10
ventilation and to access cable connectors. Consider following steps to install the RPS
system on a flat surface.
Set the RPS Power Series RPS on the flat surface and check for proper ventilation
and air flow.
Allow at least 2 inches (5.1 cm) on each side for proper ventilation and 5 inches
(12.7 cm) at the back for AC and DC power-cord clearance.
Attach rubber feet on the bottom of the chassis to keep the unit from slipping.
Installing the RPS Power Supply in a Rack
The RPS Power Supply can be installed in most standard 19-inch racks. Consider
following steps to install RPS Power Series RPS in rack.
Use appropriate size screws to attach the RPS system to the 19-inch rack.
Position the RPS Power Series RPS in the rack and align the oval shaped holes on
the side of the RPS with the holes in the rack.
Insert and tighten two screws appropriate for your rack through each of the oval
shaped holes on the side of the RPS.
To Operate the RPS Power Supply after Installation
Model RPS5412 may be installed in environments that meet the environmental
characteristics specified in Chapter 2.
It is recommended that sufficient ventilation gap be
provided above or below the RPS unit for proper air flow.
Once the RPS (redundant power supply) is mounted in the rack, it should be connected to
a switch
(that only requires –52VDC or +12VDC power)
,
and has a DC connector
located on rear panel as shown:
The figure shows where to connect the Optimal Power® RPS Model RPS5412 on the
NETGEAR® switch.
Note: The location of the redundant power supply connector on your switch may differ from
the illustration
.
RPS
DC Connector on NETGEAR®
switches for Optimal Power
®
RPS
Power Supply Series
™ RPS
DC Connector on the
switches is behind a
metal cover plate
NETGEAR® Switch
RPS Connector