Figure 3-8-4 Call Duration Limitation Settings
The same as the algorithm for the single call duration limit, the total call time of the
port cannot exceed the product of the "Step" and the "Call Duration Limitation". The
Minimum Billing Time value must be less than the step size.
You can set a value for the Alarm Threshold. When the remaining call duration of the
port reaches the set value, the gateway will send alarm info to the designated phone.
You can also turn on enable auto reset, which can be selected from one day, one
week or one month. After the automatic reset time is reached, the remaining call
duration is reset to the set total call duration.
Figure 3-8-5 Auto Reset Settings
Table 3-8-1 Description of Call Duration Limit Settings
Options
Definition
Step
The value range of the step length is 1
-
999s. Multiplying the step
size by a single call time is to allow a single call duration.
Enable Single
Call Duration
Limit
The value of the single call duration limit, ranging from 1
-
999999.
The step size multiplied by the single talk time is the single call
duration.