Optical Systems OSD2151 SERIES Operator'S Manual Download Page 1

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

OPERATOR MANUAL 

 
 
 
 
 

OSD2151 SERIES 

GIGABIT ETHERNET 

MEDIA CONVERTER 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for OSD2151 SERIES

Page 1: ...OPERATOR MANUAL OSD2151 SERIES GIGABIT ETHERNET MEDIA CONVERTER...

Page 2: ......

Page 3: ...2 1 WARNING AND PRECAUTIONS 9 2 2 2 OSD2151 DRAWINGS AND DIMENSIONS 10 2 2 3 POWER SUPPLY CONNECTIONS 10 2 2 4 FIXED RJ45 COPPER PORT PIN ASSIGNMENTS 11 2 2 5 LED INDICATORS 11 2 2 6 CONTROLS 12 2 2 7...

Page 4: ...S 11 FIGURE 7 OSD2151 3 WAY DIP SWITCH 12 FIGURE 8 FITTING REMOVING SFP CONNECTORS 13 FIGURE 9 BASIC CONNECTIONS 13 FIGURE 10 LINK LOSS FORWARDING FUNCTION 14 FIGURE 11 SINGLE UNIT CONFIGURATION 14 FI...

Page 5: ...operation over the 20 C to 65 C temperature range which allows it to be used in environments such as roadside cabinets mine sites and factories 1 1 2 APPLICATIONS Any network utilising a mix of coppe...

Page 6: ...110603 OSD2151 OPERATOR MANUAL PAGE 6 1 2 TYPICAL CONFIGURATION Figure 1 below indicates the typical set up for an OSD2151 system FIGURE 1 OSD2151 TYPICAL CONFIGURATIONS PC Network Switch 1000Base T E...

Page 7: ...duplex for 1000 Pause frames for 1000Mbps flow control Electrical Data Connector RJ45 Optical connector SFP SFP Options Short haul long haul single fiber operation etc Please consult OSD datasheet 10...

Page 8: ...sold separately giving the user choice to use either one or two fiber communications with various optical power outputs depending on the distance required The rear panel consists of a 2 way term bloc...

Page 9: ...t may cause radio interference in which case the user may be required to take adequate measures OPTICAL OUTPUT OPERATION WARNING Laser Safety Class 1 Laser Product per IEC EN 60825 1 20011 standard Cl...

Page 10: ...NNECTIONS The OSD2151 module requires external DC or AC power The voltage range of the OSD2151 is 8VDC to 35VDC or 20 to 28VAC 4VA Power should be connected to the power socket located at the back of...

Page 11: ...0Mbps Green 1Gbps No Copper Link Activity 1 Full Duplex on Copper Port Half Duplex on Copper Port Power On Power Off Fiber Link No Fiber Link Activity 1 Link Loss Forwarding Enabled Link Loss Forwardi...

Page 12: ...switch settings before powering the unit FIGURE 7 OSD2151 3 WAY DIP SWITCH TABLE 4 OSD2151 3 WAY DIP SWITCH SETTINGS SWITCH NUMBER DESCRIPTION SWITCH POSITION FUNCTION 1 Fault Detection OFF Detect LL...

Page 13: ...erting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP until it locks into place Remove plastic rubber dust cap and fit appropriate fib...

Page 14: ...it Configuration and Dual Unit configuration Figure 10 is a flow chart of the OSD2151 Link Loss Forwarding LLF function and operation FIGURE 10 LINK LOSS FORWARDING FUNCTION 2 3 1 SINGLE UNIT CONFIGUR...

Page 15: ...nse Action Disable Tx of copper port Disable Tx of copper port Restore Sequence 1 Fix fault and reconnect 2 Wait for link to be reestablished 1 Fix fault and reconnect 2 Wait for link to be reestablis...

Page 16: ...0Base X switch will thus be notified that there has been a copper link loss FIGURE 12 COPPER CONNECTION LOSS Figure 13 is an example of a fiber connection loss If the OSD2151 does not receive a valid...

Page 17: ...e damaged by failure of any portion of their support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performin...

Page 18: ...ve for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the...

Page 19: ......

Page 20: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Reviews: