Machine substructure
Version 1.0 dated 2019-09-04
Page 8
Translation of the original instructions
MST1
GB
machine-
base_3
44040
9_G
B.f
m
OPTIMUM
M A S C H I N E N - G E R M A N Y
®
2.2
Assembly and installation
2.2.1
Anchor-free assembly
This must be done by laying down a strong base on each support of the levelling points,
between the foundation and the machine foot.
2.2.2
Installation with levelling discs
Optional levelling discs
Attaching of 6 pieces SE1 levelling disc on levelling
points between the foundation and machine stand.
Dimension of levelling discs
2.2.3
Installation with vibration dampers
Optional vibration dampers
Attaching of 6 pieces SE55 vibration dampers on levelling
points between the foundation and machine stand.
In order to obtain optimum anti-slip protection, the subfloor
must be free of oil and grease before the machine or sys-
tem is installed.
CAUTION!
The max. load per element refers to the sum of static
plus dynamic forces. The machine must not be moved after the machine has been
lowered!
Jackscrew
Counternut
A
B
C
D
E
A
B [mm]
C [mm]
D [mm]
E [mm]
SE1
M12
70
10
32
120
SE2
M16
90
12
35
160
SE3
M20
130
12
40
185