OptiPure ScaleX2 SX2-21 Installation, Operation & Maintenance Manual Download Page 4

Replacement Parts for:  
SX2-21, SX2-22

Part #

Description

600-10050

Sump, 10”

600-10060

Sump, 20”

600-99003

O-Ring -Std

520-00206

Valve, Inlet Ball 1/2”

530-20019

Gauge, Pressure 0-160 psi

600-99007

Wrench, Std.

600-99205

Pressure Relief Button Kit

160-52910

(Optional) Flush Valve Kit 1/2” 

Replacement Filter Cartridges

OptiPure Filter Systems are designed, tested, and certified with OptiPure filter cartridges with proven performance, 

size and operating capacities.  Use of replacement cartridges other than those specified will void warranties and 

certifications, and may compromise equipment protection, water quality and cartridge life.  

Models SX2-21, SX2-22 Tested and Certified 

by NSF International against NSF/ANSI 

Standard 42 for the reduction of:
Standard 42: Aesthetic Effects

Chlorine

Taste and Odor

Particulate Reduction: Class 1

The ScaleX2

®

 Cartridge in the SX2 Series 

Systems is tested and certified by NSF 

International against NSF/ANSI Standard 42 for 

material requirements only.

NOTE:  Testing was performed under standard labora

-

tory conditions, actual performance may vary.  It is 

recommended that you have your water supply tested 

to determine your actual water conditions.

For further information regarding OptiPure Certified 

systems visit the NSF website at www.NSF.org

Replacement Cartridges 

System

Cartridge

Qty

SX2-21

CTO-10

SCLX2-1

1

1

SX2-22

CTO-20

SCLX2-2

1

1

OptiPure warrants the quality of workmanship of their 

system components and assembly, except for replace

-

ment cartridges and membranes, for a period of 60 

months. OptiPure Systems are designed, tested and 

certified with OptiPure cartridges.  Use of replacement 

cartridges or parts other than those specified will void 

warranties and certifications, and may compromise 

equipment protection, water quality and cartridge life.  

OptiPure, a division of AQUION

2605 Technology Dr., Bldg 300 Plano, TX 75074

p: 972.881.9797;  f: 972.422.6262 

e: [email protected]   

www.optipurewater.com

©2017 Aquion, Inc. 

SX2-21,-22   11/3/17

4

Summary of Contents for ScaleX2 SX2-21

Page 1: ...tion and performance The OptiPure System is built with the finest and most advanced materials Each system is quality inspected and pressure tested prior to shipment With proper installation and routine maintenance you should have years of trouble free operation Please refer to this manual when performing routine filter changes The instructions make periodic maintenance quick and easy and ensure th...

Page 2: ...inlet valve closed slowly open the 1 2 full flow ball valve at the tap water source Check for leaks 8 If a drain valve was not installed on the outlet side of the system hold the tubing that will connect to equipment in a clean bucket or over sink or drain Open the system inlet feed valve and allow water to flush through system for ten 10 minutes at the specified system flow rate to allow air and ...

Page 3: ...hold bleach in a filter bowl of water Let stand 5 minutes and then discard 6 Insert new cartridges into filter housings Match cartridge model numbers to model numbers on bracket 7 Make certain the O ring is properly positioned and reinstall filter housings hand tighten only Check O ring for damage and replace if damaged or distorted 8 Slightly open the inlet ball valve push the red pressure relief...

Page 4: ...nd certified by NSF International against NSF ANSI Standard 42 for material requirements only NOTE Testing was performed under standard labora tory conditions actual performance may vary It is recommended that you have your water supply tested to determine your actual water conditions For further information regarding OptiPure Certified systems visit the NSF website at www NSF org Replacement Cart...

Reviews: