background image

onset

®

 

POWER MONITORING 

INSTALLATION GUIDE

 

14724-D 

PAGE 16 

© 2011–2013 Veris Industries and Onset Computer Corporation  

Veris and the Veris “V” logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.  

Onset, HOBO, HOBOware, and HOBOlink are trademarks or registered trademarks of Onset Computer Corporation. 

 

CHINA ROHS COMPLIANCE INFORMATION (EFUP TABLE)

 

 

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for T-VER-E50B2

Page 1: ...Measurement Accuracy Real Power and Energy IEC 62053 22 Class 0 5S ANSI C12 20 0 5 Reactive Power and Energy IEC 62053 23 Class 2 2 Current 0 4 0 015 per C deviation from 25 C from 5 to 100 of range...

Page 2: ...e The LCD screen on the faceplate allows instant output viewing The meter is housed in a plastic enclosure suitable for installation on T35 DIN rail according to EN50022 The E50 can be mounted with an...

Page 3: ...the housing and the screw hole must be exposed on the outside of the housing 2 Use three 8 screws not supplied to mount the meter to the back of the enclosure See diagram of the underside of the meter...

Page 4: ...arallel wires for control power and voltage inputs The following symbols are used in the wiring diagrams on the following pages Symbol Description Voltage Disconnect Switch Fuse installer is responsib...

Page 5: ...ation WIRING DIAGRAMS CTs are not polarity sensitive No need to observe orientation Diagram 1 1 Phase Line to Neutral 2 Wire System 1 CT SYSTEM TYPE 1L 1n Diagram 2 1 Phase Line to Line 2 Wire System...

Page 6: ...C to 347 VAC UL or 300VAC CE Direct Connect Control Power DC Control PowerTransformers CPT Connection DC Control Power from 125VDC to 300VDC UL and CE max The Control Power Transformer may be wired L...

Page 7: ...mA 50 C The over current protective device must be rated for the short circuit current at the connection point Pulse outputs are only intended to be connected to non hazardous voltage circuits SELV or...

Page 8: ...SYSTM screen Use or to select the System Type see wiring diagrams on pages 9 10 b back to the S SYS screen 6 Optional to the S PT Set Potential Transformer screen If PTs are not used then skip this st...

Page 9: ...AC VAB VBC VAC Voltage Line to Line V VLN Voltage Line to Neutral PF PF Power Factor U VLL Voltage Line to Line HZ HZ Frequency kSh kVAh Accumulated Apparent Energy kQh kVARh Accumulated Reactive Ener...

Page 10: ...on Veris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademar...

Page 11: ...ris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademarks of...

Page 12: ...poration Veris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered tr...

Page 13: ...emarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademarks of Onset Computer Corporation USER...

Page 14: ...caling is listed below You can also enter custom scaling values in the following increments in both HOBOware and HOBOlink Refer to the HOBOware or HOBOlink help for more details Reactive Energy VARh 1...

Page 15: ...Usable Pulse Scale Setting for Wh VARh Key 1 Wh per pulse default 10 Wh per pulse 100 Wh per pulse 1 000 Wh per pulse 10 000 Wh per pulse 3 Phase Systems 2 Phase Systems Single Phase Systems Minimum U...

Page 16: ...eris and the Veris V logo are trademarks or registered trademarks of Veris Industries L L C in the USA and or other countries Onset HOBO HOBOware and HOBOlink are trademarks or registered trademarks o...

Reviews: