Buttons:
The buttons on the front panel control the water valves. You 
can see 4 buttons, but you can just press one button 
simultaneously.

DESRIPTION AND INSTALLATION

Cooling system: 
The cooling system consists of an aluminum block coolant with built-in stainless steel 
tubes.

Front panel: 

The

 front panel in dimension 430x330 made of plexiglas and 

is part of the doors. Under the front panel are dispensing 
buttons. On the inner of the main door is placed door which 
serve for commercial change, For opening unscrew latch on 
inner door. Commercial foil is placed between fixed plexiglas 
panel and white plastic panel. White plastic panel is placed 
in side slots and additionaly fixed with magnets (6x)

Drip tray:
The drip tray is made of stainless steel and adaptable to the 
heights of the glass.

Where the maximum permissible inclination is 2 degrees. When installing an air-cooled unit it 
is necessary to ensure that the unit has enough of free space, which is 0.4 m in front of the 
entrance and exit of the air. The unit should be placed on a flat and ventilated space away from 
the heat source, at least 7 cm away from the wall and 30 cm from the next unit. It is necessary 
to  look  around  device  to  ensure  free  air  circulation.  Make  sure  the  dispenser  is  vertical. 
Adjustment  is  made  with  adjustable  feet.  Inside  the  cabinet  you  will  find  additional 
equipment.

The device must be properly positioned on the surface:

Connect the water hose from the unit to the cold water supply. Let 
water running and check for leaks. Do not forget to put a gasket on it.

Connect the mains plug to the wall socket. (Compressor starts with 
cooling system and front panel lights up).

Summary of Contents for Juice Premix-Postmix

Page 1: ...d Gospodarska 5 42230 Ludbreg Hrvatska Croatia 385 42 819 183 E mail info oprema com Web www oprema com Original instructions v1 4 7 2018 Code 699195 Ure aji za hla enje i to enje JUICE PREMIX POSTMIX...

Page 2: ...ike koje nisu opisane u ovome Uputstvu Uputstvo se nalazi i na na oj web stranici www oprema com Uputstvo sadr i upute za instaliranje kori tenje i rukovanje ure ajima Ovo je uputstvo sastavni dio ure...

Page 3: ...sklju enizelektri nemre esvedozavr etkamonta e i pu tanja u probni rad Ure aj ne uklju ivati prije nego to miruje 2 sata na mjestu monta e Upozorenje Upozorenje Nemojte zatvarati otvore za provjetrava...

Page 4: ...iskrenja kada u blizini radi ure aj s radnom tvari R290 Ne smijete o tetiti rashladni krug Ne stavljajte eksplozivne spremnike aerosola sprejeve tube u ovaj ure aj ili oko njega Opasnost Opasnost Opas...

Page 5: ...Odlaganje ambala e 4 5 Uvjeti okoline 4 6 Postupci u slu aju neispravnosti 4 7 Postupci kod istakanja 5 Opis i Instalacija 5 1 Princip rada 6 Programiranje 7 i enje i odr avanje 6 1 i enje i odr avan...

Page 6: ...sploataciji 3 10 Compressor Radni obujam kompresora u cm 11 Vrsta i koli ina radne tvari u sistemu u gramima 12 Total eq Co2 koli ina stakleni kih plinova izra ena kao umno ak mase stakleni kih plinov...

Page 7: ...aja mo e se u potpunosti reciklirati Ambala udr ativandohvatadjece 3217 Odlaganje ambala e Postupci u slu aju neispravnosti Ve i dio tehni kih problema mo e biti lako rije en pomo u jednostavnih zahv...

Page 8: ...mje anje s koncentratom juice a u kona an produkt Ure aj je predvi en za to enje etiri napitka ili nekarbonizirane hladne vode Ure aj je spojen pomo u armiranog crijeva na priklju ak vode te kablom na...

Page 9: ...u bo ne utore reklame te je osigurana magnetima x6 Sabirnik Sabirnik je izra en od nehr aju eg elika i prilagodljiv visini a a Gdje je maksimalni dozvoljen nagib 2 stupnja Prilikom monta e ure aja sa...

Page 10: ...na ispravnu duljinu i stavite ga u koljenasti priklju ak na ejektoru Stavite a u pod izlazne cijevi slavine Nato ite a u soka pritiskom na tipku proizvoda Provjerite je li brix ejektora omjer mije anj...

Page 11: ...stakanje i tipku dr imo pritisnutu dulje od 0 8s aktivno je ru no istakanje i isto prestaje otpu tanjem tipke za istakanje Pode avanje parametara Pritiskom na tipke P i u trajanju barem 8 sekundi pokr...

