Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS: 0.9
Resolution: 0.25
mm
Symbology:
9-digit Code 39
Quiet Zone:
10 mm
N/W Ratio:
1:2.5
Distance: 70
mm
Angle:
α
= 0°
β
= 15°
γ
= 0°
Curvature:
R
=
∞
Power Supply Voltage:
5.0 V
Direct light or specular reflection light from a source should be prevented from entering
the acceptance area.
Note:
α
,
β
and
γ
respectively represent pitch, skew and tilt. Please see section 7 for how
these values are defined.
5. Electrical
Specifications
5.1. Framework and Structure
This product consists of an optical section, a decode and a communication section. The
optical section includes a CCD for decoding and an illumination LED. The decode section
decodes scanned data and carry out signal processing. The communication interface
section converts 3.3V power supply and outputs decoded data and signals to the buzzer,
LEDs and trigger key
The C37 with RS-232C interface requires the supplied AC adaptor.
The C37 with Wedge or USB interface uses bus power. It does not require an AC
adaptor.
Figure 2: Framework and structure diagram
D
ECODE
&
C
OMMUNICATION
C
ONTROL
S
ECTION
ASIC + ROM / RAM
O
PTICAL
S
ECTION
CCD
I
LLUMI
-
NATIO
N
LED
AC
A
DAPTER
H
OST
+6.0V
+5.0V
P
OWER
S
UPPLY
3.3V
Å
+4.5
~
6.6V
I
NTERFACE
(RS-232C
/
USB
/
W
EDGE
)
T
RIGGER
K
EY
LED
B
UZZER
H
OST