13
Piping Method
FP-4135 On-Board Volumetric Flow Detector
4.
Piping Method
Then, after reviewing the precautions, connect the FP-4135 On-Board Volumetric Flow Detector.
z
Do not remove the line filter from the detector.
The line filter is built into the FP-4135 On-Board Volumetric Flow Detector. So, it should not be removed from the detector.
The built-in line filter in the detector is designed to remove large debris in the piping connection, so use the other line
filters upstream of the liquid inlet of the detector.
z
Check the IN and OUT of the detector.
The detector has an inlet (IN) and an outlet (OUT) for the liquid. Recheck the inlet and the outlet when piping.
z
Recommendations on bypass valve installation
Installing a bypass valve in the piping as follows is recommended to maintain the measured system such as an engine,
release air pockets out of the piping, or to repair a detector malfunction.
OUT
IN
Bypass valve
FP-4135 On-Board Volumetric Flow Detector
(flow detecting part)
z
Make sure the power is disconnected (OFF) before starting piping.
Make sure the power of the Ono Sokki DF-2200 On-Board Flow Meter or the FM Series Digital Flowmeter are
disconnected (OFF).
To switch the power on/off, use the power switch of the Ono Sokki DF-2200 On-Board Flow Meter or the FM Series
Digital Flowmeter after connecting the FP-4135 On-Board Volumetric Flow Detector to the Ono Sokki DF-2200 On-
Board Flow Meter or the FM Series Digital Flowmeter with the flow signal cable, or use the power switch on the side of
Ono Sokki DF-2200 On-Board Flow Meter or the FM Series Digital Flowmeter.
z
Pay attention to how to wind the seal material.
Follow the instructions below to wind a Teflon seal tape on screws, for example when changing the joints.
•
A seal tape should be wound 2 to 2.5 times to a screw with the last 1 to 2 threads of a screw not tightened. The
number of times you need to wind may differ depend on the thickness of the seal tape.
•
When using liquid seal material, be careful not to leak the liquid material to piping.
•
The standard tightening torque for the joint R1/4 is 12 to 14 N
•m.