The arm assembly is an important part...

Page 7: ...r which connects with beamsplitter 3 Focusing hand wheel 4 Locking screw8 c Demonstrator 10 optional It is a monocular observation unit connected to the beamsplitter It can be used for observation at...

Page 8: ...objective you need Turn fine focusing lever counterclockwise to make the fine focusing lever in the middle position 5 7 Installation of operation handle Fix the operation handle on the head of micros...

Page 9: ...peat step 7 3 7 5 Step down the foot wheel brake during operation to present the instrument from being moved 8 Care and Maintenance The instrument shall be placed in a dry dust free and well ventilate...

Page 10: ...on does not light The LED lamp is not connected correctly Connect again No switch on the main power Switch on the main power Main power is broken down Contact a local electrician Electric parts are br...

Page 11: ...t LED lamp plug into the DC output socket 11 3 Remove four screws in red circle open under cover from power supply box Press the plug connectors in LED drive circuit board and repeat step 2 If not DC...

Page 12: ...connection of power line from power supply box to LED bulb If yes please replace LED bulb 11 6 If you have two operation microscopes in your hand you can cross check for example install this microscop...

Page 13: ...ose wire clip C Remove two screws fixed LED bulb and separate LED bulb from LED bulb seat Welding off two electric wire from LED bulb and remember the welding position for each electronic wire Weld tw...

Page 14: ...ter optional 1 pc 4 CCD camera optional 1 pc 5 Demonstrator optional 1 pc 6 Objectives F 200mm fitted on the microscope 1 pc F 250mm 1 pc F 300mm optional 1 pc F 400mm optional 1 pc 7 Power supply box...

Reviews: