Step 7. When the process is complete, the DR01
screen will flash once and automatically return to the
operating screen.
Note: See "Current Value Calibration"
B. Handling the error message:
a) When the word "Sensor" and "
" symbol on
the main screen flash.
Cause: The reading head is too close to the tape.
Elimination: Please increase the head spacing and
press the button
2 times, then follow the
same procedure until step 6 to complete.
b) When the word "Sensor" and the "
" symbol
flash on the main screen.
Cause: The reading head is too far away from the tape
Elimination: Please reduce the head spacing.
Then press the button
2 times, then follow the
same procedure until step 6 to complete.
c. If you move too slowly, the main screen will still be
on Go or Go- Go—
Cause: The read head is too far away from the tape or
the mechanical flatness is not flat enough.
Elimination: Improve the mechanical flatness or reduce
the head spacing.
d. To interrupt or exit the error handling process, press
to return to the original operation screen.