1
BEFORE INSTALLATION
Warning
Failure to follow the
instructions provided
and improper handling
may cause death or
serious injury.
Do not touch the unit base or power terminals of the product with a wet hand. (Also, if the product is wet
after rain, do not touch it.) It may cause electric shock.
Never attempt to disassemble or repair the product. It may cause fire or damage to the devices.
[Handling of Batteries]
Fire, explosion and severe burn hazard. Do not recharge, short circuit, crush, disassemble, heat above 100°C,
Incinerate, or expose contents to water. Do not solder directly to the cell.
Caution
Failure to follow the
instructions provided
and improper handling
may cause injury and/or
property damage.
Do not pour water over the product. The water may enter and may cause damage to the devices.
Clean and check the product periodically for safe use. If any problem is found, do not attempt to use the product
as it is and inform your installer.
If you do not use the product for a long period of time, remove the battery. Keep it in a cool, dark area.
Dispose batteries according to local regulations.
This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.
This symbol requires an action or gives an instruction.
The Door Contact monitors the opening/closing of specified devices (e.g. door or window). The Door Contact is fixed to the monitored device frame with
an actuating magnet fixed to the device. When the door or window opens, the magnet moves away from the Door Contact, activating an internal
magnetic switch causing the Door Contact to transmit alarm signal to the Central Panel. The device also has the capabilities of communicating signal
problems along with low battery situations.
The Door Contact design consists of a cover and base. The cover contains all electronics and the base provides a means for fixing the device. An
enclosed PCB tamper switch provides tamper protection against unauthorized device opening and/or removal.
2
PARTS IDENTIFICATION
1.
LED indicator / Test button
Press the Test button to transmit learning code or enter test mode for 3 min.
2.
Mounting Holes
Used to fixed and screw the Door Contact directly onto the Door Frame or Wall.
3.
Battery Insulator
4.
Tamper Switch
Provides tamper protection against unauthorized device opening and/or removal from mounting surface.
Internal Switch and Terminal
Loosen the bottom fixing screw and remove the cover to reveal terminal as shown.
5.
Extension Terminal
In addition to the built-in magnet switch, an additional 2-pin dry contact terminal is provided
for an extension
magnet switch
or any device with N.C. (Normally Closed) functionality.
6.
Supervision Jumper Switch (JP2)
When the jumper is set as OFF, the Supervision function is enabled.
(Factory Default)
433FM-F1 and 868FM-F1 does not have this Jumper installed and Supervision is alwas enabled
7.
Internal Magnetic Switch Jumper Switch (JP3)
When the jumper is set as ON, the Internal Magnetic Switch is disabled. Only the device connected to
Extension Terminal will activate the Door Contact
When the jumper is set as OFF, the Internal Magnetic Switch is enabled.
(Factory Default for all models)
8.
Magnet
Mount the magnet on the side of the Door Contact where it has 2 rib-marks to indicate the position of the internal
magnet switch. The Door Contact should be installed either upright or inverted to ensure that the rib-marked side
faces the magnet.
9.
Magnet Spacer
3
ACCESSORIES INCLUDED
1 Magnet and Magnet Spacer
2 White Caps
Screws
2 Wall Plugs
1 Magnet double-sided adhesive tape pad
Jumper On
The jumper link is inserted
Jumper Off
if the jumper link is removed or “
parked
” on one pin.
INSTALLATION INSTRUCTIONS