Opkon OP-CN4 User Manual Download Page 3

   
       11. dSPtyP

 This parameter defines screen format.Available 3 states;

 •  

Press

  

SET

 

 button to enter the submenu When stay on 

dSPtyP

 • 

Please refer to 

"

 enterring the CodE.

"

 • 

Press 

UP/DOWN 

buttons and select one of this condition. 

 1. 

INC

: Screen shows INCREMENTAL Value.

 2. 

LEngtH

 : Screen shows MEASURING Value.

 

3. 

Both 

: By UP/DOWN  buttons can be see INC/Measuring values.

 •  

Press

 

SET

 

button to save.

 •  

If u want to back menu 

without saving

 

Press

 

RST

 

button (ESCAPE). 

 •  

Then equipment backs to main menu automatically.

  

     12. rECodE

 This Parameter is used to Change the Password(COdE).If the new Password is written 

“000000” 

then 

the Equipment do not ask any Password.

•  

Press

  

SET

 

 button to enter the submenu When stay on

 rECodE.

• 

Please refer to 

"

 enterring the CodE.

"

•  

Press 

 

UP/DOWN

 

buttons to write new CodE.

•  

Press

 

SET

 button to save.

•  

If u want to back menu 

without saving

 

Press

 

RST

 button (ESCAPE).

•  

Then equipment backs to main menu automatically.

     

  13. dAtA

 This parameter is used to HOLD or DELETE the last counter value in the Memory While the Equipment 
is switched down electricaly.Available 2 states;

•  

Press

  

SET

 

 button to enter the submenu When stay on

 dAtA

• 

Please refer to 

"

 enterring the CodE.

"

•  

Press 

UP/DOWN 

buttons and select one of this condition.

    

1. 

rEC

 : Counter value is stored on memory.When power turns on, counting value comes to screen.

    

2. 

CLear 

  : Counter value is not stored on memory.When power turns on counting value starts from 

        oFFSEt value.

 •  

Press

 

SET

 button to save.

                                                     •  

If u want to back menu 

without saving

 

Press

 

RST

 

button (ESCAPE). 

                                                     •

 Then equipment backs to main menu automatically.

 

       

 14. FCtory

 This Parameter helps to turn the factory settings.This parameter has a specific code.To turn the factory 
settings;

•  

Press

  

SET

 

 button to enter the submenu When stay on 

FCtory

•  

Press

 

UP/DOWN 

buttons to write “352947” on display.

•  

Press

 

SET

 

button.

trUe

 appears for 2 seconds.

•  

At the end of the 2 second,

 rEStrE(

ReStore) appears on the upper display ,and 

   

dEFS

(dEfaults) appears on the lower display.     

•  

Press

 

SET

 

to turn the factory settings.

•  

LodnG 

(loading) appears on the display for 3 second.The equipment turns the factory  

                                                    settings end of the 3 seconds.            

                                                   •  

If u want to back menu 

without turning the factory settings 

 

Press

 

RST

 button (ESCAPE). 

                                                   •  

Then equipment backs to main menu automatically.

15.

SoFt

This parameter shows the version of the software.

   

  ENTERING “CODE” 

    

 For Changing any Parameter, Stay on and 

Press

 

SET

  button.Program will ask “CodE” to enter.

     Entering the code is shown below;

•  

ENTER 

CodE

 by 

UP/DOWN

 

 buttons

•  

CodE 

 

is

 “

000001

 by factory settings.

•  

Pres SET button to enter the code.

•  

If the code is correct,for 2 seconds

 .TrUE

 will be shown on display.

•  

Then you do not need to re-enter code during programming.

•  

For changing CodE please refer submenu Settings.(11-rECodE).