ACM5004-‐LR Quick Start (520083-‐Rev 1.0)
Page 2
Step 3 Set up appliance networking
The appliance’s default IP address is
192.168.0.1
(subnet mask
255.255.255.0
). With a
web browser on any computer that is connected to the appliance via
LAN USB 1
:
Ø
Enter
https://192.168.0.1
into the address bar
Ø
Log in using the default system user name
root
and the default password
default,
a
Welcome
screen listing the basic configuration steps is displayed
Note:
The computer must have an IP address in the same network range
(192.168.0.x) as the appliance. The appliance also has DHCP client enabled by default.
It will automatically accept any network IP address assigned by any DHCP server on
your network, and will then respond at both 192.168.0.1 and its DHCP address.
Ø
Select
Serial & Network: Users & Groups
and
Edit
the
Root User
. Enter and
confirm a new
Password
and click
Apply
Ø
Select
System: IP
then
Network Interface
(
LAN USB 1)
and check
DHCP
or
Static
for
Configuration Method
Note
:
The appliance’s firewall determines which protocols and services can be
used to access which ports and devices. By default only HTTPS and SSH access is
enabled to the appliance itself. Use the
Service Access
menu on
System: Services
to change settings for the appliance itself (and for connected serial ports).
Step 4 Connect the cellular modem
Note:
In OOB only mode the cellular modem may be always-on, or configured to
start and stop dynamically (e.g. in response to a loss of primary network connectivity).
For an overview of failover configurations, refer to the
Knowledge Base FAQ
article
Automatic failover to alternate broadband, cellular or dial-out Internet
connection
.
To set up an
always-on
cellular connection:
Ø
Select
System: Dial
then the
Internal Cellular Modem
tab