OPTICAL SYSTEMS DESIGN
DOC ID: 10118201
OSD2139 OPERATOR MANUAL
PAGE 16
2.3
OSD2139 CONNECTIONS
When using the OSD2139 for the first time, check that the unit is in good condition with no visible
damage.
Connect the unit to an appropriate power source and check that the indicators illuminate accordingly on
power up (see Table 4).
For RJ45 connection use Category 5 (CAT5) or higher. Length should be no more than 100 meters.
For singlemode fiber connections, fiber used must be 9/125μm singlemode fiber.
For multimode fiber connections, fiber used must be 50 or 62/ 125μm multimode fiber.
Plug in the appropriate connectors for system configuration;
–
RJ45 cable to fixed copper port and copper SFP module (if used)
–
LC fiber cable to fiber SFP modules.
–
Male DB15 connector for the 2 contact closur and 2 data channels (supplied)
–
5.08mm 2 way terminal block for power connection (supplied)