OPTIMUM
M A S C H I N E N - G E R M A N Y
Operation
Version 1.0 dated 2015-03-31
Page 18
Original operating instructions
DPA22
GB
When a higher representational accuracy value
is set on the display than the actual
counting resolution, the representational accuracy value will be shown accordingly.
Correction factor:
Linear error compensation coefficient. The value range for linear error compensation coeffi-
cients extends from -9.999 to 9.999mm, and gives the value to be adjusted per meter.
Number of impulses per revolution
the set value of the number of pulses per revolution of the revolution speed signal The number
of impulses per revolution of the revolution speed signal depends on the number of output
pulses per revolution of the transducer in use (i.e. rotational speed disc). The greater this value
is, the higher will be the resolution of the revolution speed. The range of possible setting values
extends from 1 to 3600.
Measurement time:
the set value of the time for speed measurement
The maximum set value is 10 (i.e. 1 second) and the minimum set value is 1 (i.e. 0.1 second).
The greater this value is, the higher will be the resolution of the revolution speed, and the
slower this value will be refreshed.
The representational accuracy of the rotational speed indicator shown directly on the display =
600 / (number of impulses per revolution x measurement time)
1
4
Factory settings:
Where delivered as a standalone device.
In applied delivery state with machine tool.
Please record the values before making any changes.
= 0.005mm
=
= 0
=
= 0.005mm
=
= 0.000mm
=
=
=
1
1
2
2
3
3
4
4
5
6
5
6