Setp 5
Step 3
Step 2
Step 1
6. Remove the template and securely fasten the sensor head to the
door using two mounting screws.
7. Repeat this process for each door leaf.
Step 4
Wiring Cover
Wiring Base
Making top of Wiring Base
Push it from the upper part a little.
Slide it from the upper part downward.
1. To attach the position sensor/door loop to the base
plate, route the sensor connector wire and change the
direction of the wiring cover based on hinge location
when facing the door (LH or RH see pictures below).
3. Drill four sensor mounting holes (two on each side of door leaf, 1/8” or 3.2 mm)
as indicated by templates.
4. Drill 3/8" holes for pass thru cable as indicated on templates.
Hole "A" on approach side templete should be perfectly in line with
hole "A" on swing side template.
1. Determine which side of door(swing or non-swing) door loop is too be installed. Align template to pivot edge of door accordingly.
Affix template. Template height can be between 6'-7" to 8'-2" from floor to top of template.
When templates are aligned properly the 3/8" pass thru hole ( "A" on template) will be aligned with each other on both sides of door.
2. On side of door the door loop is to be installed, drill two
1/8"(3.2mm) holes for position sensor mounting plate as indicated
by template (one side of door leaf only).
1. On the side of the door where the door loop is to be installed take a
603 sensor head and adjust the left and right dipswitch settings as indi-
cated by the corresponding template. Verify Threshhold and Swing angle
adjustments are set to Deep (+5 degrees).
2. Remove the template and attach the sensor head loosely to the door
leaf with two of the nine supplied screws.
3. Align the position sensor mounting plate with the appropriate mounting
holes and securely fasten to the door leaf with two mounting screws.
4. Go back and tighten the screws securing the 603 sensor head to the door.
5. On the opposite side of the door leaf, take a 603 sensor head and set
the left and right dipswitch settings as indicated by the corresponding
template. Verify Threshhold and Swing angle adjustments are set to
Deep (+5 degrees).
EACH TEMPLATE LOCATION WILL HAVE DIFFERENT DIPSWITCH SETTINGS.
NOTE
2. To attach to base plate locate the position sensor slightly high and to the side
of the plate. Slide in horizontally and then down vertically .
1.To properly locate the door jamb wiring base, slide the wiring cover on to the wiring
base and center it from top to bottom.
2.Hold wiring base on jamb rotate door from closed to full open. Ensure no excessive
streching or binding of the loop occurs (may need to move base up or down to
achieve.) Mark top of wiring base to align mounting template later.
Wiring Cover
LH
RH
LH
RH
1.Align and affix top of template with mark achieved in step 4..
2.Drill two 1/8" (3.2mm) mounting holes. Drill 3/8" (10mm) hole if routing cable thru jamb for concealed wiring (3/8" hole not required for surface
wiring applications).
1-3
NOTE
These settings are optimal for most applications. However, operating condi-
tions, environmental conditions and traffic flow may require changes to these
settings. For in depth explanations of adjustments and dipswitch settings refer
to the adjustment section (page 1-5) of this manual.
0deg
+5deg
‑5deg
DEEP
SHALLOW
DEEP
SHALLOW
DEEP
PATTERN
SHALLOW
PATTERN
0deg
+5deg
‑5deg
DEEP
SHALLOW
DEEP
SHALLOW
DEEP
PATTERN
SHALLOW
PATTERN
NOTE