OPTIKON I.V. Installation And Operating Manual Download Page 9

I.V. Pole cart 

Installation and operating manual 

OPTIKON 2000 

Code 181004EN 

 

2007-10-09 Rev. 0 

 

3-1

3. WARNINGS

 

Care in the handling of surgical equipment and instruments is one of the first 
principles in an operating-room, and no amount of warnings can take place of such 
care. 
 

NOTE: THIS INFORMATION IS BELIEVED TO BE CURRENT AT THE TIME 
OF PUBLICATION, BUT IS PROVIDED WITHOUT WARRANTY OF ANY 
KIND AND WE ASSUME NO RESPONSIBILITY WITH RESPECT THERETO.

 

 

The following warnings will aid the user to provide adequate safeguards to assure 
safe, trouble free performance: 

• 

ALL MEDICAL PERSONNEL SHOULD READ AND UNDERSTAND THE 

INSTRUCTIONS IN THIS MANUAL AND THE MANUAL OF THE 
EQUIPMENT CONNECTED TO THE CART PRIOR TO THE SYSTEM IS 
USED. DO NOT ATTEMPT TO USE THE SYSTEM IF IT FAILS TO 
PERFORM AS SET OUT IN THE OPERATION PROCEDURES, IN THESE 
MANUALS. 

• 

USE OF THE SYSTEM SHOULD BE RESTRICTED TO QUALIFIED 

MEDICAL PERSONNEL. 

• 

USE OF THIS SYSTEM IS A MATTER OF PROFESSIONAL MEDICAL 

JUDGMENT IN ALL CASES. OPTIKON 2000 S.p.A. IS NOT RESPONSIBLE 
FOR ANY CLINICAL PROBLEM RESULTING FROM MISHANDLING THIS 
INSTRUMENT AND MAKES NO MEDICAL RECOMMENDATIONS. 

• 

THE SYSTEM SHOULD NEVER BE USED IN THE PRESENCE OF 

FLAMMABLE ANAESTHETICS, DISINFECTING AGENTS, CLEANING 
AGENTS, ETC., DUE TO POSSIBLE FIRES OR EXPLOSION. 

• 

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER 

(OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL 

• 

THE "OPTIKON EQUIPMENT CART" SHOULD BE CONNECTED TO A 

MAINS SUPPLY ONLY AS MARKED ON THE REAR PANEL. TO 
GUARANTEE SAFETY, A HOSPITAL GRADE POWER CORD AND PLUG 
MUST BE USED, THE UNIT MUST BE GROUNDED. USE EXCLUSIVELY 
THE MAINS POWER CABLE PROVIDED OR A CABLE THAT IS IN 
COMPLIANCE WITH SAFETY REGULATIONS. 

• 

FOR OPERATING SAFETY DO NOT INSTALL THE SYSTEM IN A 

LOCATION WHERE IT WILL BE EXPOSED TO HEATING EQUIPMENT OR 
RADIATORS. DIRECT SUNLIGHT AND ANY OTHER SOURCE OF 
EXTREMELY HIGH TEMPERATURES. 

• 

BE SURE THAT THE POWER SWITCH ON THE LEFT SIDE OF THE CART 

IS OFF WHEN PLUGGING IN, OR REMOVING THE POWER CABLE FROM 
A WALL OUTLET.  TURN OFF THE MAIN POWER SWITCH WHENEVER 
THE EQUIPMENT IS NOT IN USE. 

Summary of Contents for I.V.

Page 1: ...Rev 0 EQUIPMENT CART WITH ELECTRIC I V POLE INSTALLATION AND OPERATING MANUAL OPTIKON 2000 S p A Via del Casale di Settebagni 13 00138 Rome Italy Tel 39 06 88884355 Fax 39 06 8888440 e mail sales opt...

Page 2: ...O 9001 and ISO 13485 certified company that manufactures surgical and diagnostic devices for ophthalmology All OPTIKON 2000 products are manufactured in compliance with the requirements of Directive 9...

Page 3: ...ATION 5 1 5 1 SYSTEM DESCRIPTION 5 1 5 2 CONTROLS AND INDICATORS 5 1 5 3 TECHNICAL SPECIFICATIONS 5 3 5 4 CIRCUIT DIAGRAMS 5 4 6 INSTALLATION AND OPERATING PROCEDURE 6 1 6 1 INTRODUCTION 6 1 6 2 INITI...

Page 4: ...THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 5: ...f updates calibrations and repairs are carried out by personnel which has been authorised by OPTIKON 2000 S p A the system is used in compliance with the user instructions the mains electric installat...

Page 6: ...I V Pole cart Installation and operating manual OPTIKON 2000 Code 181004EN 2007 10 09 Rev 0 1 2 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 7: ...made by persons who are not part of the authorised OPTIKON S p A technical service OPTIKON 2000 S p A reserves the right to verify in case of failures if the instrument and or its accessories have be...

Page 8: ...I V Pole cart Installation and operating manual OPTIKON 2000 Code 181004EN 2007 10 09 Rev 0 2 2 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 9: ...OF PROFESSIONAL MEDICAL JUDGMENT IN ALL CASES OPTIKON 2000 S p A IS NOT RESPONSIBLE FOR ANY CLINICAL PROBLEM RESULTING FROM MISHANDLING THIS INSTRUMENT AND MAKES NO MEDICAL RECOMMENDATIONS THE SYSTEM...

Page 10: ...UM OF APPROX 235cm OF HEIGHT DO NOT PLACE THE CART UNDER LOW CEILING DO NOT TILT THE CART MORE THAN 10 IN ANY DIRECTION TO AVOID RISK OF SMOKE OR FIRE WHEN PLUGGING HOSTED EQUIPMENT TO THE CART DO NOT...

Page 11: ...e The user should become acquainted to these symbols before using the equipment SYMBOL DESCRIPTION ALTERNATING CURRENT DIRECT CURRENT PROTECTIVE EARTH ATTENTION CONSULT ACCOMPANYING DOCUMENTS OFF POWE...

Page 12: ...I V Pole cart Installation and operating manual OPTIKON 2000 Code 181004EN 2007 10 09 Rev 0 4 2 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 13: ...dure An electric I V pole holds the BSS bottle to be used as irrigation source The bottle position height can be adjusted by the means of a rocker footswitch and or it can be controlled by the connect...

Page 14: ...een installed The following are located under the protection cover Fig 1 1 MAINS POWER CONNECTION FOR HOSTED CONSOLES Three mains sockets allow connecting the mains power for the hosted surgical conso...

Page 15: ...1 1 Classification Class I ELECTRICAL SPECIFICATIONS Input voltage 220 V 50 Hz 110 V 50 60 Hz Fuses 220 V 6 3 A T 110 V 16 A T IV Pole power consumption 40 VA Maximum connectable power 1 KVA I V POLE...

Page 16: ...2 Kg IMPORTANT NOTICE The footswitch is not autoclaveable The switches located inside the footswitch are immersion proof protection class IPX8 Therefore this accessory is suitable for use in operating...

Page 17: ...g instructions carefully in a step by step manner and within a short time you will have gained all the knowledge needed for successful operation of your surgery system 6 2 INITIAL INSPECTION This inst...

Page 18: ...n b Place the Optikon Console on the equipment tray c Remove the protection cover from the electric sockets by unscrewing the 4 socket head screws Removing the protection cover will give you access to...

Page 19: ...ole to the minimum height 2 Depress the Power switch on the rear of the cart column to power down the console and the cart 3 Disconnect the cart s cable from the power outlet and wrap it around the co...

Page 20: ...OTE OPTIKON 2000 S p A reserves the right to change design and specifications without notice because of its policy of continuous product research and development CAUTION DO NOT USE SYNTHETIC DETERGENT...

Page 21: ...OMS CORRECTIVE ACTION Mains power supply System completely inoperative a A C power cord not connected Connect power cord to the cart and the power source b A C line fuse blown Replace the line fuses c...

Reviews: