Arm/Home 

1 beep* 

3 LED flashes once 

Disarm 

2 beeps* 

Sequentially flashes for 1 cycle 

Arm (Low Battery) 

5 beeps 

3 LED flashes for three times 

Disarm (Low Battery) 

5 beeps 

Sequentially flashes for 2 cycles 

Arm (Tamper) 

5 beeps 

3 LED flashes for three times 

Disarm (Tamper) 

2 beeps* 

Sequentially flashes for 2 cycles 

Previous alarm warning 

3 secs beep 

Sequentially flashes for 2 cycles 

Entry/Exit Sound 

Count-down 

beeps 

None 

 

POWER SUPPLY 

The Bell Box is powered by 4 x D-cell alkaline batteries. It also features low battery voltage detection. When low battery is detected, a low battery signal 
will be sent to the Control Panel along  with regular signal transmissions for the Control Panel to  display the  status accordingly. The Bell  Box  will also 
emit 5 beeps when armed/disarmed to notify the user of low battery condition. 
 

SUPERVISION FUNCTION 

When the Dip Switch #7 is slid to ON position, the Bell Box will conduct a Self-test Periodically by transmitting a supervisory signal once every 30-50 
mins in normal operation mode. 
If this signal is not received, the Control Panel will determine the particular Bell Box is out-of-order and report the event accordingly. 
 

FUNCTION OVERVIEW 

SIREN AUDIBLE PERFORMANCE 

The siren produces a minimum of 104 dBA sound pressure at 1 meter range when activated.

 

 

 

For Burglar and Panic Alarm, the Bell Box gives a continuous alarm sound.  
For Fire / Water alarm, the Bell Box gives an intermittent alarm sound of 2-sec siren followed by a 1 sec interval.  

N

N

O

O

T

T

E

E

>

>

>

>

 

 

  The siren is silenced when either the programmed siren length expires or when the Control Panel is disarmed to turn off the siren. Please refer 

to Dip Switch table above to set your desired alarm length through Dip Switch SW3 and SW4 setting. 

 

STROBE (LED) LIGHT 

When the Bell Box is activated, the LED strobe light will also flash to indicate the Bell Box is alarming. The duration of strobe light flash is determined by 
Dip Switch SW2 setting. When set to OFF, the strobe light will flash according to the alarm length set by Dip Switch SW3 and SW4. When set to ON, the 
strobe light will flash after the alarm length has expired until the control panel is disarmed. 
 

ALARM MEMORY 

If an alarm was triggered in your absence and the system was not disarmed before alarm length expiry, the Bellbox will sound a short alarm when the 
system is disarmed to warn the user that an alarm has been triggered when he is away. This suggests that the intruder could still be within the premises. 
 

ALARM LENGTH 

When an alarm is activated by Control Panel, the Control Panel will notify the Bellbox to start alarming according to the panel’s own alarm length setting. 
When the Panel’s alarm length expires, it will notify the Bellbox to stop alarm. 
The Bellbox’s own alarm length setting,  which is set by Dip Switch SW3&4, determines how long the Bellbox should activate alarm if no stop signal is 
received from Control Panel: 

For example 

  If the Panel alarm length is set longer than Bellbox alarm length, after an alarm is activated, instead of waiting panel alarm length to expire, the 

Bellbox will stop alarming upon expiry of its own alarm length. 

  If  the panel is  under disarm mode  and the  Bellbox tamper switch  is triggered,  the  Bellbox  will  activate alarm according to its  own  alarm length 

setting since the panel is under disarm mode and will not activate alarm from tamper trigger. 

 

TAMPER PROTECTION 

The Bellbox is protected against any attempt to open the lid or to detach the bellbox from its mounting surface. 
If the Bellbox  detects a  tamper condition,  it will activate the siren &  strobe light for the programmed alarm period.  A tamper signal will be sent to the 
Control Panel along with regular signal transmissions for the Control Panel to display the status accordingly. If the tamper condition persists, the Bellbox 
will sound a series of five beeps either every time the system is armed or when the tamper is enabled, to indicate a fault. 
Tamper  feature  can  be  disabled  temporaily  from  the  Control  Panel  using  Siren  Tamper  control  function.  The  Bellbox  will  stop  tamper  detection 
temporarity  for  one  hour.  This function  is  mainly  designed  for  replacing  battery  or  changing  Bellbox  installation  location.  After  one  hour,  The  Control 
Panel will automatically turn the function back ON after the duration. The tamper detection can also be enabled again manually using the Siren Tamper 
function. 
 

AUDIO & VISUAL STATUS INDICATION TABLE 

The Bell Box will activate its siren and strobe light to notify the user of 
system status, please refer to the table on the right. 

N

N

O

O

T

T

E

E

>

>

>

>

 

 

 

 

Siren Audio indication will be affected by the Confirmation 
ON/OFF setting in your Control Panel settings. 

 

FACTORY RESET 

The  siren  can  be  reset  and  memory  contents  cleared  by  following 
steps. 

Step1. 

Remove the learnt-in Bell Box from Control Panel, refer 
to the operation manual of your Control Panel for details. 

Step2. 

Remove the Bell Box front cover. 

Step3. 

Slide the power switch to Off position, and then press the tamper switch once for discharging.   

Step4. 

Set DIP SW 6 to ON position and put the power switch to ON position. The siren will produce a short confirmation tone.  

Step5. 

Slide DIP SW 6 to OFF position. The Bell Box returns to normal mode.  

 

GETTING STARTED 

LEARNING THE BELL BOX 

Step1. 

Release the screws at the bottom of the Bell Box and pull the outer case out carefully. Locate the Function Switch Block. 

Step2. 

Use a sharp object to slide Dip SW3 & SW4 on the Bell Box function switch block for your desired alarm length. 

Step3. 

Put the Control Panel into the learning mode, refer to Control Panel manual for detail.  

Step4. 

Slide Dip SW1 on the Bell Box function switch block to ON position. The LED 1 & 3 flash once with a short beep. The Bell Box is now in  
learning mode. After 3 seconds, the Bell Box will send out a learning code indicated by all 3 LED flashing.  

Step5. 

If the Control Panel fails to receive a learning code, slide Dip SW1 back to OFF and then ON position to enable Bell Box to enter the 
learning mode again. Repeat the rest of the learning process. 

Step6. 

If the Control Panel receives the learning code, it will display Bell Box information accordingly. Refer to Control Panel manual to complete 
learning process.  

Step7. 

After learning is completed, an acknowledgement signal will be sent to the Bell Box.  When the acknowledgment is received, the Bell Box 
sounds a short beep with LED 1&3 flashing once to indicate that learning process is successful.  

N

N

O

O

T

T

E

E

>

>

>

>

 

 

Reviews: