background image

Page  2

Description

The following assembly procedure can be used for the multidiscussion systems B-1000Ti-2, B-1000Ti-3, B-

1000Ti-5 and B-1000Ti-10. The assembly sequence is identical for all systems.

The microscope is a precision scientific instrument designed for long lasting life with a minimal maintenance, be

-

ing built following the best optical and mechanical standards and developed for a daily use. Optika reminds that 

the present manual contains important informations for a safe use and a correct maintenance of the instrument. 

It has to be available for each user.

Optika declines any responsibility deriving from instrument uses that do not comply with this manual.

Unpacking and assembly

The multidiscussion system is housed in a moulded Styrofoam container. Remove the tape from the edge of 

the container and lift the upper part of the container. Take care not to let optical items fall out end get damaged. 

Remove each part from the housing and place them of a sturdy table.

2.1 

Install the microscope body as indicated in the specific instruction manual. 

 

Do not install the observation head.

2.2

 

Place the splitter attachment of the multidiscussion system and tighten the lock screw on the right side 

 

of the microscope (Fig. 1).

2.3

 

In order to use the arrow which will be used as a pointer, connect the 5Vdc power supply to the rear Jack 

of the splitter attachment. (Fig. 2). Now use the pointer position controller (1) or the pointer intensity con-

troller (2) to adjust the position and intensity of the pointer.

POINTER POSITION CONTROLLER (1)

POINTER INTENSITY CONTROLLER (2)

Fig. 2

Fig. 1

Summary of Contents for B-1000Ti-10

Page 1: ...Version 2 Issued 16 02 2015 Model B 1000Ti 2 B 1000Ti 3 B 1000Ti 5 B 1000Ti 10 B 1000 Series INSTRUCTION MANUAL...

Page 2: ...mbly The multidiscussion system is housed in a moulded Styrofoam container Remove the tape from the edge of the container and lift the upper part of the container Take care not to let optical items fa...

Page 3: ...Repeat the same procedure on the other side of the splitter 2 6 Insert the second part of the extension tube Fig 6 At the end of the first extension tube there is a lens Fig 5 Make sure it is free fro...

Page 4: ...ck the knob Fig 7 Make sure that each extension tube is perfectly horizontal 2 9 Insert the optical head always matching the refer ence letters and screw the black fixing ring Fig 8 2 10 Insert the bi...

Page 5: ...plitter attachment over the pointer attachment then fix the extension tube rotating the black ring nut always following the coupling catters Fig 11 and Fig 12 2 14 only B 1000Ti 10 repeat for the 5 ba...

Page 6: ...Page 6 Fig 14 Fig 15 2 15 Install the trinocular head over the splitter directly onto the microscope body Fig 14 2 16 Once completely assembled the B 1000Ti 5 looks like this...

Page 7: ...Versi n 2 Publicado 16 02 2015 Modelos B 1000Ti 2 B 1000Ti 3 B 1000Ti 5 B 1000Ti 10 Serie B 1000 MANUAL DE INSTRUCCIONES...

Page 8: ...ste manual Desembalaje y montaje El sistema multi discusi n se suministra embalado dentro de una caja de poliestireno Porexpan moldeado Retire la cinta que rodea la caja y levante la tapa superior Ten...

Page 9: ...con el otro lado del m dulo divisor 2 6 Inserte la segunda parte del tubo de extensi n fig 6 Al final del primer tubo de extensi n hay una lente fig 5 Aseg rese de que est libre de suciedad polvo u o...

Page 10: ...se de que cada tubo de extensi n esta perfectamente en horizontal 2 9 Inserte el cabezal ptico siempre teniendo en cuenta que coincidan las letras de los tubos para una posici n correcta y el tornillo...

Page 11: ...puntero luego f je el tubo de extensi n giran do el aro de color negro siempre sigui ndo las letras correspondientes Figuras 11 y 12 2 14 solo para B 1000Ti 10 repita el mismo procedimiento de montaj...

Page 12: ...P gina 12 Fig 14 Fig 15 2 15 Inserte el tubo trinocular al cabezal del microscopio principal figura 14 2 16 Una vez el equipo est completamente ensamblado el modelo B 1000Ti 5 se ver as...

Page 13: ...Versione 2 Datata 16 02 2015 Modello B 1000Ti 2 B 1000Ti 3 B 1000Ti 5 B 1000Ti 10 Serie B 1000 MANUALE D USO...

Page 14: ...osto in un imballaggio di polistirolo espanso preformato Rimuovere il nastro adesivo dall imballo e sollevare la parte superiore dell imballaggio Fare attenzione a non far cadere o danneggiare le comp...

Page 15: ...ere la stessa operazione sul lato opposto del deviatore 2 6 Inserire la seconda parte del tubo di estensione Fig 6 La parte terminale del primo di estensione chiusa da una lente Fig 5 Verificare che s...

Page 16: ...ola Fig 7 Assicurarsi che ciascun tubo di estensione sia perfettamente orizzontale 2 9 Inserire la testata ottica sempre facendo combac iare le lettere di riferimento e serrare l anello di tenuta nero...

Page 17: ...dispositivo per il puntamento poi fissare il tubo di estensione stringendo l anello nero di fissaggio sempre in corrispondenza delle lettere di riferimento Fig 11 e Fig 12 2 14 solo per B 1000Ti 10 ri...

Page 18: ...na 18 Fig 14 Fig 15 2 15 Installare la testata trinoculare principale sul deviatore ottico direttamente sopra il corpo del microscopio Fig 14 2 16 Completato l assemblaggio il B 1000Ti 5 si presenter...

Page 19: ...Pagina 19...

Page 20: ...s com www optikamicroscopes com OPTIKA Spain spain optikamicroscopes com OPTIKA USA usa optikamicroscopes com OPTIKA China china optikamicroscopes com OPTIKA Hungary hungary optikamicroscopes com DXPD...

Reviews: