4.2 Interface Kits 

A series of interface kits is available for operation systems that provide UPS monitoring. 
Each interface kit includes the special interface cable required to convert status signals 
from the UPS into signals which individual operating system recognize. The interface 
cable at UPS side must be connected to REMOTE PORT, at computer side can be either 
COM 1 or COM 2. The other installation instructions and powerful features please refer to 
READ.ME file.

 

CAUTION:

 Use only factory supplied or authorized UPS monitoring cable! 

4.3 The characteristics of computer interface port 

The computer interface port has the following characteristics: 
The communication port on the back of the UPS may be connected to host computer. 
This port allows the computer to monitor the status of the UPS and control the operation 
of the UPS in some cases. Its major functions normally include some or all of the 
following: 
To broadcast a warning when power fails. 
To close any open file before the battery is exhausted. 
To turn-off the UPS. 
Some computers are equipped with a special connector to link with the communication 
port. In addition, special plug-in cord may be needed. Some computers may need special 
UPS monitoring software. Contact your dealer for the details on the various interface Kits.

 

 

5.

 

B

ATTERY 

M

AINTENANCE

 

5.1 Battery maintenance 

For the preventive maintenance, keep the area around the UPS clean and duty-free. 
Please also keep the UPS at ambient temperature of 25

 (77

).

 It is recommend that 

the batteries charge for 24 hours after long storage.

 

5.2 Storage 

To store UPS, cover it and store it with the battery fully charged. During extended storage, just 
connect the utility power to recharge the battery every three months to ensure battery life. 

A

PPENDIX A 

T

ROUBLESHOOTING

 

 

Problems Possible 

Cause 

Solution 

Full-time Bypass 
Protection outlets 
stop providing 
power to the 
equipment 

Circuit breaker button popped up as 
a result of overload. 

Unplug at least one piece of equipment 
from the Full-time Surge Protection 
outlets. 
Switch off UPS, wait 5 seconds, reset the 
circuit breaker (press down breaker 
button), then switch on UPS. 

Battery undercharged or depleted 
due to frequent power outages. 

Recharge the battery by leaving the UPS 
plugged in and switched on. 

The power required by your 
equipment slightly exceeds the 
capacity of the UPS. 

Unplug at least one piece of equipment 
from the UPS outlets. 

UPS doesn’t 
perform to its 
expected runtime. 

The battery is slightly worn-out. 

Consider replacing the battery. 

The battery is worn-out. 

Replace the battery the instructions in this 
manual. 

UPS cannot be 
turned on.

 

Mechanical problem. 

Contact your sales representative. 

 

 

-  - 

7

A

PPENDIX B 

S

PECIFICATIONS

 

 

MODEL 

CS385B CS530B CS730B 

UPS Capacity(VA/W) 

385VA/190W

530VA/265W

730VA/365W 

No. of sockets 
(NEMA 5-15R) 

2 Battery 

Backup 

2 Battery         

2 Surge Protection 

Voltage (on battery) 

Simulated sine wave at 100V/115V/ 220V/      

240V +/-5% AVR Controlled by PWM 

Frequency (on battery) 

50 or 60Hz +/- 0.3Hz 

Output 

Transfer Time 

<10 milliseconds, including detection time 

Voltage (single phase) 

100V +/-20%, 110V +/- 25%,   

220V/230V/240V, 170V~280 at line input

 

Input 

Frequency   

50 or 60Hz +/- 10% (auto sensing) 

Unit Input 

Circuit breaker for overload & short circuit protection 

Overload Protection 

UPS automatic shutdown if overload exceeds 110% 

of nominal at 10 seconds, 120% at 3 seconds 

Short Circuit 

UPS output cut off immediately   

Protection 
 

Spike Protection 

460 Joules(MAX.), 2ms 

Type 

Sealed, maintenance-free lead acid batteries with 3-5 

years typical lifetime 

Typical Recharge Time 
(to 90% of full capacity) 

6 hours   

Battery 

Protection 

Automatic itself-test, Over discharge protection, short 

circuit protection by fuse 

Weight (Net)                     

3.53 lbs     

1.6 kgs 

5.73 lbs                       

2.6 kgs 

Physical 

Dimensions (L×W×H)    

3.74×3.74×6.22 

inches     

95×95×158 mm

3.74 × 5.43 × 6.22 inches         

95 × 138 ×158 mm 

Interface 

Communication Port 

USB port 

Battery Back-Up 

Slow beeping sound every 4 seconds (Buzzer can be 

muted by pressing main switch button) 

Battery Low 

Continue beeping sound every second 

100% load 

Continue beeping sound every 4 second 

Alarm 

Overload 

Continue beeping sound 

Ambient operation 

3,500 meters max. elevation, 0-95% humidity 

(non-condensing water), 0-40

 

Environment 

Audible Noise 

<40dBA (1 meter from surface) 

 
 
 

Summary of Contents for Clever CS385B

Page 1: ...cords The serial number of your UPS is on the rear panel You should note the serial number in the space provided below Retain this booklet as a permanent record of your purchase to aid in identification in the event of theft or loss Model No Serial No Purchase Date ...

Page 2: ... our specifications g Normal wear and tear h Any other cause which does not relate to a product defect 3 Removal installation and set up service charges Limitation of implied warranties THERE ARE NO WARRANTIES EXPRESS OR IMPLIED WHICH EXTEND BEYOND THE DESCRIPTION CONTAINED HEREIN INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Exclusion of damages OUR LIABIL...

Page 3: ... remove cover No user serviceable parts inside Refer servicing to qualified service personnel CAUTION Do not dispose of batteries in a fire the battery may explode CAUTION Do not open or mutilate the battery released electrolyte is harmful to the skin and eyes It may be toxic CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be ob...

Page 4: ...taneous back up power and full time bypass protection to your equipment Ensure temporary uninterrupted operation of your equipment during power failure 1 4 Full time Bypass Protection Outlets Provide full time Bypass protection to your equipment Prevent surge from traveling through your system through unprotected peripherals 1 5 Power button ON OFF TEST SILENCE The UPS can be turned on while press...

Page 5: ...irst time or when adding an additional piece of equipment Conduct a simulation test first switch on UPS and wait for the power indicator to light up then simply unplug UPS to simulate the event of utility failure 5 3 2 Check the power requirement of your equipment 3 2 1 Make sure the total power of your equipment does not exceed rating capacity 3 2 2 Also make sure the equipment you plugged into t...

Page 6: ...urge Protection outlets Switch off UPS wait 5 seconds reset the circuit breaker press down breaker button then switch on UPS Battery undercharged or depleted due to frequent power outages Recharge the battery by leaving the UPS plugged in and switched on The power required by your equipment slightly exceeds the capacity of the UPS Unplug at least one piece of equipment from the UPS outlets UPS doe...