1
2
4
3
5
SW1
Siren Learning
OFF
Normal operation
ON
Learn-in mode
SW2
Strobe Activation
OFF
only during siren alarm period
ON
until alarm is disarmed
SW3
SW4
Alarm Length
OFF
OFF
3 min.
ON
OFF
5 min.
OFF
ON
10 min.
ON
ON
1 second (test)
SW5
Reserved
SW6
Memory Reset
OFF
Normal
ON
Clear Memory
SW7
Supervision
OFF
Supervision function disable
ON
Supervision function enable
1
BEFORE INSTALLATION
Warning
Failure to follow the
instructions provided
and improper handling
may cause death or
serious injury.
Do not touch the unit base or power terminals of the product with a wet hand. (Also, if the product is wet
after rain, do not touch it.) It may cause electric shock.
Never attempt to disassemble or repair the product. It may cause fire or damage to the devices.
[Handling of Batteries]
Fire, explosion and severe burn hazard. Do not recharge, short circuit, crush, disassemble, heat above 100°C,
Incinerate, or expose contents to water. Do not solder directly to the cell.
Caution
Failure to follow the
instructions provided
and improper handling
may cause injury and/or
property damage.
Do not pour water over the product. The water may enter and may cause damage to the devices.
Clean and check the product periodically for safe use. If any problem is found, do not attempt to use the product
as it is and inform your installer.
If you do not use the product for a long period of time, remove the battery. Keep it in a cool, dark area.
Dispose batteries according to local regulations.
This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.
This symbol requires an action or gives an instruction.
The Outdoor Bell is used to attract attention when alarm signal is received from Control Panel, by activating its siren and strobe light.
The Bell Box has built-in tamper protection and low battery detection to monitor its operation status.
2
PARTS IDENTIFICATION
1.
Mounting Holes x 4
2.
Tamper Switch
The tamper switch protects the device from being opened or from being removed from mounting surface.
3.
Function Switch Block
Contains 7 DIP Switches to enable the learning mode and to set the alarm period of siren and strobe light.
4.
Securing Screw
To secure the cases from being open.
5.
Power Switch
To enable/disable the power supply
3
ACCESSORIES INCLUDED
In addition to the Bell Box, the following accessories are also included in the package
large wall plugs: 4
4x30 cross head fixing screws: 4
1.5V D alkaline cells: 4
4
DIP SWITCH POSITION TABLE
Remove the cover by unscrewing the single screw located at the bottom. In the middle
of the L-shaped PCB board, you can see a Jumper Switch Block which consists of 7
DIP Switches. The function of each DIP Switch is listed in the table on the right.
The DIP Switch is either ON or OFF. Top position indicates ON and bottom position
indicates OFF.
For further detail please see section
Function Overview.
INSTALLATION INSTRUCTIONS
ON
OFF
592536-0