OptiPure ScaleX2 SX2-21 Installation, Operation & Maintenance Manual Download Page 1

Installation, Operation & Maintenance Manual

Reduce Particulate, Chlorine, Taste, Odor & Scale

 For ScaleX2

® 

Models:  SX2-21, SX2-22

DO NOT DISCARD - GIVE THIS MANUAL TO THE OWNER AFTER INSTALLATION

DO NOT DISCARD THIS MANUAL AFTER INSTALLATION.  THIS MANUAL CONTAINS IMPORTANT OP-

ERATION, MAINTENANCE AND PRECAUTIONARY INFORMATION.  PLEASE PRESENT THIS MANUAL TO 

USER/OPERATOR/OWNER AFTER INSTALLATION.
IT IS STRONGLY ENCOURAGED THAT YOU READ THIS MANUAL BEFORE INSTALLING SYSTEM TO 

ENSURE THE BEST POSSIBLE INSTALLATION.
INSTALLATION MUST CONFORM TO ALL LOCAL AND STATE PLUMBING CODES AND REGULATIONS.
CONNECT SYSTEM TO COLD WATER SUPPLY ONLY. WATER TEMP. CAN NOT EXCEED 100°F/38°C.

SYSTEM MUST BE INSTALLED IN A VERTICAL AND UPRIGHT POSITION.
SCALEX2

®

 SYSTEMS MUST NOT BE USED IN CONJUNCTION WITH POLYPHOSPHATE OR ANY OTHER 

SCALE INHIBITOR.
DO NOT INSTALL FILTERS DOWNLINE FROM THE SCALEX2

®

 SYSTEM. SCALEX2

®

 MUST BE THE LAST 

FILTER SYSTEM BEFORE THE EQUIPMENT.

DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY WITH-

OUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.
FAILURE TO CHANGE CARTRIDGES PER RECOMMENDED INTERVALS WITH OPTIPURE REPLACE-

MENT CARTRIDGES MAY LEAD TO SYSTEM FAILURE AND PROPERTY DAMAGE.

Introduction

Your new OptiPure ScaleX2

®

 FoodService Filtration System will cleanse and condition the tap water, providing opti-

mum water characteristics for specified applications.  Results include reduced equipment-maintenance requirements, 

longer equipment life and improved quality and consistency of your products.  Proper system installation and routine 

filter changes ensure years of trouble-free operation and performance.
The OptiPure System is built with the finest and most advanced materials. Each system is quality inspected and 

pressure-tested prior to shipment.  With proper installation and routine maintenance, you should have years of 

trouble-free operation.
Please refer to this manual when performing routine filter changes. The instructions make periodic maintenance quick 

and easy, and ensure that you should receive maximum benefit from your system.

System Specifications

Maximum Pressure:  125 psi/8.6 bar  

Maximum Temperature:  100°F/38°C, Min.: 35°F/2°C

Capacity:  Change the CTO (pre-filter) cartridge at gallon rating, or at least every 6 months or when pressure gauge 

needle enters the red zone on the outlet gauge while water is flowing through the filter system under normal operating 

conditions. The SCLX2 cartridge does not have a grain removal capacity; however, naturally occurring organics pres-

ent in the water will gradually degrade the effectiveness of this cartridge. Change the SCLX2 cartridge at least once 

a year.

Installation Precautions

•  Do NOT install system on line pressure above 125 psi.
•  Do NOT install the system backwards with the feed water line connected to the outlet.
•  Do NOT use liquid pipe compounds for fitting connections.  USE two to three wraps of teflon tape.
•  Do NOT solder plumbing connections attached to filter housing or inlet valve.  Inlet valve and filter housing will                     

be damaged by high temperature.

• 

Do NOT allow system to freeze. Turn off water supply to housing and drain housing if temperature falls below 32°F.

•  Do NOT install system in direct sunlight or where system is exposed to harsh chemicals, or where it may be  

subjected to being struck by moving equipment, carts, mops or any other item that may cause damage.

•  ALLOW a minimum of 3” under the housing to allow for filter replacement.

Summary of Contents for ScaleX2 SX2-21

Page 1: ...tion and performance The OptiPure System is built with the finest and most advanced materials Each system is quality inspected and pressure tested prior to shipment With proper installation and routine maintenance you should have years of trouble free operation Please refer to this manual when performing routine filter changes The instructions make periodic maintenance quick and easy and ensure th...

Page 2: ...inlet valve closed slowly open the 1 2 full flow ball valve at the tap water source Check for leaks 8 If a drain valve was not installed on the outlet side of the system hold the tubing that will connect to equipment in a clean bucket or over sink or drain Open the system inlet feed valve and allow water to flush through system for ten 10 minutes at the specified system flow rate to allow air and ...

Page 3: ...hold bleach in a filter bowl of water Let stand 5 minutes and then discard 6 Insert new cartridges into filter housings Match cartridge model numbers to model numbers on bracket 7 Make certain the O ring is properly positioned and reinstall filter housings hand tighten only Check O ring for damage and replace if damaged or distorted 8 Slightly open the inlet ball valve push the red pressure relief...

Page 4: ...nd certified by NSF International against NSF ANSI Standard 42 for material requirements only NOTE Testing was performed under standard labora tory conditions actual performance may vary It is recommended that you have your water supply tested to determine your actual water conditions For further information regarding OptiPure Certified systems visit the NSF website at www NSF org Replacement Cart...