background image

+

+

+

+

1

2

4

3

5

 

SW1  

 

Siren Learning 

OFF 

 

Normal operation 

ON 

 

Learn-in mode 

SW2 

 

Strobe Activation 

OFF 

 

only during siren alarm period 

ON 

 

until alarm is disarmed 

SW3 

SW4 

Alarm Length 

OFF 

OFF 

3 min. 

ON 

OFF 

5 min. 

OFF 

ON 

10 min. 

ON 

ON 

1 second (test) 

SW5 

 

Reserved 

SW6 

 

Memory Reset 

OFF 

 

Normal 

ON 

 

Clear Memory 

SW7 

 

Supervision 

OFF 

 

Supervision function disable 

ON 

 

Supervision function enable 

 

 
 
 
 
 
 
 
 
 
 

BEFORE INSTALLATION  

 

Warning 

Failure to follow the 
instructions provided 
and improper handling 
may cause death or 
serious injury. 

Do not touch the unit base or power terminals of the product with a wet hand. (Also, if the product is wet  
after rain, do not touch it.) It may cause electric shock. 

Never attempt to disassemble or repair the product. It may cause fire or damage to the devices. 

[Handling of Batteries] 
Fire, explosion and severe burn hazard. Do not recharge, short circuit, crush, disassemble, heat above 100°C, 
Incinerate, or expose contents to water. Do not solder directly to the cell. 

Caution 

Failure to follow the 
instructions provided 
and improper handling 
may cause injury and/or 
property damage.  

Do not pour water over the product. The water may enter and may cause damage to the devices. 

Clean and check the product periodically for safe use. If any problem is found, do not attempt to use the product 
as it is and inform your installer. 

If you do not use the product for a long period of time, remove the battery. Keep it in a cool, dark area. 

Dispose batteries according to local regulations. 

 

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure. 

 

This symbol requires an action or gives an instruction.  

 
 

The Outdoor Bell is used to attract attention when alarm signal is received from Control Panel, by activating its siren and strobe light. 
The Bell Box has built-in tamper protection and low battery detection to monitor its operation status.  

 

PARTS IDENTIFICATION 

1. 

Mounting Holes x 4 

2. 

Tamper Switch 

The tamper switch protects the device from being opened or from being removed from mounting surface. 

3. 

Function Switch Block 

Contains 7 DIP Switches to enable the learning mode and to set the alarm period of siren and strobe light. 

4. 

Securing Screw 

To secure the cases from being open. 

5. 

Power Switch 

To enable/disable the power supply 

 

 

 

 

 

ACCESSORIES INCLUDED 

In addition to the Bell Box, the following accessories are also included in the package 

  large wall plugs: 4 

  4x30 cross head fixing screws: 4 

  1.5V D alkaline cells: 4 

 

DIP SWITCH POSITION TABLE 

Remove the cover by unscrewing the single screw located at the bottom. In the middle 
of the L-shaped PCB board, you can see a Jumper Switch Block which consists of 7 
DIP Switches. The function of each DIP Switch is listed in the table on the right. 
The  DIP  Switch  is  either  ON  or  OFF.  Top  position  indicates  ON  and  bottom  position 
indicates OFF.  
 

 

 

 

 

 

 

 

 

 For further detail please see section

 Function Overview.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS 