background image

Therm-App 

MD™ Pro User Manual

  

 

Confidential Opgal Propriety                

      

         Page 

18-41

 of 

43

                         Document P/N UM-TAH00AQ-MD-PRO| Rev B

 

PRODUCT USAGE NOTICES 
 
Calibration 

The Product makes use of specific calibration data, which was prepared for it in the factory. It is possible that during prolonged field usage of the 
Product a deterioration of image will be noticed. In such cases, we recommend that you send in the device for re-calibration at the factory. Please 
contact our support team for further instructions.  
 

Accuracy 

The system requires 8-10 minutes to achieve steady state needed for the stated accuracy. For optimal performance we recommend waiting up to 
40 minutes and have at least 30 people pass in the field of view to create a statistical baseline. 

Disposal of electronic waste 

As  with  most  electronic  products,  this  equipment  must  be  disposed  of  in  an  environmentally  friendly  way,  and  in  accordance  with  existing 
regulations for electronic waste. 

Documentation updates 

Our manuals are updated from time to time, and we also issue product-critical notifications occasionally. 

16.

 

PRODUCT SAFETY INFORMATION 

WARNING 

Applicability: Class B Digital Product 

This Product has been tested and found to comply with the limits for a Class B digital Product, pursuant to Part 15 of the FCC Rules of the USA. 
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This Product generates, uses, 
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 
communications.  However,  there  is  no  guarantee  that interference  will  not  occur in  a  particular installation.  If  the  Product  does  cause  harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on, you are encouraged to try to correct 
the interference by one or more of the following measures: 

Reorient or relocate the receiving antenna. 

Increase the separation between the Product and receiver . 

Connect the Product into an outlet on a circuit different from that to which the receiver is connected. 

Consult the authorized reseller or an experienced radio/TV technician for help. 

WARNING 

Do not drop the Product or apply pressure on the IR lens as it may break. If the IR lens breaks, do not touch the broken pieces; the pieces can cause 
injury. 

WARNING 

Be careful when you touch the Product. Some parts of the Product can be sharp and could cause injury. 

WARNING 

Do not point the infrared detector (with or without the lens and lens cover) at intensive energy sources, for  example products that emit laser 
radiation, or the sun. This can have unwanted effects on the performance of the Product. It can also cause damage to the detector. 

WARNING  

Do not use the Product in a temperature environment higher than +50 degrees Celsius (+122 degrees Fahrenheit), unless specified otherwise in 
user documentation or technical data. High temperatures can cause damage to the detector. 

WARNING 

The Product is not sealed. Avoid exposure of the Product to water, rain or dust. 

WARNING 

Do not apply solvents or similar liquids to the detector or lens, as this can cause damage. 

WARNING  

Be careful when you clean the infrared lens. The lens has a delicate anti-reflective coating. Do not clean the lens too vigorously; this can damage 
the anti-reflective coating. 

Summary of Contents for Therm-App MD Pro

Page 1: ...rty only for the sole purpose stated herein and shall not be disclosed by the receiving party to any third party and shall not be duplicated used or disclosed in whole or in part for any purpose other...

Page 2: ...ture 7 8 7 2 Moisture on Skin 7 8 7 3 Angle 7 8 7 4 Steady State 7 8 7 5 Establishing a Baseline 7 8 8 Getting started 8 9 9 Browser Support 9 10 10 Access the device 10 10 11 First time turning on 11...

Page 3: ...RO Rev B 14 1 1 DATE and TIME 14 25 14 1 2 FILE UPLOAD 14 26 14 1 3 USERS 14 30 14 1 4 SUPPORT 14 31 15 Upgrading and Coupling a Therm App MD BASIC Camera to PRO version System Computer 15 32 16 Speci...

Page 4: ...n Before starting to use be sure to read the following To avoid usage problems and accidents first read the Safety Instruction and Handling Precautions Also read this user manual to ensure that you us...

Page 5: ...o not insert foreign objects or liquids into the product Do not use the system where flammable gases may be present This may cause an electric shock explosion or a fire If not in use do not leave the...

Page 6: ...ial micro USB input for a technician s use only Warning Do not use this port unless specifically instructed to do so by an OPGAL technical manager Micro SD A saving media option for future use current...

Page 7: ...asurement should not be solely or primarily relied upon to diagnose or exclude a diagnosis of COVID 19 or any other disease 2 Elevated body temperature in the context of use should be confirmed using...

Page 8: ...r conditioner If unavoidable allow the camera to obtain a new steady state before use normally 10 minutes 7 2 Moisture on Skin Make sure to wipe down or dry damp skin such as from rain or sweat 7 3 An...

Page 9: ...e mode by connecting the system s computer through a LAN to a remote PC or 2 Kiosk mode by connecting HDMI LCD monitor keyboard and mouse directly to the computer system Connect the system as it is su...

Page 10: ...indows 1 At the first you must set the same IP address subnet on your PC 2 In Windows 10 open the Network and Internet Settings 3 Select Ethernet and then open Change adapter options 4 Perform right m...

Page 11: ...n default settings 10 Create an administrator default username For example admin 11 Create a default password for the administrator user You can change the username and the password any time 12 It is...

Page 12: ...H00AQ MD PRO Rev B 11 First time turning on Each time after connecting the system to the power supply an initial warming up procedure is started and may take several minutes A live B W video and a Cam...

Page 13: ...ogin Logout change password menu 2 Address bar URL 3 Therm App MD Pro product brand name 4 Live View 5 HAMBURGER setting menu 6 Time Date Display 7 Quick access menu Voice Alarm Is Disable Voice Alarm...

Page 14: ...vailable only for admin user 1 Select the ROI REFERANCE icon 2 Press on ADD ROI REFERANCE button 3 A small yellow square X V ROI will appear 4 The Icon should be placed on a location which has a stabl...

Page 15: ...Therm App MD Pro User Manual Confidential Opgal Propriety Page 12 15 of 43 Document P N UM TAH00AQ MD PRO Rev B 12 2 Color Palette NONE GREEN INFERNO RAINBOW LAVA IRON VIRIDIS PSY...

Page 16: ...y Celsius Fahrenheit Kelvin Automatic background temperature Checking the box will perform Automatic default background temperature compensation Background temperature 25 100 c You can define the back...

Page 17: ...ential Opgal Propriety Page 13 17 of 43 Document P N UM TAH00AQ MD PRO Rev B 13 Main settings menu When pressing on the Hamburger icon on the left upper corner the left menu will pop up Pressing on TH...

Page 18: ...n the main menu Under the Network sub menu you will find the following tabs IP Addresses Section allows the user to change and set the IP addresses and DNS server addresses HTTPS Connection Section al...

Page 19: ...Obtain DNS servers automatically checkbox Press APPLY to save or CANCEL to dismiss the changes 13 1 3 Setting Manual DNS Server Addresses Please note This is applicable when synchronizing the time an...

Page 20: ...onnection Section Please Note This option is applicable when either selecting a self signed certificate or uploading an existing certificate Press on HTTPS Connection in the Settings page to expand th...

Page 21: ...v B 13 2 Certificates Tab Select Create Certificate Request for requesting a Secure Sockets Layer SSL certificate Fill in the following fields Common Name enter an IP address or system host name requi...

Page 22: ...e Self Signed Certificate for generating a self signed Secure Sockets Layer SSL certificate Fill in the following fields Common Name enter an IP address or system Host name required State or Province...

Page 23: ...nt P N UM TAH00AQ MD PRO Rev B Select Upload Certificate for loading an existing Secure Sockets Layer SSL certificate which originated from another source Press SELECT CERTIFICATE and browse to select...

Page 24: ...l support Press EXPORT SITE to export site defaults with constant IP address or with DHCP properties o A compressed file in tgzx format is downloaded to the computer s Download folder o Export DHCP si...

Page 25: ...Page 14 25 of 43 Document P N UM TAH00AQ MD PRO Rev B 14 1 1 DATE and TIME Select Synchronizing with the browser time to sync the system with browser time Select Synchronizing with NTP to sync the sys...

Page 26: ...ial Opgal Propriety Page 14 26 of 43 Document P N UM TAH00AQ MD PRO Rev B 14 1 2 FILE UPLOAD Press SELECT FILE button to update a new firmware and browse to the relevant firmware file location Select...

Page 27: ...Therm App MD Pro User Manual Confidential Opgal Propriety Page 14 27 of 43 Document P N UM TAH00AQ MD PRO Rev B Then press on the UPLOADFILE button to upload new version Look at the process BAR...

Page 28: ...Therm App MD Pro User Manual Confidential Opgal Propriety Page 14 28 of 43 Document P N UM TAH00AQ MD PRO Rev B Press RESTART to reboot the system...

Page 29: ...MD Pro User Manual Confidential Opgal Propriety Page 14 29 of 43 Document P N UM TAH00AQ MD PRO Rev B You can check if you are using the most updated version of the Therm App MD PRO by pressing on th...

Page 30: ...o User Manual Confidential Opgal Propriety Page 14 30 of 43 Document P N UM TAH00AQ MD PRO Rev B 14 1 3 USERS When entering the USERS tab as an admin you can manage users by adding removing and editin...

Page 31: ...Therm App MD Pro User Manual Confidential Opgal Propriety Page 14 31 of 43 Document P N UM TAH00AQ MD PRO Rev B 14 1 4 SUPPORT Special tab for Opgal technicians only...

Page 32: ...e following instructions 1 By using LAN cable connect the system computer via a LAN connection to the Internet connection via a router 2 Connect the camera to one of the four USB 3 ports 3 Connect a k...

Page 33: ...3 Document P N UM TAH00AQ MD PRO Rev B 8 The system will try to couple and calibrate the camera to the computer and the following screen will be displayed 9 After few minutes the system may display a...

Page 34: ...ev B 10 From the menu go to NETWORK SETTINGS IP ADDRESS and check the both checkboxes a Obtain IP address automatically b Obtain DNS Servers automatically 11 Press on the APPLY button 12 From the popu...

Page 35: ...e 15 35 of 43 Document P N UM TAH00AQ MD PRO Rev B 14 This process may take several minutes 15 After few minutes a live B W video and a Camera is warming up message will appear 16 Wait to Camera is wa...

Page 36: ...Hot cold threshold based pallets Manual and auto scale Measurement Settings Emissivity Reflected Temperature Statistical deep learning algorithm Color Palettes Rainbow Iron Vivid Grey Red Hot Blue Col...

Page 37: ...herm App MD Pro Application OS Support Linux compliance with Ubuntu 18 04 Display Interface HDMI 2 0 x1 Storage Device 16GB eMMC Micro SD Slot x1 Ethernet 10 100 1000Base TX x 1 I O USB 3 2 Gen 1 x 4...

Page 38: ...riety Page 17 38 of 43 Document P N UM TAH00AQ MD PRO Rev B Gross Weight 1 Kg 2 20 lb Net Weight 0 4 Kg 0 88 lb Operating Temperature 10 C to 40 C 14 F to 104 F Storage Temperature 45 C to 80 C 49 F t...

Page 39: ...l In order to make this extended warranty effective you must contact the authorized reseller from whom you purchased the Product or Opgal local service center and notify them about the production faul...

Page 40: ...t the prior written permission of Opgal Names and marks appearing on the Product are either registered trademarks or trademarks of Opgal and or its affiliates and or its licensors 11 OPEN SOURCE SOFTW...

Page 41: ...communications However there is no guarantee that interference will not occur in a particular installation If the Product does cause harmful interference to radio or television reception which can be...

Page 42: ...pneumatic tools and is set a at a level of pressure that is too high This can damage the detector and lens WARNING The device is designed to use 5V DC power supply only fed through its micro USB conne...

Page 43: ...on Email info opgal com Phone 972 4 9953903 Fax 972 4 9953900 http www opgal com P O Box 462 Industrial Area 5 Karmiel 2161401 ISRAEL All specifications are subject to change without notice Last Updat...

Reviews: