POWER MONITORING 

INSTALLATION GUIDE

 

14724-D 

PAGE 9 

© 2011–2013 Veris Industries and Onset Computer Corporation  

 

Veris and the Veris “V” logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.  

Onset, HOBO, HOBOware, and HOBOlink are trademarks or registered trademarks of Onset Computer Corporation. 

UI MENU ABBREVIATIONS DEFINED 

The user can set the display mode to IEC or IEEE notation in the SETUP menu. 

Main Menu 

IEC 

IEEE 

Description 

D D 

Demand 

MAX M  Maximum 

Demand 

Present Real Power 

VAR 

Present Reactive Power 

VA 

Present Apparent Power 

A A Amps 
UAB, UBC, 
UAC 

VAB, VBC, 
VAC 

Voltage Line to Line 

VLN 

Voltage Line to Neutral 

PF PF 

Power 

Factor 

VLL 

Voltage Line to Line 

HZ HZ Frequency 
kSh 

kVAh 

Accumulated Apparent Energy 

kQh 

kVARh 

Accumulated Reactive Energy 

kPh 

kWh 

Accumulated Real Energy 

PLOSS PLOSS 

Phase 

Loss 

LOWPF 

LOWPF 

Low Power Factor Error 

F ERR 

F ERR 

Frequency Error 

I OVR 

I OVR 

Over Current 

V OVR 

V OVR 

Over Voltage 

PULSE 

PULSE 

kWh Pulse Output Overrun (configuration error) 

_PHASE 

_PHASE 

Summary Data for 1, 2, or 3 active phases 

ALERT ALERT Diagnostic Alert Status 
INFO INFO 

Unit 

Information 

MODEL MODEL 

Model 

Number 

OS OS 

Operating 

System 

RS RS 

Reset 

System 

SN SN Serial 

Number 

RESET RESET 

Reset 

Data 

PASWD 

PASWD 

Enter Reset or Setup Password 

ENERG 

ENERG 

Reset Energy Accumulators 

DEMND DEMND Reset 

Demand 

Maximums 

 

 

 

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for T-VER-E50B2

Page 1: ...Measurement Accuracy Real Power and Energy IEC 62053 22 Class 0 5S ANSI C12 20 0 5 Reactive Power and Energy IEC 62053 23 Class 2 2 Current 0 4 0 015 per C deviation from 25 C from 5 to 100 of range...

Page 2: ...e The LCD screen on the faceplate allows instant output viewing The meter is housed in a plastic enclosure suitable for installation on T35 DIN rail according to EN50022 The E50 can be mounted with an...

Page 3: ...the housing and the screw hole must be exposed on the outside of the housing 2 Use three 8 screws not supplied to mount the meter to the back of the enclosure See diagram of the underside of the meter...

Page 4: ...arallel wires for control power and voltage inputs The following symbols are used in the wiring diagrams on the following pages Symbol Description Voltage Disconnect Switch Fuse installer is responsib...

Page 5: ...ation WIRING DIAGRAMS CTs are not polarity sensitive No need to observe orientation Diagram 1 1 Phase Line to Neutral 2 Wire System 1 CT SYSTEM TYPE 1L 1n Diagram 2 1 Phase Line to Line 2 Wire System...

Page 6: ...C to 347 VAC UL or 300VAC CE Direct Connect Control Power DC Control PowerTransformers CPT Connection DC Control Power from 125VDC to 300VDC UL and CE max The Control Power Transformer may be wired L...

Page 7: ...mA 50 C The over current protective device must be rated for the short circuit current at the connection point Pulse outputs are only intended to be connected to non hazardous voltage circuits SELV or...

Page 8: ...SYSTM screen Use or to select the System Type see wiring diagrams on pages 9 10 b back to the S SYS screen 6 Optional to the S PT Set Potential Transformer screen If PTs are not used then skip this st...

Page 9: ...AC VAB VBC VAC Voltage Line to Line V VLN Voltage Line to Neutral PF PF Power Factor U VLL Voltage Line to Line HZ HZ Frequency kSh kVAh Accumulated Apparent Energy kQh kVARh Accumulated Reactive Ener...

Page 10: ...on Veris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademar...

Page 11: ...ris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademarks of...

Page 12: ...poration Veris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered tr...

Page 13: ...emarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademarks of Onset Computer Corporation USER...

Page 14: ...caling is listed below You can also enter custom scaling values in the following increments in both HOBOware and HOBOlink Refer to the HOBOware or HOBOlink help for more details Reactive Energy VARh 1...

Page 15: ...Usable Pulse Scale Setting for Wh VARh Key 1 Wh per pulse default 10 Wh per pulse 100 Wh per pulse 1 000 Wh per pulse 10 000 Wh per pulse 3 Phase Systems 2 Phase Systems Single Phase Systems Minimum U...

Page 16: ...eris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademarks o...

Reviews: