Requirements 

This document is provided as a reference  tool for installing the 

Optex Redwall SIP passive infrared detector. Before starting, 

read the instruction book that comes with the unit. 

SIP detector main unit 

Cross slot 

Screwdriver 

 Page 1/18 

REDWALL-V adjustment procedures guide 

Ver1.2  July 1. 2011 

*Included

 

in the kit 

Area plate 

Area masking seal 

Allen Key 

Tweezers  

*Optional (but necessary) 

adjustment tools 

AVF-1               

Area View 

Finder         

AWT-3                       

Area Walk 

Tester 

*Other useful tools 

Measure             

wheel 

Before starting any installation, please confirm if 

proper power is provided to the SIP unit. 

Volt meter 

Summary of Contents for REDWALL-V

Page 1: ...ector main unit Cross slot Screwdriver Page 1 18 REDWALL V adjustment procedures guide Ver1 2 July 1 2011 Included in the kit Area plate Area masking seal Allen Key Tweezers Optional but necessary adj...

Page 2: ...e unit 10 Walk testing to confirm the obstacle s location 11 Mounting the AVF 1 for false alarm avoidance 12 Recording the obstacle s location 13 Preparation of masking 14 Masking the optics 15 Settin...

Page 3: ...vertical position with Angle Adjustment guide according to installation height Arrow of the main unit Installation height at 2 3m 7 6ft Installation height at 4m 13ft If the height is between 2 3m an...

Page 4: ...rizontally to desired area 3 Tighten the adjustment screw slightly Remove the cover before mounting the AVF 1 View Finder 1 Loosen two securing screws 2 Hold the head of the both screw with your hand...

Page 5: ...AVF 1 to the main unit 3 Peel off the protection seals from both sides of the area plate 4 Insert the area plate into the slot of View Finder so that the arrow points up 5 Look through the inspection...

Page 6: ...o get the position that the person is located in the most far detection area 4 Make a person stand at the point Actual site view View through the AVF 1 1 Adjust the horizontal angle of the main unit i...

Page 7: ...ogic selector is OR Step7 Preparation for walk test 2 Confirm that CONNECTION SELECT SWITCH is at REDWALL V 3 MODE SELECT SWITCH is used for Far Near and Creep zone detection 3 2 Step6 Setting the AWT...

Page 8: ...the condition in the detection area 2 Check to ensure the tone is constant that there is no one in the detection area If not there might be an object that could be the cause of a false alarm Remove t...

Page 9: ...or F6 1 and 2 should be masked Record F6 1 and 2 for masking Step11 Mounting the AVF 1 for false alarm avoidance AVF 1 AWT 3 Remove the AWT 3 from the unit and then put the AVF 1 on the unit again Con...

Page 10: ...that of the detection segment of AVF 1 What is seen on the left is physically on the right side of the mirror For example in Step12 segment F6 should be masked like below 1 Remove the AVF 1 2 Remove...

Page 11: ...Confirm which mirror should be masked by area chart If some object covers the zone 1 and 2 opposite side of mirror needs to be masked photo above Masking the Far Area Detection There are 2 options whe...

Page 12: ...tion There are 2 options when masking the Near Area detection a Use Masking plates to narrow detection area Like far area take the masking plate out and mask outside detection area But you can mask th...

Page 13: ...Detection b Use Masking Seals to eliminate specific unwanted segment Note This is a permanent countermeasure 1 Confirm obstacle s location F6 recorded through Step12 2 Attach carefully the masking sea...

Page 14: ...in Step16 Conduct walk test to confirm successful masking Confirm the unwanted segments are properly eliminated Check both Far area and Near area independently If the tone doesn t change when a person...

Page 15: ...e screw and remove the lid of creep unit 2 Adjust the detection angle horizontally and vertically 3 Conduct walk test whether the detection area has been set as required If not re adjust it 4 Put the...

Page 16: ...wo detection areas AND When conducting Walk test please set at SH In case that the SIP installed at 2 3m 7 6 Factory default is M position After confirmation of the detection area adjust the proper se...

Page 17: ...he AWT 3 put the cover on the main unit and fasten the securing screw Step19 Walk testing to reconfirm the detection area Conduct a walk test to confirm the SIP detects a person in the detection area...

Page 18: ...o copyright owned by OPTEX CO LTD You may not copy communicate to the public adapt distribute modify or publish any contents of this document without the express prior written consent of OPTEX CO LTD...