background image

Opticon 

OPR 2001 

Specifications Manual 

 
 
 

 

27 

8.3.2. 

Connectors 

a) DOS/V 

Host 

Connector 

2

3

5

1

4

6

 

Figure 20: DOS/V host connector 

 

Contact Number

Signal Name 

1 CPU_DATA 

2 NC 

3 GND 

4 VCC 

5 CPU_CLK 

6 NC 

b) DOS/V Keyboard Connector 

4

6

3

5

1

2

 

Figure 21: DOS/V keyboard connector 

 

Contact Number

Signal Name 

1 KEY_DATA 

2 NC 

3 GND 

4 VCC 

5 KEY_CLK 

6 NC 

Do not use the keyboard while the scanner is transmitting the data to the host. 
Doing so may cause failure in data transactions. 

Summary of Contents for OPR 2001

Page 1: ...OPR 2001 Laser Barcode Scanner Specifications Manual ...

Page 2: ...ts that are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or incidental da...

Page 3: ...1 6 1 Laser Scanning Specifications 11 6 2 Laser Scanning Standard 11 6 2 1 Laser Scanning Tilt 11 6 2 2 Scanning Curvature 11 7 Technical Specifications 12 7 1 Print Contrast Signal PCS 12 7 2 Scan Area and Resolution 13 7 3 Pitch Skew and Tilt 14 7 3 1 Pitch Angle 14 7 3 2 Skew Angle and Dead Zone 15 7 3 3 Tilt Angle 16 7 4 Curvature 17 8 Interface Specifications 18 8 1 RS 232C Interface 18 8 1 ...

Page 4: ... Barcodes 30 10 2 Default Settings 1 Readable Codes 31 10 3 Default Settings 2 Read Options Trigger Buzzer 33 11 Serial Number 34 12 Packaging Specifications 34 12 1 Individual Packaging Specification 34 12 2 Collective Packaging Specification 34 13 Durability 35 13 1 Electrical Noise 35 13 2 Shock 35 13 2 1 Drop Test without packaging 35 13 2 2 Drop Test with individual packaging 35 13 3 Vibratio...

Page 5: ... 11 Figure 3 Depth of field 13 Figure 4 Pitch 14 Figure 5 Skew angle and dead zone 15 Figure 6 Tilt angle 16 Figure 7 Curvature 17 Figure 8 Interface circuit 19 Figure 9 Character format same for both sending and receiving 20 Figure 10 Communication format 20 Figure 11 No handshaking 20 Figure 12 Busy Ready communication 21 Figure 13 Cannot receive command 21 Figure 14 Signal timing 22 Figure 15 M...

Page 6: ...ons Manual 6 Figure 24 Wedge cable 29 Figure 25 Serial number diagram 34 Figure 26 Drop test 35 Figure 27 Cable tail bending test 36 Figure 28 Auto trigger operation 37 Figure 29 Trigger options 38 Figure 30 Mechanical drawing 42 ...

Page 7: ...an RS 232C USB or Wedge interface Auto trigger settings are available The OPR 2001 complies with RoHS Supported symbologies JAN UPC EAN all add on Chinese Post Matrix 2 of 5 Codabar NW 7 including ABC and CX Code 11 Code 39 Normal Code 39 Full ASCII Code 39 Italian Pharmaceutical Code 93 Code 128 EAN 128 Composite Codes UCC EAN 128 incl CC A B C IATA Industrial 2of5 Interleaved 2of5 ISBN ISMN ISSN...

Page 8: ...ons W 151 0 x D 56 0 x H 30 5 mm 3 2 Weight 60 grams max excluding cable weight 4 Environmental Specifications 4 1 Operating Temperature and Humidity Temperature 5 to 50 C Humidity 20 to 85 RH 4 2 Storage Temperature and Humidity Temperature 20 to 60 C Humidity 10 to 90 RH ...

Page 9: ...ght 3 000 lx Fluorescent light 3 000 lx Sunlight 50 000 lx Figure 1 Ambient light immunity Conditions Barcode Sample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Distance 70 mm Angle α 0 β 15 γ 0 Curvature R Power Supply Voltage 5 0 V Direct light or specular reflection light from a source should be prevented from entering the ac...

Page 10: ...Parameter Symbol Min Typ Max Unit Notes Power supply voltage VDD 4 5 5 0 5 5 V Operating current IOP 90 150 mA No buzzer Peak current IPEAK 450 500 mA Standby current IPRE 35 70 mA Startup time TD 100 ms Conditions Connect 1Ω resistance to a power supply line in series and measure the current by the voltage between both ends of resistance Power supply voltage is measured at a connector terminal ar...

Page 11: ...l difference between the ends of a laser scan line Up to 0 92 in a vertical direction from the scan origin mirror motor mirror Up to 2 46 mm when measured at 150 mm from the scan origin Measurement is done at the center of the laser scan line 6 2 2 Scanning Curvature Scanning curvature is the maximum difference between the laser scan line and the line between the ends of the laser scan line Up to ...

Page 12: ...21º C 70º F 60 RH Ambient light 500 to 900 lx Background Barcode black Space white Margin white Background of label black Power supply voltage 6 0 V RS 232C 5 0 V USB Wedge Decoding test Approve the performance when decoding is successful in all ten tests Decoding is deemed successful when completed in 0 5 seconds or less 7 1 Print Contrast Signal PCS 0 45 or higher over 70 of reflectivity of spac...

Page 13: ...gure 3 Depth of field Resolution Symbology PCS Quiet Zone Digits Depth of Field mm 1 0 mm CODE 39 0 9 25 mm 1 40 to 500 0 5 mm CODE 39 0 9 18 mm 3 20 to 350 0 25 mm CODE 39 0 9 10 mm 8 20 to 200 0 15 mm CODE 39 0 9 7 mm 10 20 to 100 0 127 mm CODE 39 0 9 5 mm 4 30 to 70 Conditions Barcode Sample OPTOELECTRONICS Test Sample N W Ratio 1 2 5 Angle α 0 β 15 γ 0 Curvature R ...

Page 14: ...Opticon OPR 2001 Specifications Manual 14 7 3 Pitch Skew and Tilt 7 3 1 Pitch Angle Scanning performance is guaranteed when α 35 Figure 4 Pitch ...

Page 15: ...anual 15 7 3 2 Skew Angle and Dead Zone Scanning performance is guaranteed when skew angle β 50 Excluding dead zone Dead zone β 8 There are some areas in which decoding fails due to specular reflection Figure 5 Skew angle and dead zone ...

Page 16: ...mm from the front edge of the scanner Label Pitch Skew Angle Dead Zone PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Tilt Angle PCS 0 9 Resolution 0 26 mm Symbology 13 digit JAN Quiet Zone 10 mm Angles Pitch angle Skew angle β 15 Tilt angle γ 0 Tilt angle Pitch angle α 0 Skew angle β 15 Skew angle Dead zone Pitch angle α 0 Tilt angle γ 0 Curvature R ...

Page 17: ...rmance is guaranteed when R 15 mm With 13 digit JAN UPC EAN barcodes decoding performance is guaranteed when R 20 mm Figure 7 Curvature Conditions Barcode Sample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 26 mm Quiet Zone 10 mm Distance 70 mm from the front edge of the scanner Angle Skew Angle β 15 ...

Page 18: ...ault Item U2 setting Baud rate 9600 BPS Start stop bits 1 bit Data bits 8 bits Parity bits No parity Handshaking No handshake Flow control time out Indefinitely You can change the communication condition using the menu barcode 8 1 2 Signal Level Signal Name I O RS 232C Level V Mark OFF Space ON TxD OUT 5 to 15 5 to 15 RxD IN 3 to 15 3 to 15 RTS OUT 5 to 15 5 to 15 CTS IN 3 to 15 3 to 15 ...

Page 19: ...pen not connected TXD 2 RXD 3 4 Connected to pin 6 with jumper cable GND 5 6 Connected to pin 4 with jumper cable CTS 7 RTS 8 NC 9 Open not connected FG SHELL Shield Connector D sub 9 pin Female Power supply DC jack EIAJ voltage Class 2 8 1 4 Interface Circuit Figure 8 Interface circuit ...

Page 20: ...n Format Figure 10 Communication format 8 1 7 Handshaking Select handshaking options using the menu or command listed below Handshaking Menu Command No handshake P0 BUSY READY P1 MODEM P2 ACK NAK P3 ACK NAK NO RESPONSE P4 a No Handshaking The scanner attempts the communication regardless of the state of the host computer Figure 11 No handshaking ...

Page 21: ...n parts of the process such as receiving data buzzer command execution transmitting data and menu processing The scanner checks the CTS line before transmitting data When it is ON the scanner transmits data When it is OFF the scanner waits for it to turn ON within a set time The scanner will abort transmission with an error indication buzzer when the CTS line is not ON within a specified period Th...

Page 22: ...and waits When the CTS signal is turned ON while transmitting a character the character will be transmitted Figure 14 Signal timing Note When using loopback wire connection for RTS CTS line of the scanner in this setting No handshake is not enabled c MODEM The scanner turns CTS line ON before transmitting data Other processes are the same as BUSY READY Figure 15 Modem transmit data ...

Page 23: ...l state NAK response Action The scanner sends the data again and waits for the response from the host DC1 response Action The scanner returns to waiting for the trigger if it has a trigger the initial state None response Action The scanner sounds the error buzzer and returns to the initial state ACK NAK timeout can be set as follows using the menu or commands ACK NAK Timeout Menu Command Indefinit...

Page 24: ... NAK NO RESPONSE When no response from the host is received within the setting time the scanner assumes an ACK response and returns to the initial state without the error buzzer The other actions are the same as ACK NAK Figure 17 ACK NAK No response ...

Page 25: ... The OPR 2001 USB model uses a full speed USB interface b USB VCP Reading menu barcodes ZZ C01 ZZ can set the USB VCP interface default The OPR 2001 USB model uses a full speed USB interface Note You must install the USB VCP driver on the host 8 2 2 Connectors a USB A connector 4 1 1 2 3 4 Figure 18 USB A connector Contact Number Signal Name 1 VCC 2 DATA 3 DATA 4 GND ...

Page 26: ...ata to the host Doing so may cause failure in data transactions 8 3 DOS V Wedge Interface Specification 8 3 1 Settings a Desktop PC When using external keyboard Reading menu barcodes ZZ UB KM ZZ can set the DOS V Wedge interface default b Notebook PC When not using external keyboard Reading menu barcodes ZZ UB KL ZZ can set the DOS V Wedge interface default ...

Page 27: ... Number Signal Name 1 CPU_DATA 2 NC 3 GND 4 VCC 5 CPU_CLK 6 NC b DOS V Keyboard Connector 4 6 3 5 1 2 Figure 21 DOS V keyboard connector Contact Number Signal Name 1 KEY_DATA 2 NC 3 GND 4 VCC 5 KEY_CLK 6 NC Do not use the keyboard while the scanner is transmitting the data to the host Doing so may cause failure in data transactions ...

Page 28: ...ght Diameter Φ4 8 0 5 mm Length 1500 50 0 mm Cores 6 insulated wires 1 conductive wire Weight Approximately 40 g Figure 22 RS 232C cable 9 2 USB Cable Standard specification Type Straight Diameter Φ4 8 0 5 mm Length 1500 50 0 mm Cores 4 insulated wires 1 conductive wire Weight Approximately 40 g Figure 23 USB cable ...

Page 29: ...0 0 mm Cores 6 insulated wires 1 conductive wire Weight Approximately 50 g Figure 24 Wedge cable 9 4 Connector Specification Scanner Side CN1 12 pin Pin No RS 232C USB Wedge 1 GND GND GND 2 RXD 3 TXD 4 CTS 5 RTS 6 NC 7 NC DATA KEY_CLK 8 NC DATA KEY_DATA 9 NC CPU_CLK 10 NC CPU_DATA 11 VCC VCC VCC 12 FG shield FG shield FG shield ...

Page 30: ...abels Menu codes SET _ZZ_ ZZ RS232C _U2_ U2 END _ZZ_ ZZ USB HID Default Functions Menu labels Menu codes SET _ZZ_ ZZ USB HID _SU_ SU END _ZZ_ ZZ USB VCP Default Functions Menu labels Menu codes SET _ZZ_ ZZ USB COM _C01_ C01 END _ZZ_ ZZ Wedge Default with external keyboard Functions Menu labels Menu codes SET _ZZ_ ZZ AT wedge default _UB_ UB With keyboard _KM_ KM END _ZZ_ ZZ ...

Page 31: ...adable Codes Symbology Read Transmit Code Length Transmit CD Calculate CD Set Prefix Set Suffix Others UPC A X CR UPC A Add on X X CR UPC E X CR UPC E Add on X X CR EAN 13 X CR EAN 13 Add on X X CR EAN 8 X CR EAN 8 Add on X X CR Chinese Post Matrix 2of5 X X X CR Code 11 X X X CR Code 39 X X CR Not transmit ST SP Code 39 Trioptic X CR Not transmit ST SP Code 93 X X CR Code 128 X X CR EAN 128 X X X ...

Page 32: ... 14 X X CR RSS limited X X CR RSS expanded X X CR S Code X X CR Telepen X X CR UK Plessey X CR Notes In the Reading column means Enable reading and X means Disable reading In the Transmit code length column means Transmit code length and X means Do not transmit code length In the Transmit CD column means Transmit check digit and X means Do not transmit check digit In the Calculate CD column means ...

Page 33: ...W setting Read n times redundancy n 1 for following symbologies and lengths Code39 with length 5 MSI Plessey with length 4 IATA Industrial 2of5 Interleaved 2of5 with length 8 Matrix 2of5 Chin Post Scode with length 8 Codabar NW7 with all lengths Code 11 with length 5 Trigger switch Enabled Trigger repeat Disable trigger repeat Auto trigger Disable auto trigger Margin check Margin check normal Buzz...

Page 34: ...ssembly 245 W x 110 D x 40 H mm 12 2 Collective Packaging Specification Put 50 individually packaged OPR 2001 scanners in a collective packaging box Dimensions 650 mm W x 550 mm D x 250 mm H Note The RO mark labeled on the package tray or package box guarantees that the applicable product has passed our test of RoHS restrictions compliance the restriction of the use of certain hazardous substances...

Page 35: ...ance 90 mm Angle α 0 β 15 γ 0 Curvature R Power Supply Voltage 5 0 V 13 2 Shock 13 2 1 Drop Test without packaging No malfunction occurred after the following drop test Drop Test Drop the scanner from a height of 150 cm onto a concrete floor three times on each of 5 sides Figure 26 Drop test 13 2 2 Drop Test with individual packaging No malfunction occurred after the following drop test Drop Test ...

Page 36: ...ement environment Use electrostatic testing device compliant with IEC 61000 4 2 Discharge resistance 330 Ω Capacitor charging 150 pF 13 5 Dust and Drip Proof IEC IP42 13 6 Cable Strength 13 6 1 Cable Pulling Test No malfunction occurred after the following pulling test Pulling test Fix the scanner and pull the cable with the force of 2 5 kg 24 5N for 1 second Repeat 20 times 13 6 2 Cable Tail Bend...

Page 37: ...r detecting reflection from the surface when the auto trigger is used Auto trigger distance 50 10 mm from the edge of the scanner Conditions Moving Speed 100 10 mm s the moving direction is not specified Angle Skew angle excluding Pitch Angle and Dead Zone specified in section 7 3 Pitch Skew and Tilt Environmental Temperature and Humidity Room temperature and humidity Environmental Illuminance 500...

Page 38: ...r mode Descriptions in show menu IDs Figure 29 Trigger options 15 1 Auto Trigger Settings 15 1 1 Stand Only Enable auto trigger only when the scanner is inserted into the stand Functions Menu labels Menu codes SET _ZZ_ ZZ Enable auto trigger _ I_ I Enable auto trigger stand detection _ 4_ 4 END _ZZ_ ZZ If the scanner is removed from the stand auto trigger is disabled and the scanner should be trig...

Page 39: ...to trigger stand detection _ 5_ 5 END _ZZ_ ZZ 15 1 3 Manually Only trigger manually default Functions Menu labels Menu codes SET _ZZ_ ZZ Disable auto trigger _ F_ F Disable auto trigger stand detection _ 4_ 5 END _ZZ_ ZZ A magnetic switch and a magnet are used for stand detection operation Therefore auto trigger may be activated when there is a magnetic substance nearby ...

Page 40: ...t VCCI If this is used near a radio or television receiver in a domestic environment it may cause radio interference Please install and use the equipment according to the instruction manual FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must acce...

Page 41: ...Do not throw the scanner into the fire Do not forcibly bend the cables at low temperatures 17 3 Foreign Materials Do not immerse the scanner in liquids Do not subject the scanner to chemicals 17 4 Other Do not plug unplug the connectors before disconnecting the power Do not disassemble this product Do not use the scanner near a radio or a TV receiver It may cause reception problems The scanner may...

Page 42: ...Opticon OPR 2001 Specifications Manual 42 18 Mechanical Drawing Dimensions 151 0 mm x 56 0 mm x 30 5 mm except protruding parts Figure 30 Mechanical drawing ...

Reviews: