background image

 

TROUBLESHOOTING

 

Note

   The door may open once after the power is switched on.

Inform the following items to the building
owner/operator

1. When turning the power on, always walk-test the sensor pattern to ensure proper operation.
2. Always keep the detection window clean. If dirty, wipe the window with a damp cloth ( Do not use any cleaner or solvent ).
3. Do not wash the sensor with water.
4. Do not disassemble, rebuild or repair the sensor yourself; otherwise electric shock may occur.
5. Contact your installer or the sales engineer if you want to change the settings.
6. Do not place an object that moves or emits light in the detection area.(ex. Plant,  illumination etc..)
7.  Do not paint the Detection Window.

Contact your installer or the sales engineer if:
 - you need to change the settings or replace the sensor.
 - the trouble still persists after checking and remedying as described above.

Secumatic b.v.

Tiber 2. 2491, DH The Hague, P.O. Box 24009 2490, AA The Hague
The Netherlands
TEL.: +31 (0)70 419 41 00      FAX: +31 (0)70 317 73 21
E-MAIL: [email protected]    WEBSITE:  www.secumatic.nl

Entry motion

Power OFF

Outside the Detection
area

(image)

Sensor status

Power OFF

Stand-by

Entry into the Detection
area

Motion or Presence
Detection Active

Stand-by

Red

Green

Yellow
Green
White

Output

Opertion indicator

Green

OFF

Yellow
Green
White

Yellow
Green
White

Does not
operate

Dose not
operate
consistently

Operates by
itself

Power supply is not adequate.
Connection  Failure.

Dirty detection window.

Sensitivity is Low.

There is an object that moves or emits light in the
detection area.(ex. plant, illmination etc...)

Vibration of the header.

Sensitivity is high.

Waterdrops on detection window.

Detection area has interfered the area of
another sensor.

The Emitting spots are overlapping with the door
/ header.

Keep
operating

There is an reflected object in the detection area.
Solar light reflects.

Presence timer is Infinity. There was an abrupt
condition change in the detection area.

Adjust to stated voltage.
Check the wiring and the connector.

Wipe the detection window with a damp cloth( Do not
use any cleaner or solvent ).
Set the Sensitivity Switch “ H ” .

Set the Sensitivity Switch “ L ” .

Remove the object.

Remove the object.

Secure the header. Or set the Sensitivity Switch “ L ” .

I

nstall in a place keeping the waterdrops off. OR

use a rain-cover (Optional).

Set the different frequency position each other.

Adjust the detection area to deep (outside).

Turn the power off and on again.

Trouble

Possible Cause

Solution

 

CHECKING

Check the operation according to the chart below.

There was a puddle left by rain or snow.
The floor has gotten wet.

The exhaust of the car and the fog penetrate into
the detection area.

This sensor is equipped with the anti-malfunction.
However, pay attention when installing as malfunction
may occur under the left conditions.

Yellow
Green
White

Outside the Detection
area

Reviews: