28
optibelt
TT 3
6
Technical Data
Display
LCD, 2 lines, 16 characters each
Measuring range
10-600 Hz
Measurement accuracy
10-400 Hz:
+/– 1 %
> 400 Hz:
+/– 2 %
Resolution
≤ 100 Hz:
0.1 Hz
> 100 Hz:
1 Hz
Max . entry values
Belt length
< 10 000 mm
Belt weight
< 10 000 g/m
Static belt tension
1- 60 000 N
Sensor
acoustic, with electronic suppression
of interfering noise
Storage capacity
Optibelt data bank: 400
Own data bank:
120
Electricity supply
battery 2 x 1 .5 V AA cells,
optionally
accu 2 .4 V, 1000 mAh
longlife backup of data
(lithium battery)
Electricity consumption
< 20 mA
Temperature range
+5 °C up to +70 °C
Dimensions
205 x 95 x 40 mm (without sensor)
Testing
CE standard
Weight
230 g (not including battery/accumulator)