Page 52
Confidential
– Limited Distribution
SUMA Flash Testing
Step 1
With the SUMA completed and enclosure lid fully secured using a 3/8 in (9.5 mm) nut
driver, remove the air valve cap from the cover.
-
Figure 62. The air valve location
Step 2
Pressurize the enclosure up to 5 psi. A pump and pressure gauge will be needed.
Figure 63. Pressurizing the SUMA using a pump with gauge
CAUTION:
Do not exceed 5 PSI when pressurizing the SUMA.
Air Valve