background image

 

OPTICAL SYSTEMS DESIGN 

 

DOC ID: 10108502 

OSD159 OPERATOR MANUAL

 

 

PAGE 9  

 

2.2.2

 

OSD159 DRAWINGS AND DIMENSIONS 

 
The OSD159 module version is designed to be mounted on an even surface and to be secured by means 
of M4 or smaller screws. The OSD159 card version is designed to be inserted into a chassis and 
secured by means of captivated screws. 
 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

(a)

 

Module Version 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

(b)

 

Card Version 

 
 
 

FIGURE 3: OSD159 MOUNTING DIMENSIONS 

25 

10

210 

R2.1 

R2.1 

Ø8.5 

8.0 

8.0 

DETAIL A

 

6.0 

25.6 

105.5 

6.0

25.6

DETAIL A

50 

113.4 

31.

138.1 

Summary of Contents for OSD159

Page 1: ...OPERATOR MANUAL OSD159 DUPLEX 8 CHANNEL ALARM CONTACT TRANSCEIVER...

Page 2: ...OPTICAL SYSTEMS DESIGN DOC ID 10108502 OSD159 OPERATOR MANUAL PAGE 2 OSD159 DUPLEX 8 CHANNEL ALARM CONTACT TRANSCEIVER Document No 101085 Revision 02...

Page 3: ...12 2 3 1 OSD159 INDICATORS 12 3 MAINTENANCE 13 3 1 INTRODUCTION 13 3 2 EXTERNAL INSPECTION 13 3 3 ROUTINE MAINTENANCE 13 4 WARRANTY 14 4 1 WARRANTY PERIOD 14 4 2 REPAIRS 14 4 2 1 WARRANTY REPAIRS 14 4...

Page 4: ...y powered from and located in the one chassis The module versions are intended for isolated use and require an external power source The OSD159 system can be used with any standard multimode optical f...

Page 5: ...ND OPTIONS There are various options available for the OSD159 as identified in Table 1 below OSD159 example only TABLE 1 PRODUCTS AND OPTIONS ITEM DESCRIPTION Card Version C Standalone Module Version...

Page 6: ...ctor Optical Wavelength 850 40nm for OSD159FM 1310nm 40nm for OSD159FL Transmitter Optical Power 15dBm Receiver Sensitivity 40dBm for 1x10 9 BER Receiver Saturation 7dBm Optical Link Budget 25dB at 85...

Page 7: ...ber Function 1 GND 14 Input 1 2 Input 2 15 Input 3 3 Input 4 16 Input 5 4 Input 6 17 Input 7 5 Input 8 18 Normally Open 1 6 Common 1 19 Normally Open 2 7 Common 2 20 Normally Open 3 8 Common 3 21 Norm...

Page 8: ...e adequate measures OPTICAL OUTPUT OPERATION Class 1 Class 3A The multimode version of the OSD159 is a Class 1 LED product Wavelength of 850nm and 8dBm power output The singlemode versions of the OSD1...

Page 9: ...mounted on an even surface and to be secured by means of M4 or smaller screws The OSD159 card version is designed to be inserted into a chassis and secured by means of captivated screws a Module Vers...

Page 10: ...ernal DC power The voltage range of the OSD159 is 8 to 40VDC or 15 to 26VAC at 3VA maximum Power should be connected to the power socket located at the back of the case as indicated in Table 4 TABLE 4...

Page 11: ...and lint free tissue to remove contamination Receive Alarm is an alarm signal that can be connected to control external sources eg LED indicator to indicate if there is a loss of received signal when...

Page 12: ...tor illuminates accordingly on power up see Table 5 Plug in the optical connectors of the optical cable If the set up is connected correctly the OSD159 Link OK LED will change from Red to Green Plug t...

Page 13: ...heir support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performing maintenance upon the unit 3 2 EXTERNAL...

Page 14: ...e for all repairs 4 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 4 2 2 OUT OF WARRANTY REPAIRS OSD reserves the r...

Page 15: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Reviews: