background image

 

HOBO Temp/RH 3.5% Data Logger (UX100-003) Manual 

 

 

1-800-LOGGERS (564-4377) • 508-759-9500 

www.onsetcomp.com • [email protected] 

© 2013 Onset Computer Corporation. All rights reserved. Onset, HOBO, and HOBOware are 
trademarks or registered trademarks of Onset Computer Corporation. All other trademarks are the 
property of their respective companies. 

16209-E 

 

 

WARNING:

 Do not cut open, incinerate, heat above 85°C 

(185°F), or recharge the lithium battery. The battery may 
explode if the logger is exposed to extreme heat or conditions 
that could damage or destroy the battery case. Do not dispose 
of the logger or battery in fire. Do not expose the contents of 
the battery to water. Dispose of the battery according to local 
regulations for lithium batteries. 

HOBOware provides the option of recording the current battery 
voltage at each logging interval, which is disabled by default. 
Recording battery life at each logging interval takes up memory 
and therefore reduces logging duration. It is recommended you 
only record battery voltage for diagnostic purposes. 

Summary of Contents for HOBO UX100-003

Page 1: ...ion 0 07 at 25 C 77 F and 30 RH Response Time 43 seconds to 90 in airflow of 1 m s 2 2 mph Drift 1 per year typical Logger Logger Operating Range Logging 20 to 70 C 4 to 158 F 0 to 95 RH non condensin...

Page 2: ...to connect the logger to the computer or the HOBO U Shuttle via USB cable see Setting up the Logger and Reading Out the Logger LCD Screen This logger is equipped with an LCD screen that displays detai...

Page 3: ...ng the launch configurations onto the logger from HOBOware Make sure the USB cable is connected to both the logger and the computer and try launching again The logger has been stopped with HOBOware or...

Page 4: ...button for 1 second if you select this option 10 Click the Start button to launch the logger Disconnect the logger from the computer and deploy it using the mounting materials see Mounting the Logger...

Page 5: ...burst logging You also cannot select the Stop Logging option Never wrapping if burst logging is configured 2 In the Burst Logging window select a sensor In the example at right the temperature sensor...

Page 6: ...you want to calculate during logging Note that Average is automatically enabled when selecting Standard Deviation Important Statistics apply to all enabled sensors every selected statistic will be cal...

Page 7: ...that the pins are in the two holes on the board shown here enlarged and without the logger case for illustrative purposes 4 Snap the louvered door back into place in the logger 5 Check logger status i...

Page 8: ...e lithium battery The battery may explode if the logger is exposed to extreme heat or conditions that could damage or destroy the battery case Do not dispose of the logger or battery in fire Do not ex...

Reviews: