Product Specifications
M1-1P0x Optical DVI Extension Cable
Compliance with DVI standard:
support DVI1.0 and DDC2B, fully
implemented by fiber-optic communication.
Extension limit:
100m (330feet) for UXGA (1600x1200) at 60 Hz
refresh rate.
Graphic Transmission Bandwidth:
support UXGA at 60Hz, or
1.65Gbps bandwidth per graphic channel.
Hybrid Fiber-optic (H-PCF) Cable:
Riser Jacket of retardant PVC
employing 4 strands H-PCF (Hard Polymer Cladding Fiber) having
200/225
µ
m core/clad.
Tensile load: 1,800N
Minimum bend radius: 25mm
Outer diameter of cable: 7.2mm
Mechanical specifications of Tx and Rx modules
Dimensions:
29mm / 15mm / 53mm (W/H/D)
Clamping strength to cable
: 14kg
f
Environmental Specifications
Operating temperature: 0°C to 50°C
Storage temperature: - 40°C to 70°C
Humidity: 5% to 85%
AC/DC Power Adapter
Power Input:
AC 100-240V, 50/60Hz 0.1A
Power Output:
+5 V, 600 mA SMPS DC-power Adapter
Cord DC Jack:
Core is 5 V and outer is GND.
1-6 Product Specifications
Troubleshooting
The display displays only black screen.
Ensure that all AC and DC plugs and jacks used by external power supplies
(both Opticis and others) are firmly connected. Ensure that power bars are
live.
Ensure that the DVI ports are firmly plugged in to the PC and display. Ensure
that the Tx and Rx modules plug correctly to the PC and display, respectively.
Check if the PC and display are powered on and properly booted.
Reset the system by de-plugging and re-plugging the Tx DVI port or Rx DVI
port, or by de-plugging and re-plugging the power cord plugs of Tx and Rx
modules.
Re-boot up the system while connecting the optical DVI cable system.
Screen is distorted or displays noises.
Check if the graphic resolution is properly set. Go to the display properties of
Windows and tap the settings. Ensure that the resolution sets less than
UXGA (1600x1200) at 60Hz refresh ratio.
Reset the system. Disconnect and reconnect the optical DVI cables or DC
power adapters.
Maintenance
No special maintenance is required for the optical DVI cables and power
supplies. Ensure that the cables and power modules are stored or used in a
benign environment free from liquid or dirt contamination.
There are no user serviceable parts. Refer all service and repair issues to
Opticis.
Technical Support and Service
For commercial or general product support, contact your reseller. For
technical service, contact Opticis by email
or visit its
website at www.opticis.com
1-5 Troubleshooting, Maintenance, Technical Support