Set Up and Operation of the 9973-C
Set up and operation of the 9973-C cards consists of setting the high-speed cable length switch if necessary,
installing the unit into a Series 9000 chassis, and connecting the Cat5 jumper cable from the high-speed port
on the optical communications card to the 9973-C.
The high-speed port connector cable should be a shielded non-crossover RJ45 Cat5 type cable. If the cable
supplied is not long enough for your application, a longer shielded cable may be used to connect the high-
speed port on the 9973-C to the high-speed port on the fiber optic host card. If this cable is longer than
approximately 1 meter, then dipswitch S1-3 may need to be reset. TKH Security USA recommends that the
supplied cable be used.
T
ABLE
1
–
D
IPSWITCH
1
Switch Position
Function
Factory Setting
1
Factory Use Only
N/A
2
Factory Use Only
N/A
3
Timing Adjustment Switch
OFF
Setting S1-3 Dipswitch
If the 9973-C is located further away from the high-speed port on the transmission card than the supplied
cable will allow, a number of considerations must be taken into account:
If it is necessary to replace the supplied cable, a high quality, shielded UTP cable should be used.
If the length of the replacement cable length exceeds approximately 1 meter, dipswitch S1-3 may need
to be changed to the ON position. This adjusts the timing on the high-speed port interface of the 9973-C
to allow for the timing loss created by the longer cable.
The dipswitch should only be changed if the
Ethernet link appears to be marginal in operation.
If the cable length exceeds 1 meter by a large factor, it may even be necessary to reset the switch back
to the original OFF position to adjust for an even further timing shift.
Dipswitch S1-3 compensates
only
for the timing between the 9973-C on which the switch is located and
fiber transmission card connected directly to that high-speed port. If, at the other end of the fiber link, a
long cable is used between the 9973-C there and it’s mating transmission card, the dipswitch on the
9973-C at that end of the link may need to be changed as well.
Operation
Operation of the 9973-C is straightforward. Once connected, the link should pass 10 Mb Ethernet signals. The
9973-C Ethernet four-port switch is a simple unmanaged 10/100 Mb Ethernet switch. The backplane of this
switch will support 100 Mb operation on each port. Even though the switch supports 10/100 Mb Ethernet, the
fiber part of the link between the switches is limited to a throughput of 10 Mbps.