background image

 

OPTICAL SYSTEMS DESIGN 

 

DOC ID: 10115804 

OSD2153P OPERATOR MANUAL

 

 

PAGE 19  

 

4

 

WARRANTY 

 

Thank you for purchasing equipment designed, manufactured and serviced by Optical Systems Design 
(OSD). OSD  warrants that at the time of  shipment, its products are free  from defects in  material and 
workmanship and conforms to specifications. Our Warranty conditions are outlined below: 

 
 
 

4.1

 

WARRANTY PERIOD 

 
For warranty period, please call your local OSD distributor. 
 

4.2

 

REPAIRS 

 
Optical  Systems  Design  reserves  the  right  to  repair  or  replace  faulty  modules/units.  Please  obtain  a 
“Return Material Authorisation” (RMA) form and number before returning goods. 
Goods  must  be  returned  in  adequate  packing  material  to  Optical  Systems  Design,  Warriewood  or  its 
nominated authorised representative, for all repairs. 
 
4.2.1

 

WARRANTY REPAIRS 

 
Return  shipments  to  OSD  shall  be  at  customer's  expense  and  freight  back  to  the  customer  will  be  at 
OSD expense. 
 
4.2.2

 

OUT-OF-WARRANTY REPAIRS 

 
OSD  reserves  the  right  to  repair  or  replace  any  faulty  goods.  Freight  costs  and  insurance  for  both 
journeys are met by the user. All equipment repaired by OSD will have a 3-Month Warranty from the 
date of dispatch.   
 
4.2.3

 

SITE REPAIRS 

 
By agreement site repairs may be undertaken for which out of pocket, hotel and travel expenses will be 
charged. 
 
4.2.4

 

EXCLUSIONS 

 
This  warranty  does  not  apply  to  defects  caused  by  unauthorized  modifications,  misuse,  abuse  or 
transport  damage  to  the  equipment.  All  modifications  to  OSD’s  standard  product  will  need  written 
authorization and will be charged at normal repair rates. All modifications are to be carried out by OSD 
Technicians.  Warranty  is  void  if  unauthorized  removal  and/or  tampering  with  serial  number  and/or 
repair labels is evident.  
 
 
 
 
 
 
 

Summary of Contents for OSD2153P

Page 1: ...OPERATOR MANUAL OSD2153P SERIES GIGABIT ETHERNET MEDIA CONVERTER WITH PoE ...

Page 2: ...OPTICAL SYSTEMS DESIGN DOC ID 10115804 OSD2153P OPERATOR MANUAL PAGE 2 ...

Page 3: ... 2 1 WARNING AND PRECAUTIONS 9 2 2 2 OSD2153P DRAWINGS AND DIMENSIONS 10 2 2 3 POWER SUPPLY CONNECTIONS 11 2 2 4 FIXED RJ45 COPPER PORT PIN ASSIGNMENTS 11 2 2 5 LED INDICATORS 12 2 2 6 CONTROLS 13 2 2 7 FITTING SFP CONNECTORS 14 2 2 8 BASIC CONNECTIONS 14 2 3 OSD2153P OPERATION 15 2 3 1 SINGLE UNIT CONFIGURATION 15 3 MAINTENANCE 18 3 1 INTRODUCTION 18 3 2 EXTERNAL INSPECTION 18 3 3 ROUTINE MAINTEN...

Page 4: ...GURE 7 LED INDICATORS 12 FIGURE 8 OSD2153P 3 WAY DIP SWITCH 13 FIGURE 9 FITTING REMOVING SFP CONNECTORS 14 FIGURE 10 BASIC CONNECTIONS 14 FIGURE 11 LINK LOSS FORWARDING FUNCTION 15 FIGURE 12 SINGLE UNIT CONFIGURATION 15 FIGURE 13 COPPER CONNECTION LOSS 17 FIGURE 14 FIBER CONNECTION LOSS 17 TABLE 1 TECHNICAL SPECIFICATIONS 7 TABLE 2 POWER CONNECTION 11 TABLE 3 LED FUNCTION 12 TABLE 4 OSD2153P 3 WAY...

Page 5: ...D2153P module is intended for isolated use and requires an external power source 1 1 2 APPLICATIONS Any network utilising a mix of copper and fiber Extremely space constrained environments Industrial IP communications Gigabit Ethernet networks 1 1 3 FEATURES AND BENEFITS Complies with IEEE802 3i 802 3u 802 3ab 10 100 1000Base T IEEE802 3z 1000Base Lx Sx standards Supports network traffic of 100Mbp...

Page 6: ...PTICAL SYSTEMS DESIGN DOC ID 10115804 OSD2153P OPERATOR MANUAL PAGE 6 1 2 TYPICAL CONFIGURATION Figure 1 below indicates the typical set up for an OSD2153P system FIGURE 1 OSD2153P TYPICAL CONFIGURATIONS ...

Page 7: ...J45 Controls 1 100 or 1000Mbps on fiber 2 Link Loss Forwarding On or off 3 Fault Detection fiber only or copper and fiber PoE IEEE802 3af IEEE802 3at and PoE Operating Mode Alternative A B Pins 1 2 3 6 4 5 and 7 8 Optical Port Connector SFP LC connectors for 2 fiber operation and SC for 1 fiber operation SFP Options Short haul long haul single fiber operation etc Please consult OSD datasheet 10210...

Page 8: ...he front panel The SFP device is sold separately giving the user choice to use either one or two fiber communications with various optical power outputs depending on the distance required On the rear panel is a 3 way DIP switch Each section will be described further throughout this manual OSD2153P Front Panel OSD2153P Rear Panel FIGURE 2 OSD2153P CONNECTORS Fixed RJ45 Copper Port SFP port Power In...

Page 9: ...uct may cause radio interference in which case the user may be required to take adequate measures OPTICAL OUTPUT OPERATION WARNING Laser Safety Class 1 Laser Product per IEC EN 60825 1 20011 standard Class 1 The OSD2153P is a Class 1 laser product PRECAUTIONS All service personnel should be provided training as to the hazards of direct viewing of laser radiation and of the precautionary measures d...

Page 10: ...d OSD2153P is designed to be mounted on an even surface and to be secured by means of M4 or smaller screws All dimensions are in mm The unit also can be mounted on a standard DIN rail with the OSD2153P DIN Rail bracket FIGURE 3 OSD2153P DIMENSIONS FIGURE 4 OSD2153P MOUNTING DIMENSIONS 27 5 79 1 20 2 4 2 Ø8 5 89 6 58 0 49 0 ...

Page 11: ...RE 5 MODULE POWER SUPPLY CONNECTIONS 2 2 4 FIXED RJ45 COPPER PORT PIN ASSIGNMENTS The OSD2153P complies with IEEE802 3af IEEE802 3at and PoE and is capable of supplying up to 60W of PoE The OSD2153P supports Mode A i e transmitting power over pins 1 2 3 6 and Mode B i e transmitting power over pins 4 5 7 8 For PoE the OSD2153P transmits power over all 8 pins Bidirectional data as well as power ter...

Page 12: ...D Copper Speed 10 100Mbps 1Gbps Yellow Green N A LNK ACT Copper Link Activity Amber No Copper Link Activity 1 PoE PoE Enable Green No PoE PWR Power On Green Power Off LLF Link Loss Forwarding Enabled Green Link Loss Forwarding Disabled LNK SPD Fiber Speed 100Mbps 3 Times Sec 1Gbps 6 Times Sec Green No Optical Link Activity 1 Note 1 Activity indicates traffic for both copper and fiber port ...

Page 13: ...ed switch settings before powering the unit FIGURE 8 OSD2153P 3 WAY DIP SWITCH TABLE 4 OSD2153P 3 WAY DIP SWITCH SETTINGS SWITCH NUMBER DESCRIPTION SWITCH POSITION FUNCTION 1 Optical Port Speed OFF 1000BASE X ON 100BASE X 2 Link Loss Forwarding OFF Disable ON Enable 3 Fault Detection OFF Detect LLF for copper and fiber loss ON Detect LLF for fiber loss only ON Position OFF Position 1 2 3 Fiber Spe...

Page 14: ...rting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP until it locks into place Remove plastic rubber dust cap and fit appropriate fiber cable Removing SFP Remove fiber connector Pull the SFP lever down to unlock SFP from housing Using the lever gently pull the SFP out Fiber SFP FIGURE 9 FITTING REMOVING SFP CONNECTORS 2 2 8 BASIC CO...

Page 15: ...nit Configuration and Dual Unit configuration Figure 11 is a flow chart of the OSD2153P Link Loss Forwarding LLF function and operation FIGURE 11 LINK LOSS FORWARDING FUNCTION 2 3 1 SINGLE UNIT CONFIGURATION The single unit configuration enables the user to connect the OSD2153P to any 1000Base X switch via the fiber port The fixed RJ45 copper port can be connected to a switch or PC using standard ...

Page 16: ...ponse Action Disable Tx of copper port Disable Tx of copper port Restore Sequence 1 Fix fault and reconnect 2 Wait for link to be reestablished 1 Fix fault and reconnect 2 Wait for link to be reestablished Copper link loss Response Action Disable Tx of fiber port NULL Restore Sequence 1 Fix fault and reconnect 2 Wait for link to be reestablished NULL TABLE 6 CONFIGURATION WITH LLF DISABLED Configu...

Page 17: ...0Base X switch will thus be notified that there has been a copper link loss FIGURE 13 COPPER CONNECTION LOSS Figure 14 is an example of a fiber connection loss If the OSD2153P does not receive a valid optical signal from the switch transmission to copper port will be disabled FIGURE 14 FIBER CONNECTION LOSS OSD2153P 1000Base X Switch Switch or PC Fiber Copper Tx Rx Tx Tx Tx Rx Rx Rx OSD2153P 1000B...

Page 18: ...be damaged by failure of any portion of their support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL INSPECTION Visually check for the following Check that the correct power source is connected to the power socket Check that the Ethernet cables are connected ...

Page 19: ...ive for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the right to repair or replace any faulty goods Freight costs and insurance for both journeys are met by the user All equipment repaired by OSD will have a 3 Month Warranty from the date of dispatch 4 2 ...

Page 20: ...Vuko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N 83 003 020 504 Printed in Australia ...

Reviews: