9.  Cable and Connector 

9.1.  RS-232C Cable  

(Standard specification) 

 

Figure 18: RS-232C cable 

 

Type:  

Straight cable 

Diameter: 

φ

3.8±0.5 mm 

Length: 

1500±50 mm  

Cores: 

6 insulated wires, 1 conductive wire 

Weight: Approximately 

40 

 

9.2.  USB Cable  

(Standard specification) 

 

Figure 19: USB cable 

Summary of Contents for OPL 7836

Page 1: ...Handheld Laser Barcode Scanner OPL 7836 The OPL 7836 is a handheld laser barcode scanner Specifications Manual ...

Page 2: ...ts that are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or incidental da...

Page 3: ...ations 9 6 1 Laser Scan Specifications 9 6 1 1 Tilt of Laser Scan Line 9 6 1 2 Curvature of Scan 10 7 Technical Specifications 10 7 1 Print Contrast Signal PCS 10 7 2 Minimum Resolution 10 7 3 Scan Area and Resolution 11 7 3 1 Depth of Field 11 7 4 Pitch Skew and Tilt 12 7 4 1 Pitch Angle 12 7 4 2 Skew Angle and Dead Zone 13 7 4 3 Tilt Angle 14 7 5 Curvature 15 8 Interface Specifications 16 8 1 RS...

Page 4: ... 1 Set Default Interface 28 10 2 Default Settings 1 Readable Codes 29 10 3 Default Settings 2 Read Options Trigger Buzzer 31 11 Serial Number and Labeling 32 12 Packaging Specifications 32 12 1 Individual Packaging Specification 32 12 2 Collective Packaging Specification 32 13 Durability 33 13 1 Electrical Noise 33 13 2 Static Electricity 33 13 3 Shock 34 13 3 1 Drop Test without packaging 34 13 3...

Page 5: ...scan tilt and curvature 10 Figure 2 The depth of a decoding field measured from the edge of the scanner 11 Figure 3 Pitch angle 12 Figure 4 Skew angle and dead zone 13 Figure 5 Tilt angle 14 Figure 6 Curvature 15 Figure 7 Interface circuit 17 Figure 8 Character format same for both sending and receiving 17 Figure 9 Communication format 17 Figure 10 No handshaking 18 Figure 11 Busy Ready communicat...

Page 6: ...s Manual 6 Figure 21 WEDGE cable 26 Figure 22 Front view 26 Figure 23 Front view 27 Figure 24 Serial number diagram 32 Figure 25 Caution label 32 Figure 26 Drop test 34 Figure 27 Cable bending test 35 Figure 28 Mechanical drawing 40 ...

Page 7: ...upported symbologies Linear 1D Postal 2D JAN UPC EAN incl add on Chinese Post Composite codes Codabar NW 7 Korean Postal Authority Code MicroPDF417 Code 11 PDF417 Code 39 Code 93 Code 128 GS1 128 EAN 128 GS1 Databar RSS IATA Industrial 2of5 Interleaved 2of5 ISBN ISMN ISSN Matrix 2of5 MSI Plessey S Code Telepen Tri Optic UK Plessey The OPL 7836 outputs the scanned barcode image via an RS 232C USB o...

Page 8: ...the range of illumination on a barcode surface is between zero and the following values Incandescent light to 3 000 lx Fluorescent light to 3 000 lx Sunlight to 50 000 lx Conditions Barcode Sample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Distance 85 mm Angle α 0 β 15 γ 0 Curvature R Power Supply Voltage 5 0 V Direct light or ...

Page 9: ...ost computer to which the device is connected 6 Optical Specifications 6 1 Laser Scan Specifications Parameter Specification Unit Light emitting element Red laser diode Emission wavelength 650 10 25 C nm Light output 1 0 or less mW Scanning method Bi directional scanning Scanning speed 100 20 scans s Scan angle 54 5 Scan angle Read angle 44 Min Notes Refer to chapter 15 Trigger and Read Options to...

Page 10: ...h section Conditions Ambient temperature and humidity Room temperature 5 to 35º C Room humidity 45 to 85 RH Ambient light 500 to 900 lx Background Barcode black Space white Margin white Background of label black Power supply voltage 5 0 V Decoding test Approve the performance when decoding is successful in all ten tests Decoding is deemed successful when completed in 0 5 seconds or less 7 1 Print ...

Page 11: ...ection Depth of field Y direction Laser scan widths within the depth of field Figure 2 The depth of a decoding field measured from the edge of the scanner Symbology Resolution Depth of field mm PCS Code 39 1 0 mm 50 500 0 9 Code 39 0 5 mm 30 300 0 9 Code 39 0 25 mm 30 240 0 9 Code 39 0 15 mm 30 130 0 9 Code 39 0 127 mm 40 100 0 9 Conditions Barcode Sample OPTOELECTRONICS Test Sample N W ratio 1 2 ...

Page 12: ...ution Symbology PCS Quiet Zone Digit 1 0 mm Code 39 0 9 25 mm 1 0 5 mm Code 39 0 9 18 mm 3 0 25 mm Code 39 0 9 10 mm 8 0 15 mm Code 39 0 9 7 mm 10 0 127 Code 39 0 9 5 mm 4 7 4 Pitch Skew and Tilt 7 4 1 Pitch Angle α 35 α 35 α 35 Figure 3 Pitch angle ...

Page 13: ...icon OPL 7836 Specifications Manual 13 7 4 2 Skew Angle and Dead Zone β 50 Excluding dead zone β 8 There are some areas in which decoding fails due to specular reflection Figure 4 Skew angle and dead zone ...

Page 14: ... the front edge of the scanner Label Pitch Skew Angle Dead Zone PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 N W Ratio 1 2 5 Tilt Angle PCS 0 9 Resolution 0 26 mm Symbology 13 digit JAN Quiet Zone 10 mm Angle At Pitch Skew angle β 15 Tilt angle 0 At Tilt angle Pitch angle α 0 Skew angle β 15 At Skew angle and dead zone Pitch angle α 0 Tilt angle γ 0 Curvature R ...

Page 15: ...rformance is guaranteed when R 15 mm With 13 digit JAN UPC EAN barcodes decoding performance is guaranteed when R 20 mm Figure 6 Curvature Conditions Barcode Sample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 26 mm Quiet Zone 10 mm Distance 90 mm from the edge of the scanner Angle Skew Angle β 15 ...

Page 16: ...ng time Infinite You can change the communication condition using the menu barcode 8 1 2 Signal Level Signal Name I O RS 232C Level V Mark OFF Space ON TxD OUT 5 to 15 5 to 15 RxD IN 3 to 15 3 to 15 RTS OUT 5 to 15 5 to 15 CTS IN 3 to 15 3 to 15 8 1 3 Pin Assignment Signals Pin No Remarks NC 1 No connection TXD 2 RXD 3 4 6 pin and jumper GND 5 6 4 pin and jumper CTS 7 RTS 8 NC 9 No connection F GN...

Page 17: ...e 7 Interface circuit 8 1 5 Character Format Figure 8 Character format same for both sending and receiving 8 1 6 Communication Format Figure 9 Communication format TXD RXD RTS CTS VCC GND F GND ホスト 本機 ADM3202相当品 DC INPUT ADM3202 Compatibility Product Scanner Host Computer ...

Page 18: ...ndshaking options using the menu or command listed below Handshaking Menu Command No handshake P0 BUSY READY P1 MODEM P2 ACK NAK P3 ACK NAK NO RESPONSE P4 a No Handshaking The scanner attempts the communication regardless of the state of the host computer Figure 10 No handshaking ...

Page 19: ...n parts of the process such as receiving data buzzer command execution transmitting data and menu processing The scanner checks the CTS line before transmitting data When it is ON the scanner transmits data When it is OFF the scanner waits for it to turn ON within a set time The scanner will abort transmission with an error indication buzzer when the CTS line is not ON within a specified period Th...

Page 20: ... and waits When the CTS signal is turned ON while transmitting a character the character will be transmitted Figure 13 Signal timing Note When using loopback wire connection for RTS CTS line of the scanner in this setting No handshake is not enabled c MODEM The scanner turns CS line ON before transmitting data Other processes are the same as BUSY READY Figure 14 Modem transmit data ...

Page 21: ...l state NAC response Action The scanner sends the data again and waits for the response from the host DC1 response Action The scanner returns to waiting for the trigger if it has a trigger the initial state None response Action The scanner sounds the error buzzer and returns to the initial state ACK NAK timeout can be set as follows using the menu or commands ACK NAK timeout Menu Command Indefinit...

Page 22: ... NAK NO RESPONSE When no response from the host is received within the setting time the scanner assumes an ACK response and returns to the initial state without the error buzzer The other actions are the same as ACK NAK Figure 16 ACK NAK No response ...

Page 23: ...during data transmission from the scanner to host It may cause problems with the data transmission 8 3 DOS V Wedge Interface 8 3 1 Settings a Desktop type used in combination with external keyboard Set by default this procedure is only used when settings are changed Scan menu bar code ZZ UB KM ZZ to set the DOS V Wedge interface for desktop type b Notebook type without external keyboard Scan menu ...

Page 24: ...onnector 9 1 RS 232C Cable Standard specification Figure 18 RS 232C cable Type Straight cable Diameter φ3 8 0 5 mm Length 1500 50 mm Cores 6 insulated wires 1 conductive wire Weight Approximately 40 g 9 2 USB Cable Standard specification Figure 19 USB cable ...

Page 25: ...Straight cable Diameter φ3 8 0 5 mm Length 1500 100 mm Cores 4 insulated wires 1 conductive wire Weight Approximately 40 g 9 2 1 Connector USB interface a USB A connector Figure 20 USB A connector Contact Number Signal Name 1 VCC 2 DATA 3 DATA 4 GND ...

Page 26: ...ification Figure 21 WEDGE cable Type Y cable Diameter φ3 8 0 5 mm Length 1500 100 mm Cores 6 insulated wires 1 conductive wire Weight Approximately 50 g 9 3 1 Connector Wedge interface a DOS V HOST Side Figure 22 Front view Contact Number Signal Name 1 CPU_DATA 2 KEY_DATA ...

Page 27: ..._DATA 2 OPEN 3 GND 4 VCC 5 KEY_CLK 6 OPEN Do not use the keyboard of host during data transmission from the scanner to host It may cause problems with the data transmission 9 4 Connector Specification for scanner CN 1 10 pin Pin No RS 232C USB WEDGE 1 RTS 2 CTS 3 TXD 4 RXD 5 5V 5V 5V 6 GND GND GND 7 DATA KEY_CLK 8 DATA KEY_DATA 9 CPU_CLK 10 CPU_DATA ...

Page 28: ...urn to the default settings RS 232C Functions Menu labels Menu codes SET _ZZ_ ZZ RS 232C _U2_ U2 END _ZZ_ ZZ USB HID Functions Menu labels Menu codes SET _ZZ_ ZZ USB HID _SU_ SU END _ZZ_ ZZ Wedge with external keyboard Functions Menu labels Menu codes SET _ZZ_ ZZ AT Wedge _UB_ UB Keyboard layout with keyboard _KM_ KM END _ZZ_ ZZ ...

Page 29: ...mit CD Calculate CD Set Prefix Set Suffix Other UPC A X CR UPC A Add on X X CR UPC E X CR UPC E Add on X X CR EAN 13 X CR EAN 13 Add on X X CR EAN 8 X CR EAN 8 Add on X X CR Chinese Post Matrix 2of5 X X X CR Codabar NW 7 X X CR Not transmit ST SP Code 11 X X X CR Code 39 X X CR Not transmit ST SP Code 93 X X CR Code 128 X X CR GS1 128 EAN UCC 128 X X X CR GS1 DataBar RSS all incl CC A B Limited Ex...

Page 30: ...CR Not transmit ST SP UK Plessey X CR Notes In the Reading column means Enable reading and X means Disable reading In the Transmit code length column means Transmit code length and X means Do not transmit code length In the Transmit CD column means Transmit check digit and X means Do not transmit check digit In the Calculate CD column means Calculate check digit and X means Do not calculate check ...

Page 31: ...ad reset time 500 ms Add on wait mode 500 ms Redundancy Read 4 times redundancy 3 Trigger switch Enable Trigger repeat Disable Auto trigger Disable refer to the Universal Menu Book for details Read time 2 seconds Margin check Normal Buzzer duration 50 ms Buzzer tone Single tone 3 kHz Buzzer loudness T1 Loud Buzzer transmission Before transmission Startup buzzer Enable Good read LED Indicator durat...

Page 32: ... a protective foam bag and place it in an individual packing box Size of the package after assembly W 245 x D 110 x H 85 mm 12 2 Collective Packaging Specification Place 50 individual boxes with scanners inside a box Note The RO mark labeled on the package tray or package box guarantees that the applicable product has passed our test of RoHS restrictions compliance the restriction of the use of ce...

Page 33: ...ample OPTOELECTRONICS Test Sample PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Distance 90 mm Angle α 0 β 15 γ 0 Curvature R Power Supply Voltage 5 0 V 13 2 Static Electricity Air discharge 10kV Max No malfunction 15kV Max No destruction Measurement environment Use electrostatic testing device compliant with IEC 61000 4 2 Discharge resistance 330Ω Capacitor...

Page 34: ...ation 13 4 1 Vibration Strength without packaging There was no sign of malfunction with the scanner s exterior appearance or its operation after the following vibration test In the non operating state increased the frequency of the vibration from 10 Hz to 100 Hz with accelerated velocity 2 0 G 19 6 m s2 for over 30 minutes 60 minutes for one cycle Repeated this routine for X Y and Z direction resp...

Page 35: ...he following static load test With the scanner fixed pulled the cable with static load 24 5 N or 2 5 kgf for a second Repeated this routine 20 times 13 7 Cable Bending Test There was no sign of malfunction with the scanner s structure and its performance after the following flexing test Applied load 4 9N or 500gf to the cable and flex it 60 degrees to the left and right as shown below Repeated thi...

Page 36: ...ws 15 1 Auto Trigger Options 15 1 1 Auto Trigger Sensor The product has an optional auto trigger setting which starts barcode reading automatically by using sensor detection The scanner starts barcode reading after detecting reflection from the surface when the auto trigger is used Auto trigger distance 50 10 mm from the edge of the scanner Conditions Moving speed 100 10 mm s Angle Vertical to the...

Page 37: ...ble the auto trigger Auto trigger is disabled by default To enable auto trigger scan ZZ I and ZZ in that order To disable auto trigger scan ZZ F and ZZ in that order Functions Menu labels Menu codes SET _ZZ_ ZZ Disable auto trigger _ F_ F Enable auto trigger _ I_ I END _ZZ_ ZZ Note Please configure the following after enabling the auto trigger ...

Page 38: ...be used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment VCCI If this is used near a radio or television receiver in a domestic environment it may cause radio interference Please install and use the equipment according to the instruction manual FCC Part 15 Subpart B Class B This device complies with...

Page 39: ...throw the scanner into the fire Do not forcibly bend the cables at low temperatures 17 3 Foreign Materials Do not immerse the scanner in liquids Do not subject the scanner to chemicals 17 4 Other Do not plug unplug the connectors before disconnecting the power Do not disassemble this product Do not place the product near a radio or a TV receiver as the scanner may cause reception problems The scan...

Page 40: ...Opticon OPL 7836 Specifications Manual 40 18 Mechanical Drawing Dimensions 144 5 x 113 0 x 54 3 excluding cable connection Figure 28 Mechanical drawing ...