background image

ACM5004-­‐LR   Quick   Start   (520083-­‐Rev   1.0)   

Page   3

   

   

 

Ø

 

Select 

Enable  Dial-Out,

  enter  the  carrier’s

  APN 

and  optionally  a 

Username

 

and 

Password

 

You may also need to use alternate DNS servers from those provided by your carrier: 

Ø

 

Check the 

Override Returned DNS Servers 

box and enter the IP of the DNS 

servers into the fields provided 

Note:

 

Your  cellular  carrier  may  have  provided  you  with  connection  details. 

However, you generally will only need to enter the APN and leave the other fields blank. 
If provided a PIN code you may need to use it to unlock the SIM card.

 

Ø

 

Click 

Apply

 and a data connection will be established with your cellular carrier 

Ø

 

Select 

Status: Statistics 

then the 

Failover & Out-of-Band 

tab 

Ø

 

Verify the 

Connection Status

 of 

Internal Cellular Modem

 is 

Connected

 and 

note your allocated 

IP Address 

(take note if it’s a private IP address) 

Ø

 

At any time you may view the cellular signal strength (

RSSI

) from the 

Cellular

 

tab  of  the 

Status:  Statistics 

page  –  an  RSSI  of  -100  dBm  and  less  is 

unacceptable

  coverage,  -99  to  -90  is 

weak  to  medium

  coverage,  -89  to  -70  is 

medium to strong

 coverage, -69 and greater is 

very strong

 coverage 

Note:

 

You can also see the connection status from the 

WWAN

 

LED. 

OFF is shown 

when in reset mode or not powered. When powered, it will go ON and while searching 

for  service  it  will  flash  off  briefly  every  5

 

sec.  Once  a 

data

 

connection  has  been 

established with your cellular carrier (i

.

e

.

, after an APN has been properly 

configured) the 

WWAN

 

LED will blink rapidly

.

 

If  you  have  been  allocated  a 

public  IP  address

,  you  can  now  access  the  appliance’s 

HTTPS and SSH services directly. If you have a 

dynamic public IP address

 that changes 

each  time  the  appliance  connects,  you  may  configure  the  appliance’s 

Dynamic  DNS

 

client in 

System: Dial

Internal Cellular Modem

If  you  have  been  allocated  a 

private  IP  address

  (i.e.  in  the  10.x.x.x,  100.64-127.x.x, 

172.16-31.x.x or 192.168.x.x range), direct remote access may not be possible.  Instead, 
use 

Call  Home

  or  VPN  to  establish  an  outbound  tunnel  to  an  Opengear  Lighthouse  or 

VPN server, to enable remote access over the tunnel.   

Note:

 

For a detailed overview of remote access alternatives to an appliance with 

a  private  IP  address,  refer  to  the 

Knowledge  Base  FAQ 

article 

Does  my  site  need  a 

public IP address for OOB or Failover access?

 

   

   

Reviews: