Exercise caution at all times when
working with AC-powered equipment.
Turn off your devices before
installation.
Because of the special pin-out of the
connectors, use the cables supplied
by the manufacturer.
When you need another cable for a
certain device, that is not supplied,
contact your supplier to purchase the
right cable. In case another cable is
used, take notice of the pin-out
specifications further in this manual.
2.6.1 Single cradle
2.6.2 Cradle network
!
!
!
!
Connection sequence
for single cradle:
Place the cradle in normal office conditions,
avoid a place under strong light.
Disconnect the power supply.
Set the required DIPswitches for
baud rate and function.
Connect the interface cables.
Connect the power supply.
Place the PHL1300 terminal in the cradle.
Connection sequence
for cradle network:
Set all cradles to the same baud rate (by
DIPswitch)
Only 1 cradle in the network will be
connected to the PC through one RS232
cable. On this cradle the DIPswitch for
RS232 connection must be enabled.
Through this connection all cradles can
communicate to the PC.
A maximum of 16 cradles can be
connected in a network through RS485
cables. For the cradles that are not
directly connected to the PC the
DIPswitch for RS232 connection must
be set to off.
The first and the last cradle in the network
must have the termination resistors set by
dipswitch.
2.6 INSTALLING IN A SYSTEM
DB9
CRADLE
RS 232
DB25 / DB9
HOST
RS 485
sw 1 = off
sw 2 = off
sw 3 = off
RS 232
TRANSMISSION
HOST
TERMINATED RS 485
sw 1 = on
sw 2 = on
sw 3 = on
RS 485 TERMINATED
sw 1 = off
sw 2 = on
sw 3 = on
//