9 Communication RS232, RS485 or USB 

12

 

Examples: 

Telegram = 21.05.2001 13:15 1.234Bar 

 

Characters   ASCII decimal 

2  

 

50 

1  

 

49 

 

46 

0  

 

48 

5  

 

53 

 

46 

2  

 

50 

0  

 

48 

0  

 

48 

1  

 

49 

SP    

32 

1  

 

49 

3  

 

51 

 

58 

1  

 

59 

5  

 

53 

SP    

32 

SP    

32 

1  

 

49 

 

44 

2  

 

50 

3  

 

51 

4  

 

52 

B  

 

66 

a  

 

97 

r  

 

114 

LF    

10 

CR    

13 

 

Example log with software hterm (not included): 

 

 

 
 

 

Summary of Contents for RM-32

Page 1: ...Radiometer RM 32 Operating instructions Version 1 4 Opsytec Dr Gr bel GmbH Am Hardtwald 6 8 D 76275 Ettlingen Phone 49 0 7243 9 47 83 50 Fax 49 0 7243 9 47 83 65info opsytec de...

Page 2: ...1 Sub D RS232 Adapter 15 12 Technical data 16 13 Radiation protection 16 2 Change history Version Modified from Changes 1 1 Paravia div adjustments 1 2 Paravia enhanced communication 1 3 Paravia Advan...

Page 3: ...er period of use we rec ommend that you send your sensor to us for inspection every 12 months We recalibrate the sensor if necessary we repair it A short time later your measuring equipment will be av...

Page 4: ...relation to two preselectable thresholds Two relays with switching contacts are activated simultaneously The relay functions can be triggered with a time delay The device is programmable and can contr...

Page 5: ...1 Controls and display The indicator lights up when the RM 32 is connected to mains voltage Fig 1 Control element RM32 SP1 When the button is pressed the SP1 pre alarm setpoint is dis played SP2 When...

Page 6: ...ensors with voltage output 0 10 V must be connected to the RM32 as follows Input 2 Sensor signal High wire color black Input 4 Sensor signal low wire colour grey GND for measurement 24V output galvani...

Page 7: ...nge values of the respective measuring routine Set desired value with arrow key Select next position with back arrow key Set desired value with arrow key When the desired value is entered Accept the v...

Page 8: ...ine 7 Set switching point SP1 pre alarm With this function the threshold SP1 pre alarm can be set in W m 2 The maximum val ue is 1000 Routine 8 Activate setpoint SP1 pre alarm This function routine ca...

Page 9: ...arm When the threshold value is reached the relay function is triggered with a time delay The time delay is proportional to the number of measuring cycles max 1999 cycles The measuring rate is 2 5 mea...

Page 10: ...e rounded The following settings are possi ble 000 last digit is set to 0 001 last digit is displayed 002 last digit is set to 0 2 4 6 8 005 last digit is set to 0 5 Routine 22 Number of measurements...

Page 11: ...ASCII code The sign of the measured value is sent as a minus for negative values otherwise as a space The transmission starts with the first character of the day and ends with LF line feed 10d 0Ah an...

Page 12: ...s Telegram 21 05 2001 13 15 1 234Bar Characters ASCII decimal 2 50 1 49 46 0 48 5 53 46 2 50 0 48 0 48 1 49 SP 32 1 49 3 51 58 1 59 5 53 SP 32 SP 32 1 49 44 2 50 3 51 4 52 B 66 a 97 r 114 LF 10 CR 13...

Page 13: ...ble and time setting of the RS232 000 Locked 001 Cycle time in min 002 Cycle time in sec preset Routine 27 Setting the baud rate of the serial interface 0 150 1 300 2 600 3 1200 4 2400 5 4800 Preset 6...

Page 14: ...minutes 4h 15min The number of transmission cycles also affects the transmission of the measured val ues when jumper JP4 is closed If set to 0 no transmission takes place Routine 35 Dimension of the...

Page 15: ...es B 66 in routine 35 a 97 in routine 36 r 114 in routine 37 m 109 in routine 35 A 65 in routine 36 32 in routine 37 Code table for routines 35 36 and 37 See ASCII special character table Jumper and s...

Page 16: ...e 10 to 40 C Humidity 80 non condensing 13 Radiation protection UV radiation is harmful to humans therefore observe the protective regulations when working Furthermore UVC radiation in particular has...

Reviews: