32
Chapter 6. Command input operation
The OMM-2500 modular matrix could be operated with various interfaces such as Touch LCD, key
button inputs, command input through RS-232 and TCP/IP, Web control through TCP/IP and PC
program through RS-232 and UDP. All functions are executed on a basis of a serial command input,
but the graphic interfaces on the Web or the PC program make more efficient way to operate the
OMM-2500 modular matrix.
Command input operation is accomplished through RS-232 or TCP/IP.
For setting procedures for those protocols, please refer to Chap 2 and Chap 3.
6.1 Command input structure
The command inputs are composed of a string of ASCII codes and its basic structure is;
C Delimiter (
‘=’) + Data + Delimiter (‘^’ or ‘,’ or ‘_’) + Data + End (‘!’)
Table 6.1 shows all commands and its brief descriptions
Command
Description
LINK
Input and Output connection
IN
Input signal status request
OUT
Output signal status request
INNAME
Input Channel Name Request and setting
OUTNAME
Output Channel Name Request and setting
NET
Network information request
NETGW
Gateway address setting
NETSN
Subnet mask address setting
NETIP
IP address setting
NETPA
MAC address setting
NETPT
UDP port number setting
VID
Video generator status request
VIDRES
Video generator resolution setting
VIDIMG
Video generator pattern setting
MON
Monitoring port setting and status request
EDID
EDID mode setting
HDCP
HDCP On/Off request and setting
RS232
RS-232 Baud rate request setting
QUAD
Quad-viewer card status request
QUADRES
Quad-viewer card output resolution setting
QUADLAY
Quad-viewer card layout setting
PRE
Preset Load and save
PRENAME
Preset name request and Setting
SLOT
Input output slot status request
LOCK
Lock/Unlock the control type
PWR
SMPS Power On/Off State Request
VER
MAIN In Out Firmware Version Request
Table 6.1 Commands set