Ontech GSM Mini 9009 User Manual Download Page 1

 

 

Ontech GSM Mini 9009 
Ontech GSM Relay 9010

 

 

 

 
 
 
 
 
 

User Manual 

Summary of Contents for GSM Mini 9009

Page 1: ...Ontech GSM Mini 9009 Ontech GSM Relay 9010 User Manual...

Page 2: ...stions can be directed to support ondico se In this manual the Ontech GSM Mini 9009 will sometimes be called master unit and Ontech GSM Relay 9010 will be called slave unit SMS text will be shown with...

Page 3: ...tion by calling up 12 Turn off the alarm function with SMS 12 When an alarm is activated 13 Interpreting the SMS 13 Acknowledge an alarm 13 Temperature guard 14 Temperature 14 Status SMS 15 Power the...

Page 4: ...n NO and NC 25 Turn on off the alarm function 27 When an alarm is activated 27 Acknowledge an alarm 27 Functions 29 Push button 29 The lamp of the unit 29 Trubble shooting 30 Tip 31 Ontech GSM Mini 90...

Page 5: ...umbers The unit has a temperature guard that sends an alarm message if the temperature drops below 5 degrees Celsius The unit also reports the actual temperature Ontech GSM Relay 9010 is a slave unit...

Page 6: ...DE b In the field for telephone number enter your personal four digit number This number is the PINCODE you must enter each time you contact the unit 4 Create a send list for alarm a Create a new cont...

Page 7: ...ee below Replace the cover door 10 Connect the antenna to the unit 11 Insert the unit in a power jack The following happens a The green lamp starts flashing for about 45 seconds This indicates that th...

Page 8: ...e 1234 If the PIN code is correct the unit replies with a beep If it is not correct the call is disconnected Call again and try 4 Turn on the relay by pressing the following buttons 1 1 The unit repli...

Page 9: ...is your PIN code 3 Turn on the relay with timer function The relay can be turned on and you can set the number of hours you want it on before it switches to off between 1 and 99 h Send the following m...

Page 10: ...for powering external devices The connection cable has a connector in one end that fits in the jacket Change operation mode between NO and NC Under the back cover door you will find a DIP switch with...

Page 11: ...11 Suggestion for connection of alarm detector NO mode Suggestion for connection of alarm detector NC mode G B 12V A Sensor B Sensor A G B 12V A Sensor B Sensor A...

Page 12: ...2 The unit answers with a beep 3 Press your PIN code and then Example 1234 If the PIN code is correct the unit replies with a beep If it is not correct the call is disconnected Call again and try 4 Tu...

Page 13: ...e alarm input that still is activated In this example the SMS means that inputs 1a 1b and 3b has been activated since the last acknowledge and that input 3b still is activated Units 1 3 4 Indicates th...

Page 14: ...nowledge an alarm with SMS 1 Send an SMS to the unit with the following message ABCD 9 ABCD is your PIN code Temperature guard The unit can be set to automatic alarm when the temperature drops below 5...

Page 15: ...See page 20 Note that these inputs not can send an alarm again before the alarm has been acknowledged Inputs 1b Indicates the alarm input that still is activated In this example the SMS means that inp...

Page 16: ...Functions Commands These commands is for both SMS and called up connections with the unit Command What it means ABCD All programming and operations starts with your PIN code By pressing this button y...

Page 17: ...button 7 p q r or s Instead of writing the symbol you can use all letters on button 9 w x y or z Push button On the front of the unit there is a push button One push of the button switches the relay I...

Page 18: ...18 RED AND GREEN LAMP Flashing when starting up SIM card is missing or PIN code not deactivated See page 6 Be sure you have programmed the SIM card and not only the memory of the mobile phone...

Page 19: ...in power relay 230V 16A and two alarm inputs Up to seven different Ontech GSM Relay 9010 can be connected and individually operated by each Ontech GSM Mini 9009 The operating range is approx 30 meter...

Page 20: ...s has ID1 The slave units ID can be set from ID2 up to ID8 No unit may have ID0 When the slave unit is delivered factory setting is ID2 SETTING ID ON THE SLAVE UNIT WARNING During this operation the u...

Page 21: ...must be done on both master unit and all slave units in the system Which channel you choose is out of importance as long as the master and all slave units is set to the same channel Switches 2 3 4 an...

Page 22: ...r Unscrew the four screws on the back of the unit Remove the back cover gently Locate the DIP switch see below Switches 2 3 4 and 5 are used to set the radio channel Use a small screwdriver to change...

Page 23: ...ode is correct the unit replies with a beep If it is not correct the call is disconnected Call again and try 10 Turn on the relay by pressing the following buttons 1 N N is the ID of the unit The unit...

Page 24: ...is the ID of the unit 6 Turn on the relay with timer function The relay can be turned on and you can set the number of hours you want it on before it switches to off between 1 and 99 h Send the follow...

Page 25: ...jacket Change operation mode between NO and NC Under the back cover door you will find a DIP switch with 8 switches They are numbered from 1 8 Factory setting for switch no 1 is OFF This means that t...

Page 26: ...ode OFF NO and ON NC Use a small screwdriver to change position on desired switch Replace the back cover Replace the four screws Suggestion for connection of alarm detector NO mode Suggestion for conn...

Page 27: ...been acknowledge Inputs 1b Indicates the alarm input that still is activated In this example the SMS means that inputs 1a 1b and 3b has been activated since the last acknowledge and that input 1b sti...

Page 28: ...2 The unit answers with a beep 3 Press your PIN code and then Example 1234 If the PIN code is correct the unit replies with a beep If it is not correct the call is disconnected Call again and try 4 A...

Page 29: ...relay The lamp of the unit On the front of the unit there is a red lamp Lit The relay is turned on Not lit The relay is turned off Flashing The unit cannot communicate with the master unit Double fla...

Page 30: ...Different radio channels Check that the master unit and all slave units are set to the same radio channel See page 21 The master unit has no contact with an individual slave unit Out of radio range C...

Page 31: ...for a status SMS See page15 To long distance between master unit and slave unit A built in function in all slave units is a radio repeater This means that each slave unit increases the working range...

Page 32: ...ack up power 9 14 VDC Power consumtion Nominal 0 5 W Max 4 W Temperature range 20 C to 40 C Certified Compliance EMC LVD och RTTE directive Ontech GSM Relay 9010 Relay 230V 16A Short range radio Frequ...

Page 33: ...formity Ondico AB Datav gen 14A 436 32 Askim Sweden hereby declares that the products Ontech GSM Mini 9009 and Ontech GSM Relay 9010 is in conformity with the provisions of the Radio Teleterminal dire...

Page 34: ...34...

Page 35: ...35...

Page 36: ...36 www ondico se 15030_15035_IB_EN_081105...