Opticon C 37 Specification Manual Download Page 21

Opticon 

C37 

Specifications Manual 

 
 
 
 

 

21 

8.2.  USB-HID and USB-VCP Interface Specifications 

8.2.1. 

Settings 

Reading the menu barcodes in section 10.1 can set the USB interface default. 
The interface is full-speed USB (12 Mbps). 

Note:

 You must install the USB-VCP driver on the host. 

8.2.2. 

Interface Circuit 

 

Figure 15: Interface circuit 

Do not use the keyboard while the scanner is transmitting the data to the host. 
Doing so may cause failure in data transactions. 

8.3.  DOS/V Wedge Interface Specification 

Reading the menu barcodes in section 10.1 can set the DOS/V Wedge interface default. 

For either interface (USB or HID/Wedge)—Set the language for the scanner and PC 
keyboard to the same language before use; otherwise, the output may not be correct. 

Summary of Contents for C 37

Page 1: ...CCD Barcode Scanner C37 The C37 is a handheld linear image scanner Specifications Manual...

Page 2: ...are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges...

Page 3: ...teristics 10 5 2 1 RS232 10 5 2 2 USB Wedge 10 5 3 AC Adaptor Specifications 10 5 3 1 Input Specifications 10 5 3 2 Output Specifications 11 6 Optical Specifications 11 6 1 CCD Specifications 11 7 Tec...

Page 4: ...2 USB Cable 22 9 2 1 Connector 22 9 2 2 Pin Assignment 23 9 3 Wedge Cable 23 9 3 1 Connectors 24 9 4 Connector Specification Scanner Side 25 10 Default Settings 25 10 1 Set Default Interface 25 10 2...

Page 5: ...r 35 19 Mechanical Drawing 36 Table of Figures Figure 1 Ambient light immunity 8 Figure 2 Framework and structure diagram 9 Figure 3 Depth of field 13 Figure 4 Pitch 13 Figure 5 Skew angle and dead zo...

Page 6: ...20 DOS V host connector 24 Figure 21 DOS V keyboard connector 24 Figure 22 Serial number diagram 29 Figure 23 Drop test 31 Figure 24 Cable tail bending test 32 Figure 27 Mechanical drawing Scanner 36...

Page 7: ...gative barcodes Scanned data is transferred via an RS 232C USB or Wedge interface Auto trigger settings are available The C37 complies with RoHS Supported symbologies Linear 1D Postal JAN UPC EAN incl...

Page 8: ...g Temperature and Humidity Temperature 0 to 50 C Humidity 5 to 95 RH 4 2 Storage Temperature and Humidity Temperature 20 to 60 C Humidity 5 to 95 RH 4 3 Ambient Light Immunity Decoding performance is...

Page 9: ...ists of an optical section a decode and a communication section The optical section includes a CCD for decoding and an illumination LED The decode section decodes scanned data and carry out signal pro...

Page 10: ...uto trigger ON IPRE 60 70 mA 5 2 2 USB Wedge Parameter Symbol Min Typ Max Unit Operating voltage VOP 4 5 5 0 5 5 V Operating current 1 LED ON Buzzer OFF IOP 95 110 mA Operating current 2 LED ON Buzzer...

Page 11: ...ly voltage is measured at a connector terminal area The current value depends on the interface type and host computer to which the device is connected 6 Optical Specifications 6 1 CCD Specifications P...

Page 12: ...erformance when decoding is successful in all ten tests Decoding is deemed successful when completed in 0 5 seconds or less 7 1 Print Contrast Signal PCS 0 45 or higher over 70 of reflectivity of spac...

Page 13: ...ield 0 to15 mm The depth of field is measured from the edge of the scanner Figure 3 Depth of field Conditions Barcode Sample OPTOELECTRONICS Test Sample N W Ratio 1 2 5 Angle 0 0 0 Curvature R 7 4 Pit...

Page 14: ...eas in which decoding fails due to specular reflection 1 2 0 Figure 5 Skew angle and dead zone 7 4 3 Tilt Angle Scanning performance is guaranteed when 25 Figure 6 Tilt angle Conditions Barcode Sample...

Page 15: ...e OPTOELECTRONICS Test Sample Angle Pitch angle 0 Skew angle 0 Tilt angle 0 8 Interface Specifications 8 1 RS 232C Interface 8 1 1 Settings and Communication Reading the menu barcodes in section 10 1...

Page 16: ...o 15 3 to 15 RTS OUT 5 to 15 5 to 15 CTS IN 3 to 15 3 to 15 8 1 3 Pin Assignment Signal Pin Notes NC 1 Open not connected TXD 2 RXD 3 4 Connected to pin 6 with jumper cable GND 5 6 Connected to pin 4...

Page 17: ...terface Circuit Figure 8 Interface circuit 8 1 5 Character Format Uses the same format for both sending and receiving Figure 9 Character format same for both sending and receiving 8 1 6 Communication...

Page 18: ...tion regardless of the state of the host computer Figure 12 No handshaking c ACK NAK After data has been transmitted the scanner expects to receive one of the following responses from the host ACK res...

Page 19: ...con C37 Specifications Manual 19 ACK NAK timeout can be set as follows using the menu or commands ACK NAK timeout Menu Command Indefinitely default XI4 100 ms XI5 500 ms XI6 1000 ms XI7 Figure 13 ACK...

Page 20: ...NO RESPONSE When no response from the host is received within the setting time the scanner assumes an ACK response and returns to the initial state without the error buzzer The other actions are the...

Page 21: ...ost 8 2 2 Interface Circuit Figure 15 Interface circuit Do not use the keyboard while the scanner is transmitting the data to the host Doing so may cause failure in data transactions 8 3 DOS V Wedge I...

Page 22: ...500 50 0 mm Cores 6 insulated wires 1 conductive wire Weight Approximately 65 g Figure 16 RS 232C cable 9 2 USB Cable Standard specification Type Straight Diameter 4 8 0 5 mm Length 1500 50 0 mm Cores...

Page 23: ...ndard specification Type Y cable Diameter 4 8 0 5 mm Length 1500 50 0 mm Cores 6 insulated wires 1 conductive wire Weight Approximately 40 g Wedge Y adapter specification Type Straight Diameter 4 8 mm...

Page 24: ...mber Signal Name 1 CPU_DATA 2 NC 3 GND 4 VCC 5 CPU_CLK 6 NC b DOS V Keyboard Connector 4 6 3 5 1 2 Figure 21 DOS V keyboard connector Contact Number Signal Name 1 KEY_DATA 2 NC 3 GND 4 VCC 5 KEY_CLK 6...

Page 25: ...K 8 NC DATA KEY_DATA 9 NC CPU_CLK 10 NC CPU_DATA 11 VCC VCC VCC 12 FG shield FG shield FG shield 10 Default Settings 10 1 Set Default Interface Scan the following menu barcodes to return to the defaul...

Page 26: ...01 END _ZZ_ ZZ Wedge with external keyboard Functions Menu labels Menu codes SET _ZZ_ ZZ AT Wedge _UB_ UB Keyboard layout with keyboard _KM_ KM END _ZZ_ ZZ Wedge without external keyboard Functions Me...

Page 27: ...ost Matrix 2of5 X X X CR Codabar NW 7 X X CR Not transmit ST SP Code 11 X X X CR Code 39 X X CR Not transmit ST SP Code 93 X X CR Code 128 X CR GS1 128 EAN UCC 128 X X CR GS1 DataBar RSS incl CC A B O...

Page 28: ...all codes Read mode Single read Multiple read reset time 500 ms Add on wait mode 500 ms Multiple column read Disable Default option X0 setting Read 2 times redundancy 1 Redundancy Other options X1 X3...

Page 29: ...single packing box Size of the package after assembly 245 W x 110 D x 40 H mm 12 2 Collective Packaging Put 50 individually packaged C37 scanners in a collective packaging box Dimensions 650 mm W x 5...

Page 30: ...13 2 Static Electricity Air discharge No malfunction 10 kV max Air discharge No destruction 15 kV max Direct discharge No malfunction 10 kV max Direct discharge No destruction 15 kV max Contact disch...

Page 31: ...curred after the following drop test Drop Test Drop the scanner from a height of 150 cm onto a concrete floor on each of one corner three edges and six sides 10 drop tests in total 13 4 Vibration Stre...

Page 32: ...nction occurred after the following bending test Bending test Fix the scanner and attach a weight of 500 grams 4 9N swing the cable back and forth at an angle of 90 Repeat it 1 000 000 times Figure 24...

Page 33: ...auto trigger is used 16 Trigger and Read Settings 16 1 1 Enable Disable Settings Use the following settings to enable or disable the auto trigger Auto trigger is disabled by default To enable auto tri...

Page 34: ...is used near a radio or television receiver in a domestic environment it may cause radio interference Please install and use the equipment according to the instruction manual FCC Part 15 Subpart B Cl...

Page 35: ...o not immerse the scanner in liquids Do not use in dusty environments Do not subject the scanner to chemicals Do not insert foreign substances into the device 18 4 Other Do not plug unplug the connect...

Page 36: ...Opticon C37 Specifications Manual 36 19 Mechanical Drawing Dimensions 149 5 mm x 74 5 mm x 52 5 mm except protruding parts Figure 25 Mechanical drawing Scanner...

Page 37: ...Opticon C37 Specifications Manual 37 AC INPUT Dimensions 47 5 W 28 0 D 75 0 H mm except protruding parts Cable Length 1 8 m DC OUTPUT Figure 26 Mechanical drawing AC adapter...