background image

MANUFACTURER’ S  STATEMENT

OA-Presence

Read this Operation Manual carefully before use, to ensure proper operation of this  Optex sensor.
Failure to read this Operation Manual may cause improper sensor operation and may result in serious injury or death.
This product is a non-contact activating switch intended for mounting on the header of an automatic door.
Do not use it for any other applications; otherwise proper operation and safety cannot be guaranteed.
Cautions:
1. Follow the instructions (especially   

Note

  ) in this Operation Manual when installing and adjusting the sensor.

2. When setting the sensor's area pattern, make sure there is no traffic around the installation site.
3. Before turning the power on, check the wiring to prevent damage or malfunction of equipment that is connected to the sensor.
4. Do not wash, disassemble, rebuild or repair the sensor by yourself; otherwise it may cause electric shock or breakdown of the

sensor.

5. Only use the sensor as specified in the supplied instructions.
6. Be sure to install the sensor in accordance with the local laws and standards of your country.
7. Before leaving the jobsite, be sure that this sensor is operating properly and instruct the building owner/operator on proper

operation of the door and this sensor.

Model
Cover color type
Mounting Height
Detection Area
Detection Method
Detection Angle
       Adjustments
Detection Width
        Adjustments
Power Supply
Current Draw
Operation  Indicator

*The specifications herein are subject to change without
  prior  notice due to improvements.

 : OA-Presence
 : Silver / Black / White
 : 3.0m(9’10”) Max.
 : See “Detection Area”
 : Active Infrared Reflection Method
 : ±4

 

adjustable by 1

 

 every one click

     (Deep / Shallow )
 : ±7

 

adjustable by 3.5

 

every one click

      ( Right / Left )
 : 12 to 30V AC / DC
 : 160mA Max. (at 12V AC)
 : Green  / Stand-by
   Red     /  Detection Active

SPECIFICATIONS

Output Method

Relay Hold Time
Response Time
Operating Temperature
Weight
Accessories

 : “Form C” relay 50V 0.3A Max.
   (Resistance Load)
 : 0.5 sec.
 : < 0.3 sec.
 :  -20°C to +55°C ( -4°F to +131°F )
 : 200g (7.1oz)
 : 1  Cable 3m (9’10”)
   2  Mounting Screws
   1  Operation Manual
   1  Mounting Template
   1  Area Adjustment Tool

5911630 2004.5

OUTER DIMENSIONS

1 : Connector

2 : Sensitivity Switch

3 : Mounting holes

4 : Dipswitches

5 : Area Adjustment Tool

6 : Area Adjustment Screw

7 : Width Adjustment Shutters

8 : Operation Indicator

9 : Detection Window

mm (inch)

Reviews: