OptiPure ScaleX2 SX2-21 Installation, Operation & Maintenance Manual Download Page 3

Operation

With adequate pressure, normal operation of the ScaleX2

®

 System is completely automatic.  Dependable operation 

involves only monitoring of outlet pressure, periodic filter changes and service documentation.

Pressure Gauge Monitoring

Periodically monitor the pressure gauge on the ScaleX2

®

 unit.  If the needle on the gauge ever enters the red zone, it 

may be an indication that the filters have become clogged with sediment.  Ideally, the pressure should never drop into 

the red zone.  

Filter Change Frequency

Several situations will mandate filter changes.  Complete filter sets should be 

changed when any of the following apply:

•    Six (6)  to twelve (12) Months have passed since unit installation or previous 

filter change.

•    Reduced water flow.
•    Pressure gauge needle enters the red zone or drops below pressure required 

for equipment operation.

  If filter change frequency is less than 6 months due to pressure drop, it may 

be necessary to add additional prefiltration or evaluate system sizing recom

-

mendations.  

Filter Cartridge Replacement Procedure

IMPORTANT:  Determine whether all equipment connected to the ScaleX2

®

 System 

must be turned off prior to shutting off water supply from filters.  

1.  If required, turn off equipment.

2.  Turn OFF water to ScaleX2

®

 System by closing Inlet Ball Valve.

3.  Press the red button to release pressure.
4.  Remove housing(s) - use filter wrench if necessary.  

5.  Clean inside of housing sumps with warm water.  If desired, disinfect hous-

ings using a teaspoon of household bleach in a filter bowl of water.  Let 

stand 5 minutes, and then discard.

6.  Insert new cartridges into filter housings.  Match cartridge model numbers 

to model numbers on bracket.

7.  Make certain the O-ring is properly positioned and reinstall filter housings 

(hand tighten only). Check O-ring for damage and replace if damaged or 

distorted.

8.  Slightly open the inlet ball valve; push the red pressure relief button to 

release trapped air until a small amount of water comes out - release the 

red button and fully open the ball valve.

9.  Open the flush valve downline from the filter housing (if equipped) and 

flush the new cartridges to drain or bucket for ten (10) minutes or until wa

-

ter runs clear.  If no flush valve is present, disconnect line from equipment 

to flush to drain.

10.  VERY IMPORTANT: With water supply inlet valve OPEN and water flow 

confirmed, turn on connected equipment.  Failure to supply water to equip

-

ment may cause serious damage.

11.  Record filter change.

2.

3.

8.

6.

7.

4.

Maintenance

The only routine maintenance your ScaleX2

®

 System should ever require is periodic filter cartridge changes or 

replacement sump O-rings.  Filter changes are necessary for optimum performance of your foodservice equipment.  If 

the system sizing recommendations have been followed, the ScaleX2

®

 System is designed to provide a six (6) month 

filter- replacement interval on most tap water for the CTO-20 cartridge, and the ScaleX2

®

 Cartridge should last one (1) 

year..  

10.  Connect tubing to equipment. Open all water supply valves and check for leaks.
11.   If there are no leaks, turn on equipment and check for normal operation.
12.  Attach the Service Log to the Installed OptiPure System and fill in install date.

3

Summary of Contents for ScaleX2 SX2-21

Page 1: ...tion and performance The OptiPure System is built with the finest and most advanced materials Each system is quality inspected and pressure tested prior to shipment With proper installation and routine maintenance you should have years of trouble free operation Please refer to this manual when performing routine filter changes The instructions make periodic maintenance quick and easy and ensure th...

Page 2: ...inlet valve closed slowly open the 1 2 full flow ball valve at the tap water source Check for leaks 8 If a drain valve was not installed on the outlet side of the system hold the tubing that will connect to equipment in a clean bucket or over sink or drain Open the system inlet feed valve and allow water to flush through system for ten 10 minutes at the specified system flow rate to allow air and ...

Page 3: ...hold bleach in a filter bowl of water Let stand 5 minutes and then discard 6 Insert new cartridges into filter housings Match cartridge model numbers to model numbers on bracket 7 Make certain the O ring is properly positioned and reinstall filter housings hand tighten only Check O ring for damage and replace if damaged or distorted 8 Slightly open the inlet ball valve push the red pressure relief...

Page 4: ...nd certified by NSF International against NSF ANSI Standard 42 for material requirements only NOTE Testing was performed under standard labora tory conditions actual performance may vary It is recommended that you have your water supply tested to determine your actual water conditions For further information regarding OptiPure Certified systems visit the NSF website at www NSF org Replacement Cart...

Reviews: