OPTIMUM
M A S C H I N E N - G E R M A N Y
Installation
Version 1.0 dated 2015-03-31
Page 15
Original operating instructions
DPA22
GB
Check the orientation of the reading head using a dial gauge.
The parallel error between the orthogonal side surfaces of the measuring gib and the
machine-tool guide must be less than 0.2mm across the entire range.
The maximum gap between the two parallel surfaces of the measuring gib and the sensor
head is 1.2 to 1.5mm.
After installation of the measuring gib, remove the plastic support.
Img.2-10:
2.7.3 Trouble shooting
Below are some typical errors which may occur during installation and operation:
The value shown on the display does not correspond to the actual value because the
parameter setting for the counting resolution is set improperly.
Reading head is incorrectly connected. Check connection
The gap tolerance between measuring head and measuring gib was not maintained across
the entire measurement range
Cable squeezed / interrupted / cut by sharp edges.
Moisture has penetrated extension cable plugs.
Travel speed is too high; it should not exceed 0.5 meters per second.
The replacement measuring gib is not from the same manufacturer as the original measur-
ing gib. The actual counting resolution of the measuring gib does not correspond to the set
value.
The input signal on the Digital Position Indicator is not set to 11 uApp.
Plastic support
Plastic support
1.
2 -
1
.5
0.2
0.2