Page 12: ...ijenjamo zadani parametar Jednako bi bilo da taj parametar promijenimo u modu programiranja Dozvola istakanja Omogu eno tipke svijetle bijelo i mogu e je istakanje Onemogu eno tipke ne svijetle i nije...

Page 13: ...page nr HR 13 HR Korisni ke upute programiranje...

Page 14: ...i za rukovanje sa zapaljivim tvarima To uklju uje znanje o alatima radu sa kompresorom i rashladnom jedinicom osnovnim zakonskim regulativama koje su primjenljive temjereoprezakojesepoduzimajuprilikom...

Page 15: ...laganje ovog proizvoda od strane korisnika uklju uje mogu nost primjene zakonskihsankcijauskladusva e imzakonskimpropisima Ure aji koji na sebi imaju oznaku punjeni su s radnom tvari R290 propan S obz...

Page 16: ...ormatoru je prekinut Pritezni magnetni ventil ne radi ispravno Vre ica sa sirupom je prazna Ejektor nije ispravno pode en Opskrba vodom isklju ena Regulator vode isklju en ili nije pode en Zavojnica j...

Page 17: ...magnetski ventil vode JG8 24V Electromagnetic water valve JG8 24V 15 343050 Ventilator komore 24V Cooling chamber fan 24V 16 650A696 Polica sirupa Syrup shelf 17 650A652 Izolirana rashladna komora Ins...

Page 18: ...page nr 18 Elektrosheme Electro schemes Stromschema Sch ma lectrique Schemi elettrici Esquemas el ctricas...

Page 19: ...19 Elektrosheme Electro schemes Stromschema Sch ma lectrique Schemi elettrici Esquemas el ctricas...

Page 20: ...page nr 20 Elektrosheme Electro schemes Stromschema Sch ma lectrique Schemi elettrici Esquemas el ctricas...

Page 21: ...differences which are not described in this Manual This manual contains instructions for installation use and handling with cooling units It is a part of the unit it has to be stored close to device...

Page 22: ...llation cooling unit must be disconnected from power supply until installationisfinished Beforeturningoncoolingunitmustbe2hoursonaplacewherewillbeinstalled Warning Warning Do not close ventilation ope...

Page 23: ...to avoid the danger Do not use open fire or potential sources of ignition when working with the R290 working unit nearby You may not damage the cooling circuit Do not put explosive aerosol containers...

Page 24: ...itions 4 6 Procedure in case of malfunction 4 7 Procedure for dispense 5 Description and installation 5 1 Working principle 6 Programming 7 Cleaning and maintenance 7 1 Cleaning and maintenance of sys...

Page 25: ...un current in Ampers during normal work 10 Compressor working volume of compressor in cm3 11 Type and quantity of refrigerant in the system in grams 12 Total EQ CO2 CO2 equivalent in tons 13 GWP Globa...

Page 26: ...t Do not incinerate packing parts or throw them to the environment Packing of this cooling unit can be recycled in total Keep packing material awayfromchildren 3217 PACKING POSTPONEMENT PROCEDURE IN C...

Page 27: ...inal product The appliance is designed for dispensing four drinks or uncarbonated cold water The appliance is connected with an armored hose to the water outlet and the cable to the electrical grid Th...

Page 28: ...drip tray is made of stainless steel and adaptable to the heights of the glass Where the maximum permissible inclination is 2 degrees When installing an air cooled unit it is necessary to ensure that...

Page 29: ...e and tubes Cut the hose to the correct length and put it in the elbow ejector connection Place the glass under the outlet pipe tap Fill the glass of juice by pressing the product button Make sure the...

Page 30: ...the key longer than 0 8s it is active manually and it also stops releasing the release key Setting parameters Pressing the P keys and for a period of at least 8 seconds a program mode is set for sett...

Page 31: ...would equally be that we change that parameter in the programming mode Dispensing permission Enabled The buttons are bright white and it is possible to highlight Disabled The buttons are not bright a...

Page 32: ...page nr EN 32 PROGRAMMING Settings...

Page 33: ...ems the service engineers must be trained to handle flammable substances This includes knowledge of tools work with compressor and refrigeration unit basic legal regulations that are applicable and pr...

Page 34: ...authorized disposal of this product by user could cause apply oflegalsanctionsinaccordancewithcurrentlegislation Coolers with mark are with refrigerant R290 propane Considering that cooler with this r...

Page 35: ...alves The transformer fuse has been interrupted The magnetic valve is not working properly The saucer is empty The ejector is not set correctly Water supply off The water regulator is off or not set T...

Page 36: ......

Reviews: