background image

 

Safety Instructions 

 

 

 

 

 

 

 

 

 

 

 

 

 

The optical devices used in this equipment are Hazard Level 1M. As required by IEC60825-1, the installer is responsible for insuring that the 
label depicted below is present in the restricted locations where this equipment is installed.  

 

This assembly contains parts sensitive to damage by electrostatic discharge (ESD). Use ESD precautionary procedures 
when touching, removing, or inserting parts or assemblies.  

 
 
The chassis into which this unit is installed must be housed in a properly rated NEMA enclosure.  

 
 
When this unit is operated in extremely elevated temperature conditions, it is possible for internal and external metal 
surfaces to become extremely hot. Care should be taken to insure this unit is installed in a restricted area where only 
properly trained service personnel have access to the unit.  

 

 

 

The safety information contained in this section, and on other pages of this manual, must be observed whenever this unit is operated, 
serviced, or repaired. Failure to comply with any precaution, warning, or instruction noted in the manual is in violation of the standards of 
design, manufacture, and intended use of the unit. TKH Security Solutions USA assumes no liability for the customer’s failure to comply 
with any of these safety requirements. 

 

RM-3

 

 

LASER RADIATION  

DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS (MAGNIFIERS)  

CLASS 1M LASER PRODUCT 

 

CAUTION:  

DISCONNECTED OPTICAL CONNECTORS MAY EMIT OPTICAL ENERGY.  

DO NOT VIEW BEAM WITH OPTICAL INSTRUMENTS (MAGNIFIERS) 

 

This product contains Class 1M lasers or LEDs.

   

• Class 1M laser product according to IEC60825-1:1993+A1+A2 
• 

CAUTION: Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure.          

• Precautions should be taken to prevent exposure to optical radiation when the unit is removed from its enclosure or when fiber is  
  disconnected from the unit. 
•Laser radiation may be present on a fiber connection to this unit even when the power has been removed from the unit. 
•This unit is intended for installation in locations where only trained service personnel have access to the fiber connections.

  

•The locations of all optical connections are listed in the Connection Locations and Function section of this manual. 
•Optical outputs and wavelengths are listed in the Specifications section of this manual.   

 

 

Hazard Level 1M 

The border shall be black and 
the background shall be yellow 

 

 

Summary of Contents for 9000 Series 9973-C

Page 1: ...Card with Four Port 10 100 Mb Ethernet Switch A pair of 9973 C cards transports a 10 base T Ethernet signal via the duplex high speed port available on many Optelecom video and data fiber transmissio...

Page 2: ......

Page 3: ...S curit 7 Fiber Information 8 External Wiring Information 8 Functional Description 9 9973 C Indicator Connector and Switch Locations 10 Set Up and Operation of the 9973 C 12 Typical Application of th...

Page 4: ...anufacture and intended use of the unit TKH Security Solutions USA assumes no liability for the customer s failure to comply with any of these safety requirements RM 3 LASER RADIATION DO NOT VIEW DIRE...

Page 5: ...est ndares de dise o fabricaci n y el uso destinado a la unidad TKH Security Solutions USA no asume ninguna responsabilidad si el cliente no cumple con alguno de estos reequisitos de seguridad RM 3 R...

Page 6: ...ions und Herstellungsstandards und erfolgt im gegensatz zum vorgesehenen Verwendungszweck dieser Einheit TKH Security Solutions USA bernimmt keine Haftung f r das Verabs umnis des Kunden diese Sicherh...

Page 7: ...cation et indication d usage de l appareil TKH Security Solutions USA n est pas responsable du non respect de ces consignes de s curit par le client RM 3 RAYONNEMENT LASER NE PAS REGARDER DIRECTEMENT...

Page 8: ...fiber across and then push it back This will put the dirt that was cleaned off back on again e Repeat the process on a dry folded tissue 3 When removing fibers always clean them when replacing them no...

Page 9: ...a 10 base T Ethernet link via the duplex high speed ports available on many video and data fiber transmission cards The 9973 C has a built in four port unmanaged 10 100 Ethernet switch The cards oper...

Page 10: ...r end but the far end is not receiving the signal from the local end If green Sync Loop the local receiver has a good signal and the remote receiver is reporting a good signal 2 HIGH SPEED PORT CONNEC...

Page 11: ...operating in Full Duplex mode In Half Duplex mode this LED will not be illuminated but will blink when there are collisions on the port Each port also has a green Link Activity LED that illuminates w...

Page 12: ...ty shielded UTP cable should be used If the length of the replacement cable length exceeds approximately 1 meter dipswitch S1 3 may need to be changed to the ON position This adjusts the timing on the...

Page 13: ...high speed port link for proper operation If the fiber and link status indicators on the video data host cards are normal follow the procedures below Check the high speed port status indicator on bot...

Page 14: ...Number of Slots 3 Card Name Model Number 4 Serial Number 5 Revision Number 6 Chronometer Value Cumulative Hours of Operation 7 Reset Cycles Cumulative Number of Power Cycles 8 Firmware Revision 9 Hig...

Page 15: ...ATA PORTS 1 AND 2 SPECIFICATIONS Connector Five position removable screw terminal Data Format RS232 3 wire RS422 2 or 4 wire RS485 2 or 4 wire Auto Baud up to 115 2 Kbps or Manchester Burle American D...

Page 16: ...ouda The Netherlands Telephone 31 182 592 333 Fax 31 182 592 123 E mail sales nl tkhsecurity com TKH Security Solutions USA 12920 Cloverleaf Center Drive Germantown Maryland 20874 USA Telephone 1 301...

Reviews: