background image

Setp 5

Step 3

Step 2

Step 1

6. Remove the template and securely fasten the sensor head to the 

door using two mounting screws.   

7. Repeat this process for each door leaf.

Step 4

Wiring Cover

Wiring Base

Making top of Wiring Base

Push it from the upper part a little. 

Slide it from the upper part downward. 

1. To attach the position sensor/door loop to the base 
plate, route the sensor connector wire and change the 
direction of the wiring cover based on hinge location 
when facing the door (LH or RH see pictures below).

3. Drill four sensor mounting holes (two on each side of door leaf, 1/8” or 3.2 mm)

as indicated by templates.

4. Drill 3/8" holes for pass thru cable as indicated on templates.

                    Hole "A" on approach side templete should be perfectly in line with

                    hole "A" on swing side  template.

1. Determine which side of door(swing or non-swing) door loop is too be installed. Align template to pivot edge of door accordingly.

Affix template. Template height can be between 6'-7" to 8'-2" from floor to top of template.

             

     

When templates are aligned properly the 3/8" pass thru hole ( "A" on template) will be aligned with each other on both sides of door.             

2. On side of door the door loop is to be installed, drill two 

1/8"(3.2mm) holes for position sensor mounting plate as indicated 

by template (one side of door leaf only).

1. On the side of the door where the door loop is to be installed take a 

603 sensor head and adjust the left and right dipswitch settings as indi-

cated by the corresponding template.  Verify Threshhold and Swing angle 

adjustments are set to Deep (+5 degrees).

2. Remove the template and attach the sensor head loosely to the door 

leaf with two of the nine supplied screws.  

3. Align the position sensor mounting plate with the appropriate mounting 

holes and securely fasten to the door leaf with two mounting screws.  

4. Go back and tighten the screws securing the 603 sensor head to the door.

5. On the opposite side of the door leaf, take a 603 sensor head and set 

the left and right dipswitch settings as indicated by the corresponding 

template.  Verify Threshhold and Swing angle adjustments are set to 

Deep (+5 degrees).

EACH TEMPLATE LOCATION WILL HAVE DIFFERENT DIPSWITCH SETTINGS.

NOTE

2. To attach to base plate locate the position sensor slightly high and to the side 
of the plate.  Slide in horizontally and then down vertically .

1.To properly locate the door jamb wiring base, slide the wiring cover on to the wiring
base and center it from top to bottom.
2.Hold wiring base on jamb rotate door from closed to full open. Ensure no excessive 
streching or binding of the loop occurs (may need to move base up or down to 
achieve.) Mark top of wiring  base to align mounting template later.

Wiring Cover

LH

RH

LH

RH

1.Align and affix top of template with mark achieved in step 4..
2.Drill  two 1/8" (3.2mm) mounting holes. Drill 3/8" (10mm) hole if routing cable thru jamb for concealed wiring (3/8" hole not required for surface 
wiring applications).

1-3

NOTE

These settings are optimal for most applications.  However, operating condi-

tions, environmental conditions and traffic flow may require changes to these 

settings.  For in depth explanations of adjustments and dipswitch settings refer 

to the adjustment section (page 1-5) of this manual.   

0deg

+5deg

‑5deg

DEEP

SHALLOW

DEEP

SHALLOW

DEEP

PATTERN

SHALLOW
PATTERN

0deg

+5deg

‑5deg

DEEP

SHALLOW

DEEP

SHALLOW

DEEP

PATTERN

SHALLOW
PATTERN

NOTE

NOTE

Summary of Contents for Elite OA-603

Page 1: ...6 7 8 9 9 10 MANUFACTURER S STATEMENT For ease of installation and proper operation read thru this manual especially WARNING CAUTION NOTE prior to installing and adjusting the sensor system Failure t...

Page 2: ...wing CLOCKWISE to achieve maximum angle for all door mount sensor The screws will continue to turn even though maximum angle is reached as indicated by the angle gauges Please refer to the following f...

Page 3: ...ch the sensor head loosely to the door leaf with two of the nine supplied screws 3 Align the position sensor mounting plate with the appropriate mounting holes and securely fasten to the door leaf wit...

Page 4: ...he loop does not touch the door panel throughout the door travel 2 Once the ideal position is determined turn the screw in the back of the cover clockwise to secure the cover in place 1 Remove knockou...

Page 5: ...g Midpoint Two different frequencies can be set by adjusting Dipswitches 3 When two or more sensors are mounted close to each other they may interfere When that happens change Frequency Setting the Au...

Page 6: ...omplete in less than 5 seconds initiate setup again Door Status Sensor Status Operation Indicator Swing Side Approach Side Initial Setup door closed Yellow Blinking Solid Yellow Yellow Blinking Aproxi...

Page 7: ...CHECKING Operation Check Before leaving the site check ve items in the right table 1 7...

Page 8: ...s deep Improper voltage on red black wire of OC 904 Ensure positive voltage on red wire at hold open and 0 voltage at closed position Stalling caused by traffic just outside of swing path or objects n...

Page 9: ...TACT ACTIVATION OPERATION N O N C STALL RELAY CONTACT FUTURE DEVELOPMENT N O N C AUTO KNOWING ACT NOTE For Knowing Act application Connect purple wire to Activate output from push button The approach...

Page 10: ...not mounted flush on door Head may be resting on top of loop mounting bracket Reposition head flush on panel Improper threshold or swing area angle adjustment Set threshold and swing area angles at 5...