SUBMENU SETTINGS
1. SEt1
SEt1
is the value of
Relay1
turns active. (please refer to
tOut1
for duration of activation of Relay1).
•
Press
SET
button to enter the submenu When stay on
SEt1
.
•
Please refer to
"
enterring the CodE.
"
•
Press
UP/DOWN
buttons to set the value
•
Press
SET
button to shift the row on left.
•
After setting all the rows
Press
SET
button finally to save the value.
•
If u want to back menu
without saving
Press
RST
button
(ESCAPE).
•
Then equipment backs to main menu automatically.
2. SEt2
SEt2
is the value of
Relay2
turns active. (please refer to
tOut2
for duration of activation of Relay1).
•
Press
SET
button to enter the submenu When stay on
SEt2.
•
Please refer to
"
enterring the CodE.
"
•
Press
UP/DOWN
buttons to set the value
•
Press
SET
button to shift the row on left.
•
After setting all the rows
Press
SET
button finally to save the value.
•
If u want to back menu
without saving
Press
RST
button (ESCAPE)
•
Then equipment backs to main menu automatically.
3. CALH (CALIBRATION)
MODEL-CN5 is an Incremental Counter, as well as owing to scaled and calibrated, it is operated as a
Distance/Angel Measurement Equipment. Therefore,occured the LENGTH by Sensor movement
mechanically is matched the Value seen on the screen.
Sample
: When the Senor makes 5000 pulse movement
Mechaically,
In order to see 100.00 on the screen;
•
Move
the sensor to the designated position mechanically.
•
Press
RST
button to
zero
the counter display.
•
Move on
the sensor to make 5000 pulse on the display.
•
After the 5000 pulse occured
Press
SET
button to enter the main menu.
•
Press DOWN
button for 3 times and stay on
CALH
submenu.
•
Press
.
SET
button to enter the submenu.
•
Please refer to
pg.5
for enterring the CodE
•
Press
UP/DOWN
buttons and write “0100.00”.
•
After setting all the rows
Press
SET
button finally to
save
the value
•
Then equipment backs to main menu automatically.
•
Anymore,While the INCR mode is not used, for 5000 Pulse 100.00 is written on the screen.(Look at dSPtYP for INCR mode).
4. Poınt
This Parameter defines the Decimal Point.
•
Press
SET
button to enter the submenu When stay on
Poınt
.
•
Please refer to
"
enterring the CodE.
"
•
Press
UP/DOWN
buttons to shift the point.
•
Press
SET
button to save the point
•
If u want to back menu
without saving
Press
RST
button (ESCAPE).
•
Then equipment backs to main menu automatically.
5. toUt1
This parameter is used to keep in active durationof the RELAY1 in seconds(s).
Sample
: For 1 second
duration of RELAY1;
•
Press SET
button to enter the submenu When stay on
toUt1
.
•
Please refer to
"
enterring the CodE.
"
•
Press UP/DOWN
buttons to write
“
00001.0
”
on the display..
•
Press
SET
button to save.
•
If u want to back menu
without saving Press RST
button
(ESCAPE).
•
Then equipment backs to main menu automatically.
•
Write to display
“000000”
for duration continuosly
(HOLD).
6. toUt2
This parameter is used to keep in active durationof the RELAY2 in seconds(s). Sample: For 1.4 second
duration of RELAY2;
•
Press
SET
button to enter the submenu When stay on
toUt2
.
•
Please refer to
"
enterring the CodE.
"
•
Press UP/DOWN
buttons to write
“
00001.4
”
on the display..
•
Press
SET
button to save.
•
If u want to back menu
without saving
Press
RST
button
(ESCAPE).
•
Then equipment backs to main menu automatically.
•
Write to display
“
000000
”
for duration continuosly
(HOLD
).
7. PrSCL
This parameter is used as a Multiply Coefficient.In CALH Parameter setup,If the right value is not able
to been create mechanicly, the Calibration can been made by calculating the coefficient
Mathematically.Write it in space 0.001<PrSCL<99000 .
When the PrSCL value changed,the Previous Calibration data is deleted automaticaly.
•
Press
SET
button to enter the submenu When stay on
PrSCL.
•
Please refer to
"
enterring the CodE.
"
•
Press
UP/DOWN
buttons to write the calculated value.
•
Press
SET
button to save.
•
If u want to back menu
without saving
Press
RST
button (ESCAPE).
•
Then equipment backs to main menu automatically.
8. oUt
This parameter is used to define the Operation Types of the Realy1 and Relay2.please refer OUTPUT
TYPES
•
Press
SET
button to enter the submenu When stay on oUt.
•
Please refer to
"
enterring the CodE.
"
•
Press
UP/DOWN
buttons to write among
0-9
a number .
•
Press
SET
button to save.
•
If u want to back menu
without saving
Press
RST
button (ESCAPE).
•
Then equipment backs to main menu automatically.
9. oFFSEt
This Parameter is used to define the initial value of the Counter, When Pressed the RST button or an
external Z/Reset Pulse enabled.After this Resettlement the counter count forward or reverse from new
OFFSET value. The Default Counter value is zero
•
Press
SET
button to enter the submenu When stay on
oFFSEt.
•
Please refer to
"
enterring the CodE.
"
•
Press
UP/DOWN
buttons to write the ofset value.
•
Press
SET
button to save.
•
If u want to back menu
without saving
Press
RST
button (ESCAPE).
•
Then equipment backs to main menu automatically.
10. ınrST
This Parameter is used to define that, in which EDGE of External Z/Reset pulse, the Counter will
reset.Available 3 states
•
Press
SET
button to enter the submenu When stay on
ınrSt.
•
Please refer to
"
enterring the CodE.
"
•
Press
.
UP/DOWN
buttons and select one of this condition.
1.
norSt
:Disable Z/Reset.
2.
FALL
:Triggered by the falling edge of Z/Reset.
3. .
riSE
:Triggered by the rising edge of Z/Reset.
•
Press
SET
button to save.
•
If u want to back menu
without saving
Press
RST
button (ESCAPE).
•
Then equipment backs to main menu automatically.