INSTRUCTIONS FOR USING THE BATTERIES IN UPOWER
The UPower batteries are based on LI-ION Technology. A feature of this technology is
that if the batteries are discharged until a certain point, they cannot be recharged again
and internally the battery is destroyed. This is inherent of the LI-ION technology.
In order to avoid that UPower batteries are not chargeable anymore we advise to use the
UPower batteries as follows.
If customers don’t follow these instructions than the
warranty on batteries is void
.
1.
If you have a failing battery, send the battery immediately to the nearest service
partner. If you fail to do this the warranty is void.
2.
If a battery is empty, charge the battery immediately.
3.
If batteries are not charged immediately the following discharge table will apply. If
batteries reach this point they are destroyed and cannot be charged again. The
following table shows in 2 different situations the number of days before the battery
is destroyed.
Battery
remaining
capacity
percentage
Approximately days to over-
discharge
(not install in UPower)
Approximately days to over-
discharge
(install in close down
UPower)
(no any device/cable connect
to UPower)
100%
1000 days
40 days
75%
750 days
37 days
50%
500 days
35 days
25%
250 days
32 days
10%
100 days
31 days
5%
50 days
30 days
0%
30 days
30 days