![OpenVox UC300 Series Quick Start Manual Download Page 6](http://html1.mh-extra.com/html/openvox/uc300-series/uc300-series_quick-start-manual_1640142006.webp)
UC300 Series Quick Start Guide
6
OpenVox Communication Co., LTD.
URL: www.openvox.cn
Password: pbx101~pbx110
UC300-A41EM port
fxs:port5 connects to analog telephony
fxo:port1
~
port4 connect to outside telephone connection
3.Device connection
FXS port connects to analog telephony, FXO connects to outside telephone
connection.
4. Access to device
Log in to the Web GUI
Step 1
Use a CAT5 cable to connect the device to the local network where the PC is
connected, or connect the device directly to the PC.
Step 2
Dial “**89” to obtain device IP address by an analog telephone, the device
defaults to a fixed IP address: 172.16.101.1
Step 3
Make sure that the PC and the device are on the same network segment.
Step 4
Enter the device IP address in the browser address bar (e.g. 192.168.2.218);
Step 5
You can enter the login interface for device configuration by selecting your role
and entering a password on the login interface. The default administrator
password is admin.
Getting Started