INSTRUCTIONS FOR  

 

MODEL DC4-211 / 212 

 

COMPOUND BIOLOGICAL MICROSCOPE 

WITH DIGITAL CAMERA 

 
 
 

 
 

 

 

 
 
 
 
 
 
             
 
 

      

 

 

 
 

    

 

Copyright © 6/03/2016 

       National Optical & Scientific Instrument Inc.   

 

Summary of Contents for DC4-211

Page 1: ...nt Inc 6508 Tri County Parkway Schertz Texas 78154 Phone 210 590 9010 Fax 210 590 1104 INSTRUCTIONS FOR MODEL DC4 211 212 COMPOUND BIOLOGICAL MICROSCOPE WITH DIGITAL CAMERA Copyright 6 03 2016 Nationa...

Page 2: ...COMPONENTS 1 LED INDICATOR LIGHT Indicates if camera is on power supplied by USB 2 EYEPIECE ocular lens Lens closest to the eye magnifies the primary image formed by the objective lens 3 OBJECTIVE TUR...

Page 3: ...tical path making sure that lens is properly indexed in its click stop position B Swing moveable finger on slide holder outward Place specimen slide cover slip up on top of stage surface against fixed...

Page 4: ...r objective lenses to clean Clean only the outer lens surface Breath on lens to dampen surface then wipe with lens paper or tissue or use a cotton swab moistened with distilled water Wipe lenses with...

Page 5: ...ve 2 Follow the prompted instructions for installation 3 Each part of the installation will prompt you for a determined response 4 Unless you want to make changes to defaulted installation process all...

Page 6: ...mages is accessible within the software s main page To begin open the Motic Images Software At the top of main screen find the menu tab labeled Help Click on Help and then select the help option This...

Page 7: ...thin the live Imaging main page To begin open the Motic Images Software At the top of main screen find the menu tab labeled File and click on Capture Once the Motic Live Imaging Module has opened clic...

Page 8: ...ront lens of the objective Dirt on the upper lens of the condenser Dirt on the surface of the sample slide glass Dirt on the upper lens of illuminator Dirt on other optical components of the microscop...

Page 9: ...the entire surface of the microscope Take special care with the electrical components of the microscope such as the ON OFF switch the dimmer the lamp holder If there are grease stains use the same cl...

Page 10: ...p too thick Use 0 17mm thick cover slip No 1 cover slip Poor resolution image not sharp Objective lenses dirty Clean objective lenses Eyepiece lens dirty Clean eyepiece lenses Too much light Adjust di...